|
Enric Marti, Ferran Poveda, Antoni Gurgui, & Debora Gil. (2011). "Aprendizaje Basado en Proyectos en Ingeniería Informática. Resultados y reflexiones de seis años de experiencia ".
Abstract: In this workshop a 6 years experience in Project Based Learning (PBL) in Computer Graphics, Computer Engineering course at the Autonomous University of Barcelona (UAB) is presented. We use a Moodle environment suited to manage the documentation generated in PBL. The course is organized by means of two alternative routes: a classic itinerary of lectures and test-based evaluation and another with PBL. In the PBL itinerary we explain the organization in teamgroups, homework tutoring and monitoring and evaluation guidelines for students. We provide some of the work done by students, and the results of assessment surveys carried out to students during these years. We report the evolution of our PBL itinerary in terms of, both, organization and student surveys.
The workshop aims at discussing about on the advantages and disadvantages of using these active methodologies in technical degrees such as computer engineering, in order to debate about the most suitable way of organizing PBL and assessing students learning rate.
|
|
|
Jorge Bernal, Debora Gil, Carles Sanchez, & F. Javier Sanchez. (2014). "Discarding Non Informative Regions for Efficient Colonoscopy Image Analysis " In 1st MICCAI Workshop on Computer-Assisted and Robotic Endoscopy (Vol. 8899, pp. 1–10). Springer International Publishing.
Abstract: In this paper we present a novel polyp region segmentation method for colonoscopy videos. Our method uses valley information associated to polyp boundaries in order to provide an initial segmentation. This first segmentation is refined to eliminate boundary discontinuities caused by image artifacts or other elements of the scene. Experimental results over a publicly annotated database show that our method outperforms both general and specific segmentation methods by providing more accurate regions rich in polyp content. We also prove how image preprocessing is needed to improve final polyp region segmentation.
Keywords: Image Segmentation; Polyps, Colonoscopy; Valley Information; Energy Maps
|
|
|
Sergio Vera, Miguel Angel Gonzalez Ballester, & Debora Gil. (2015). "A Novel Cochlear Reference Frame Based On The Laplace Equation " In 29th international Congress and Exhibition on Computer Assisted Radiology and Surgery (Vol. 10, pp. 1–312).
|
|
|
Sonia Baeza, Debora Gil, I.Garcia Olive, M.Salcedo, J.Deportos, Carles Sanchez, et al. (2022). "A novel intelligent radiomic analysis of perfusion SPECT/CT images to optimize pulmonary embolism diagnosis in COVID-19 patients " . EJNMMI Physics, 9(1, Article 84), 1–17.
Abstract: Background: COVID-19 infection, especially in cases with pneumonia, is associated with a high rate of pulmonary embolism (PE). In patients with contraindications for CT pulmonary angiography (CTPA) or non-diagnostic CTPA, perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) is a diagnostic alternative. The goal of this study is to develop a radiomic diagnostic system to detect PE based only on the analysis of Q-SPECT/CT scans.
Methods: This radiomic diagnostic system is based on a local analysis of Q-SPECT/CT volumes that includes both CT and Q-SPECT values for each volume point. We present a combined approach that uses radiomic features extracted from each scan as input into a fully connected classifcation neural network that optimizes a weighted crossentropy loss trained to discriminate between three diferent types of image patterns (pixel sample level): healthy lungs (control group), PE and pneumonia. Four types of models using diferent confguration of parameters were tested.
Results: The proposed radiomic diagnostic system was trained on 20 patients (4,927 sets of samples of three types of image patterns) and validated in a group of 39 patients (4,410 sets of samples of three types of image patterns). In the training group, COVID-19 infection corresponded to 45% of the cases and 51.28% in the test group. In the test group, the best model for determining diferent types of image patterns with PE presented a sensitivity, specifcity, positive predictive value and negative predictive value of 75.1%, 98.2%, 88.9% and 95.4%, respectively. The best model for detecting
pneumonia presented a sensitivity, specifcity, positive predictive value and negative predictive value of 94.1%, 93.6%, 85.2% and 97.6%, respectively. The area under the curve (AUC) was 0.92 for PE and 0.91 for pneumonia. When the results obtained at the pixel sample level are aggregated into regions of interest, the sensitivity of the PE increases to 85%, and all metrics improve for pneumonia.
Conclusion: This radiomic diagnostic system was able to identify the diferent lung imaging patterns and is a frst step toward a comprehensive intelligent radiomic system to optimize the diagnosis of PE by Q-SPECT/CT.
|
|
|
Ferran Poveda, Jaume Garcia, Enric Marti, & Debora Gil. (2010). "Validation of the myocardial architecture in DT-MRI tractography " In Medical Image Computing in Catalunya: Graduate Student Workshop (pp. 29–30). Girona (Spain).
Abstract: Deep understanding of myocardial structure may help to link form and funcion of the heart unraveling crucial knowledge for medical and surgical clinical procedures and studies. In this work we introduce two visualization techniques based on DT-MRI streamlining able to decipher interesting properties of the architectural organization of the heart.
|
|
|
Carles Sanchez, Jorge Bernal, Debora Gil, & F. Javier Sanchez. (2013). "On-line lumen centre detection in gastrointestinal and respiratory endoscopy " In Klaus Miguel Angel and Drechsler Stefan and González Ballester Raj and Wesarg Cristina and Shekhar Marius George and Oyarzun Laura M. and L. Erdt (Ed.), Second International Workshop Clinical Image-Based Procedures (Vol. 8361, pp. 31–38). Springer International Publishing.
Abstract: We present in this paper a novel lumen centre detection for gastrointestinal and respiratory endoscopic images. The proposed method is based on the appearance and geometry of the lumen, which we defined as the darkest image region which centre is a hub of image gradients. Experimental results validated on the first public annotated gastro-respiratory database prove the reliability of the method for a wide range of images (with precision over 95 %).
Keywords: Lumen centre detection; Bronchoscopy; Colonoscopy
|
|
|
Aura Hernandez-Sabate, Petia Radeva, Antonio Tovar, & Debora Gil. (2006). "Vessel structures alignment by spectral analysis of ivus sequences " In Proc. of CVII, MICCAI Workshop (pp. 39–36). 1st International Wokshop on Computer Vision for Intravascular and Intracardiac Imaging (CVII’06). Copenhaguen (Denmark),.
Abstract: Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Usually, to overcome the image motion artifact ECG-gating and image-gated approaches are proposed, leading to slowing the pullback acquisition or disregarding part of IVUS data. In this paper, we argue that the image motion is due to 3-D vessel geometry as well as cardiac dynamics, and propose a dynamic model based on the tracking of an elliptical vessel approximation to recover the rigid transformation and align IVUS images without loosing any IVUS data. We report an extensive validation with synthetic simulated data and in vivo IVUS sequences of 30 patients achieving an average reduction of the image artifact of 97% in synthetic data and 79% in real-data. Our study shows that IVUS alignment improves longitudinal analysis of the IVUS data and is a necessary step towards accurate reconstruction and volumetric measurements of 3-D IVUS.
|
|
|
Oriol Rodriguez-Leor, A. Carol, H. Tizon, Eduard Fernandez-Nofrerias, J. Mauri, Vicente del Valle, et al. (2005)." Model estadístic-determinístic per la segmentació de l adventicia en imatges d ecografía intracoronaria" . Rev Societat Catalana Cardiologia, 5, 41.
|
|
|
Oriol Rodriguez-Leor, J. Mauri, Eduard Fernandez-Nofrerias, M. Gomez, Antonio Tovar, L. Cano, et al. (2002)." Ecografia Intracoronaria: Segmentacio Automatica de area de la llum" . Revista Societat Catalana de Cardiologia, 4(4), 42.
|
|
|
Enric Marti, Carme Julia, & Debora Gil. (2007)." PBL en la docencia de gráficos por computador" (Vol. 1). Valladolid.
|
|