|
Aura Hernandez-Sabate, Debora Gil, & Albert Teis. (2007). "How Do Conservation Laws Define a Motion Suppression Score in In-Vivo Ivus Sequences? " In Proc. IEEE Ultrasonics Symp (pp. 2231–2234).
Abstract: Evaluation of arterial tissue biomechanics for diagnosis and treatment of cardiovascular diseases is an active research field in the biomedical imaging processing area. IntraVascular UltraSound (IVUS) is a unique tool for such assessment since it reflects tissue morphology and deformation. A proper quantification and visualization of both properties is hindered by vessel structures misalignments introduced by cardiac dynamics. This has encouraged development of IVUS motion compensation techniques. However, there is a lack of an objective evaluation of motion reduction ensuring a reliable clinical application This work reports a novel score, the Conservation of Density Rate (CDR), for validation of motion compensation in in-vivo pullbacks. Synthetic experiments validate the proposed score as measure of motion parameters accuracy; while results in in vivo pullbacks show its reliability in clinical cases.
Keywords: validation standards; IVUS motion compensation; conservation laws.
|
|
|
Aura Hernandez-Sabate, Monica Mitiko, Sergio Shiguemi, & Debora Gil. (2010). "A validation protocol for assessing cardiac phase retrieval in IntraVascular UltraSound " In Computing in Cardiology (Vol. 37, pp. 899–902). IEEE.
Abstract: A good reliable approach to cardiac triggering is of utmost importance in obtaining accurate quantitative results of atherosclerotic plaque burden from the analysis of IntraVascular UltraSound. Although, in the last years, there has been an increase in research of methods for retrospective gating, there is no general consensus in a validation protocol. Many methods are based on quality assessment of longitudinal cuts appearance and those reporting quantitative numbers do not follow a standard protocol. Such heterogeneity in validation protocols makes faithful comparison across methods a difficult task. We propose a validation protocol based on the variability of the retrieved cardiac phase and explore the capability of several quality measures for quantifying such variability. An ideal detector, suitable for its application in clinical practice, should produce stable phases. That is, it should always sample the same cardiac cycle fraction. In this context, one should measure the variability (variance) of a candidate sampling with respect a ground truth (reference) sampling, since the variance would indicate how spread we are aiming a target. In order to quantify the deviation between the sampling and the ground truth, we have considered two quality scores reported in the literature: signed distance to the closest reference sample and distance to the right of each reference sample. We have also considered the residuals of the regression line of reference against candidate sampling. The performance of the measures has been explored on a set of synthetic samplings covering different cardiac cycle fractions and variabilities. From our simulations, we conclude that the metrics related to distances are sensitive to the shift considered while the residuals are robust against fraction and variabilities as far as one can establish a pair-wise correspondence between candidate and reference. We will further investigate the impact of false positive and negative detections in experimental data.
|
|
|
Aura Hernandez-Sabate, Petia Radeva, Antonio Tovar, & Debora Gil. (2006). "Vessel structures alignment by spectral analysis of ivus sequences " In Proc. of CVII, MICCAI Workshop (pp. 39–36). 1st International Wokshop on Computer Vision for Intravascular and Intracardiac Imaging (CVII’06). Copenhaguen (Denmark),.
Abstract: Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Usually, to overcome the image motion artifact ECG-gating and image-gated approaches are proposed, leading to slowing the pullback acquisition or disregarding part of IVUS data. In this paper, we argue that the image motion is due to 3-D vessel geometry as well as cardiac dynamics, and propose a dynamic model based on the tracking of an elliptical vessel approximation to recover the rigid transformation and align IVUS images without loosing any IVUS data. We report an extensive validation with synthetic simulated data and in vivo IVUS sequences of 30 patients achieving an average reduction of the image artifact of 97% in synthetic data and 79% in real-data. Our study shows that IVUS alignment improves longitudinal analysis of the IVUS data and is a necessary step towards accurate reconstruction and volumetric measurements of 3-D IVUS.
|
|
|
Aura Hernandez-Sabate, David Rotger, & Debora Gil. (2008). "Image-based ECG sampling of IVUS sequences " In Proc. IEEE Ultrasonics Symp. IUS 2008 (pp. 1330–1333).
Abstract: Longitudinal motion artifacts in IntraVascular UltraSound (IVUS) sequences hinders a properly 3D reconstruction and vessel measurements. Most of current techniques base on the ECG signal to obtain a gated pullback without the longitudinal artifact by using a specific hardware or the ECG signal itself. The potential of IVUS images processing for phase retrieval still remains little explored. In this paper, we present a fast forward image-based algorithm to approach ECG sampling. Inspired on the fact that maximum and minimum lumen areas are related to end-systole and end-diastole, our cardiac phase retrieval is based on the analysis of tissue density of mass along the sequence. The comparison between automatic and manual phase retrieval (0.07 ± 0.07 mm. of error) encourages a deep validation contrasting with ECG signals.
Keywords: Longitudinal Motion; Image-based ECG-gating; Fourier analysis
|
|
|
Aura Hernandez-Sabate, Debora Gil, J. Mauri, & Petia Radeva. (2006). "Reducing cardiac motion in IVUS sequences " In Proceeding of Computers in Cardiology (Vol. 33, pp. 685–688).
Abstract: Cardiac vessel displacement is a main artifact in IVUS sequences. It hinders visualization of the main structures in an appropriate orientation and alignment and affects extracting vessel measurements. In this paper, we present a novel approach for image sequence alignment based on spectral analysis, which removes rigid dynamics, preserving at the same time the vessel geometry. First, we suppress the translation by taking, for each frame, the center of mass of the image as origin of coordinates. In polar coordinates with such point as origin, the rotation appears as a horizontal displacement. The translation induces a phase shift in the Fourier coefficients of two consecutive polar images. We estimate the phase by adjusting a regression plane to the phases of the principal frequencies. Experiments show that the presented strategy suppress cardiac motion regardless of the acquisition device. 1.
|
|
|
Aura Hernandez-Sabate, Debora Gil, Petia Radeva, & E.N.Nofrerias. (2004). "Anisotropic processing of image structures for adventitia detection in intravascular ultrasound images " In Proc. Computers in Cardiology (Vol. 31, pp. 229–232). Chicago (USA).
Abstract: The adventitia layer appears as a weak edge in IVUS images with a non-uniform grey level, which difficulties its detection. In order to enhance edges, we apply an anisotropic filter that homogenizes the grey level along the image significant structures (ridges, valleys and edges). A standard edge detector applied to the filtered image yields a set of candidate points prone to be unconnected. The final model is obtained by interpolating the former line segments along the tangent direction to the level curves of the filtered image with an anisotropic contour closing technique based on functional extension principles
|
|
|
Enric Marti, Ferran Poveda, Antoni Gurgui, & Debora Gil. (2011). "Aprendizaje Basado en Proyectos en Ingeniería Informática. Resultados y reflexiones de seis años de experiencia ".
Abstract: In this workshop a 6 years experience in Project Based Learning (PBL) in Computer Graphics, Computer Engineering course at the Autonomous University of Barcelona (UAB) is presented. We use a Moodle environment suited to manage the documentation generated in PBL. The course is organized by means of two alternative routes: a classic itinerary of lectures and test-based evaluation and another with PBL. In the PBL itinerary we explain the organization in teamgroups, homework tutoring and monitoring and evaluation guidelines for students. We provide some of the work done by students, and the results of assessment surveys carried out to students during these years. We report the evolution of our PBL itinerary in terms of, both, organization and student surveys.
The workshop aims at discussing about on the advantages and disadvantages of using these active methodologies in technical degrees such as computer engineering, in order to debate about the most suitable way of organizing PBL and assessing students learning rate.
|
|
|
Enric Marti, Debora Gil, & Carme Julia. (2008)." Experiencia d aplicació de la metodología d aprenentatge per proyectes en assignatures d Enginyeria Informàtica per a una millor adaptació als crèdits ECTS i EEES" (IDES-UAB, & E. A. M.Enric Martinez, Eds.) (Vol. 1). UAB.
|
|
|
Enric Marti, Debora Gil, & Carme Julia. (2005). "A PBL experience in the teaching of Computer Graphics " In EUROGRAPHICS Proceedings (Vol. 5, pp. 95–103).
Abstract: Project-Based Learning (PBL) is an educational strategy to improve student’s learning capability that, in recent years, has had a progressive acceptance in undergraduate studies. This methodology is based on solving a problem or project in a student working group. In this way, PBL focuses on learning the necessary tools to correctly find a solution to given problems. Since the learning initiative is transferred to the student, the PBL method promotes students own abilities. This allows a better assessment of the true workload that carries out the student in the subject. It follows that the methodology conforms to the guidelines of the Bologna document, which quantifies the student workload in a subject by means of the European credit transfer system (ECTS). PBL is currently applied in undergraduate studies needing strong practical training such as medicine, nursing or law sciences. Although this is also the case in engineering studies, amazingly, few experiences have been reported. In this paper we propose to use PBL in the educational organization of the Computer Graphics subjects in the Computer Science degree. Our PBL project focuses in the development of a C++ graphical environment based on the OpenGL libraries for visualization and handling of different graphical objects. The starting point is a basic skeleton that already includes lighting functions, perspective projection with mouse interaction to change the point of view and three predefined objects. Students have to complete this skeleton by adding their own functions to solve the project. A total number of 10 projects have been proposed and successfully solved. The exercises range from human face rendering to articulated objects, such as robot arms or puppets. In the present paper we extensively report the statement and educational objectives for two of the projects: solar system visualization and a chess game. We report our earlier educational experience based on the standard classroom theoretical, problem and practice sessions and the reasons that motivated searching for other learning methods. We have mainly chosen PBL because it improves the student learning initiative. We have applied the PBL educational model since the beginning of the second semester. The student’s feedback increases in his interest for the subject. We present a comparative study of the teachers’ and students’ workload between PBL and the classic teaching approach, which suggests that the workload increase in PBL is not as high as it seems.
Keywords: project-based learning; computer graphics education; Open GL; rendering techniques; computer animation techniques; Graphics packages; Hierarchy and geometric transformations; Animation; Color; shading; shadowing and texture; fractals; hidden line/surface removal; Problem Based Learning
|
|
|
Enric Marti, Debora Gil, & Carme Julia. (2005). "Una experiència en PBL per a la docència de Gràfics per Computador ".
Abstract: En aquest article es presenta una experiència en ABP feta el curs 2004-05 en Gràfics per Computador 2, assignatura optativa de 3er curs d’Enginyeria Informàtica impartida a l’ETSE. En l’article s’explica l’organització docent abans d’ABP, basada en classes magistrals. Després es mostra l’organització en ABP i es quantifica en ECTS l’esforç de l’alumne en ambdues organitzacions. Essent conscient del diferent interès de l’alumnat per l’assignatura, se’ls hi ofereix dos itineraris: el de classes magistrals i d’ABP. Es mostren alguns resultats dels alumnes d’ABP i també les primeres enquestes realitzades als alumnes. S’exposen les conclusions en el primer any de l’experiència, plantejant temes de discussió. S’ha procurat que la proposta no desbordi l’esforç del professorat. Per això s’ofereix el doble itinerari, per a canalitzar per ABP els alumnes més interessats i permetre a la resta que realitzin el curs amb l’organització clàsica de l’assignatura: classes magistrals de teoria, problemes i pràctiques.
Keywords: Aprenentatge Basat en Projectes; Aprenentatge Basat en Problemes; Problem Based Learning; ECTS; EEES; Computer Graphics; OpenGL.
|
|