Debora Gil, Oriol Rodriguez-Leon, Petia Radeva, & Aura Hernandez-Sabate. (2007). "Assessing Artery Motion Compensation in IVUS " In Computer Analysis Of Images And Patterns (Vol. 4673, pp. 213–220). Lecture Notes in Computer Science. Heidelberg: Springerlink.
Abstract: Cardiac dynamics suppression is a main issue for visual improvement and computation of tissue mechanical properties in IntraVascular UltraSound (IVUS). Although in recent times several motion compensation techniques have arisen, there is a lack of objective evaluation of motion reduction in in vivo pullbacks. We consider that the assessment protocol deserves special attention for the sake of a clinical applicability as reliable as possible. Our work focuses on defining a quality measure and a validation protocol assessing IVUS motion compensation. On the grounds of continuum mechanics laws we introduce a novel score measuring motion reduction in in vivo sequences. Synthetic experiments validate the proposed score as measure of motion parameters accuracy; while results in in vivo pullbacks show its reliability in clinical cases.
Keywords: validation standards; quality measures; IVUS motion compensation; conservation laws; Fourier development
|
|
|
F.Guirado, Ana Ripoll, C.Roig, Aura Hernandez-Sabate, & Emilio Luque. (2006). "Exploiting Throughput for Pipeline Execution in Streaming Image Processing Applications " In UAB, E. N. W, & et al. (Eds.), Euro-Par 2006 Parallel Processing (Vol. 4128, pp. 1095–1105). Lecture Notes In Computer Science. Dresden, Germany (European Union): Springer-Verlag Berlin Heidelberg.
Abstract: There is a large range of image processing applications that act on an input sequence of image frames that are continuously received. Throughput is a key performance measure to be optimized when execu- ting them. In this paper we propose a new task replication methodology for optimizing throughput for an image processing application in the field of medicine. The results show that by applying the proposed methodo- logy we are able to achieve the desired throughput in all cases, in such a way that the input frames can be processed at any given rate.
Keywords: 12th International Euro–Par Conference
|
|
|
Patricia Marquez, Debora Gil, & Aura Hernandez-Sabate. (2012). "Error Analysis for Lucas-Kanade Based Schemes " In 9th International Conference on Image Analysis and Recognition (Vol. 7324, pp. 184–191). Lecture Notes in Computer Science. Springer-Verlag Berlin Heidelberg.
Abstract: Optical flow is a valuable tool for motion analysis in medical imaging sequences. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in medical sequences. This paper presents an error analysis of Lucas-Kanade schemes in terms of intrinsic design errors and numerical stability of the algorithm. Our analysis provides a confidence measure that is naturally correlated to the accuracy of the flow field. Our experiments show the higher predictive value of our confidence measure compared to existing measures.
Keywords: Optical flow, Confidence measure, Lucas-Kanade, Cardiac Magnetic Resonance
|
|