|
Records |
Links |
|
Author |
Jaume Garcia; Albert Andaluz; Debora Gil; Francesc Carreras |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
![goto web page (via DOI) doi](http://refbase.cvc.uab.es/img/doi.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Decoupled External Forces in a Predictor-Corrector Segmentation Scheme for LV Contours in Tagged MR Images |
Type |
Conference Article |
|
Year |
2010 |
Publication |
32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
4805-4808 |
|
|
Keywords |
|
|
|
Abstract |
Computation of functional regional scores requires proper identification of LV contours. On one hand, manual segmentation is robust, but it is time consuming and requires high expertise. On the other hand, the tag pattern in TMR sequences is a problem for automatic segmentation of LV boundaries. We propose a segmentation method based on a predictorcorrector (Active Contours – Shape Models) scheme. Special stress is put in the definition of the AC external forces. First, we introduce a semantic description of the LV that discriminates myocardial tissue by using texture and motion descriptors. Second, in order to ensure convergence regardless of the initial contour, the external energy is decoupled according to the orientation of the edges in the image potential. We have validated the model in terms of error in segmented contours and accuracy of regional clinical scores. |
|
|
Address |
Buenos Aires (Argentina) |
|
|
Corporate Author |
IEEE EMB |
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1557-170X |
ISBN |
978-1-4244-4123-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
EMBC |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number ![sorted by Call Number field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
IAM @ iam @ GAG2010 |
Serial |
1514 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Jaume Garcia; Ruth Aris; Guillaume Houzeaux; Manuel Vazquez |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
|
|
Title |
A Riemmanian approach to cardiac fiber architecture modelling |
Type |
Conference Article |
|
Year |
2009 |
Publication |
1st International Conference on Mathematical & Computational Biomedical Engineering |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
59-62 |
|
|
Keywords |
cardiac fiber architecture; diffusion tensor magnetic resonance imaging; differential (Rie- mannian) geometry. |
|
|
Abstract |
There is general consensus that myocardial fiber architecture should be modelled in order to fully understand the electromechanical properties of the Left Ventricle (LV). Diffusion Tensor magnetic resonance Imaging (DTI) is the reference image modality for rapid measurement of fiber orientations by means of the tensor principal eigenvectors. In this work, we present a mathematical framework for across subject comparison of the local geometry of the LV anatomy including the fiber architecture from the statistical analysis of DTI studies. We use concepts of differential geometry for defining a parametric domain suitable for statistical analysis of a low number of samples. We use Riemannian metrics to define a consistent computation of DTI principal eigenvector modes of variation. Our framework has been applied to build an atlas of the LV fiber architecture from 7 DTI normal canine hearts. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Swansea (UK) |
Editor |
Nithiarasu, R.L.R.V.L. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CMBE |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number ![sorted by Call Number field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
IAM @ iam @ FGA2009 |
Serial |
1520 |
|
Permanent link to this record |
|
|
|
|
Author |
Cristina Cañero; Petia Radeva; Oriol Pujol; Ricardo Toledo; Debora Gil; J. Saludes; Juan J. Villanueva; B. Garcia del Blanco; Josefina Mauri; Eduard Fernandez-Nofrerias; J.A. Gomez-Hospital; E. Iraculis; J. Comin; C. Quiles; F. Jara; A. Cequier; E.Esplugas |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
|
|
Title |
Three-dimensional reconstruction and quantification of the coronary tree using intravascular ultrasound images |
Type |
Conference Article |
|
Year |
1999 |
Publication |
Proceedings of International Conference on Computer in Cardiology (CIC´99) |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
In this paper we propose a new Computer Vision technique to reconstruct the vascular wall in space using a deformable model-based technique and compounding methods, based in biplane angiography and intravascular ultrasound data jicsion. It is also proposed a generalpurpose three-dimensional guided interpolation method. The three dimensional centerline of the vessel is reconstructed from geometrically corrected biplane angiographies using automatic segmentation methods and snakes. The IVUS image planes are located in the threedimensional space and correctly oriented. A led interpolation method based in B-SurJaces and snakes isused to fill the gaps among image planes |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CINC99 |
|
|
Notes |
MILAB;RV;IAM;ADAS;HuPBA |
Approved |
no |
|
|
Call Number ![sorted by Call Number field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
IAM @ iam @ CRP1999b |
Serial |
1492 |
|
Permanent link to this record |
|
|
|
|
Author |
Cristina Cañero; Petia Radeva; Oriol Pujol; Ricardo Toledo; Debora Gil; J. Saludes; Juan J. Villanueva; B. Garcia del Blanco; J. Mauri; E. Fernandez-Nofrerias; J.A. Gomez-Hospital; E. Iraculis; J. Comin; C. Quiles; F. Jara; A. Cequier; E. Esplugas |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
|
|
Title |
Optimal Stent Implantation: Three-dimensional Evaluation of the Mutual Position of Stent and Vessel via Intracoronary Ecography |
Type |
Conference Article |
|
Year |
1999 |
Publication |
Proceedings of International Conference on Computer in Cardiology (CIC´99) |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
We present a new automatic technique to visualize and quantify the mutual position between the stent and the vessel wall by considering their three-dimensional reconstruction. Two deformable generalized cylinders adapt to the image features in all IVUS planes corresponding to the vessel wall and the stent in order to reconstruct the boundaries of the stent and the vessel in space. The image features that characterize the stent and the vessel wall are determined in terms of edge and ridge image detectors taking into account the gray level of the image pixels. We show that the 30 reconstruction by deformable cylinders is accurate and robust due to the spatial data coherence in the considered volumetric IVUS image. The main clinic utility of the stent and vessel reconstruction by deformable’ cylinders consists of its possibility to visualize and to assess the optimal stent introduction. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB; RV; IAM; ADAS; HuPBA |
Approved |
no |
|
|
Call Number ![sorted by Call Number field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
IAM @ iam @ CRP1999a |
Serial |
1491 |
|
Permanent link to this record |
|
|
|
|
Author |
Francesc Carreras; Jaume Garcia; Debora Gil; Sandra Pujadas; Chi ho Lion; R.Suarez-Arias; R.Leta; Xavier Alomar; Manuel Ballester; Guillem Pons-Llados |
![goto web page url](http://refbase.cvc.uab.es/img/www.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Left ventricular torsion and longitudinal shortening: two fundamental components of myocardial mechanics assessed by tagged cine-MRI in normal subjects |
Type |
Journal Article |
|
Year |
2012 |
Publication |
International Journal of Cardiovascular Imaging |
Abbreviated Journal |
IJCI |
|
|
Volume |
28 |
Issue |
2 |
Pages |
273-284 |
|
|
Keywords |
Magnetic resonance imaging (MRI); Tagging MRI; Cardiac mechanics; Ventricular torsion |
|
|
Abstract |
Cardiac magnetic resonance imaging (Cardiac MRI) has become a gold standard diagnostic technique for the assessment of cardiac mechanics, allowing the non-invasive calculation of left ventric- ular long axis longitudinal shortening (LVLS) and absolute myocardial torsion (AMT) between basal and apical left ventricular slices, a movement directly related to the helicoidal anatomic disposition of the myocardial fibers. The aim of this study is to determine AMT and LVLS behaviour and normal values from a group of healthy subjects. A group of 21 healthy volunteers (15 males) (age: 23–55 y.o., mean:30.7 ± 7.5) were prospectively included in an obser- vational study by Cardiac MRI. Left ventricular rotation (degrees) was calculated by custom-made software (Harmonic Phase Flow) in consecutive LV short axis planes tagged cine-MRI sequences. AMT was determined from the difference between basal and apical planes LV rotations. LVLS (%) was determined from the LV longitudinal and horizontal axis cine-MRI images. All the 21 cases studied were interpretable, although in three cases the value of the LV apical rotation could not be determined. The mean rotation of the basal and apical planes at end-systole were -3.71° ± 0.84° and 6.73° ± 1.69° (n:18) respectively, resulting in a LV mean AMT of 10.48° ± 1.63° (n:18). End-systolic mean LVLS was 19.07 ± 2.71%. Cardiac MRI allows for the calculation of AMT and LVLS, fundamental functional components of the ventricular twist mechanics conditioned, in turn, by the anatomical helical layout of the myocardial fibers. These values provide complementary information about systolic ventricular function in relation to the traditional parameters used in daily practice. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Netherlands |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1569-5794 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number ![sorted by Call Number field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
IAM @ iam @ CGG2012 |
Serial |
1496 |
|
Permanent link to this record |
|
|
|
|
Author |
Albert Andaluz; Francesc Carreras; Cristina Santa Marta;Debora Gil |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Myocardial torsion estimation with Tagged-MRI in the OsiriX platform |
Type |
Conference Article |
|
Year |
2012 |
Publication |
ISBI Workshop on Open Source Medical Image Analysis software |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
Myocardial torsion (MT) plays a crucial role in the assessment of the functionality of the
left ventricle. For this purpose, the IAM group at the CVC has developed the Harmonic Phase Flow (HPF) plugin for the Osirix DICOM platform . We have validated its funcionalty on sequences acquired using different protocols and including healthy and pathological cases. Results show similar torsion trends for SPAMM acquisitions, with pathological cases introducing expected deviations from the ground truth. Finally, we provide the plugin free of charge at http://iam.cvc.uab.es |
|
|
Address |
Barcelona, Spain |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
IEEE |
Place of Publication |
|
Editor |
Wiro Niessen (Erasmus MC) and Marc Modat (UCL) |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ISBI |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number ![sorted by Call Number field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
IAM @ iam @ ACS2012 |
Serial |
1900 |
|
Permanent link to this record |
|
|
|
|
Author |
Albert Andaluz; Francesc Carreras; Debora Gil; Jaume Garcia |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Una aplicació amigable pel càlcul de indicadors clínics del ventricle esquerre |
Type |
Miscellaneous |
|
Year |
2010 |
Publication |
Forum Biocat 2010 |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
Lonja de Mar,Barcelona (Spain) |
|
|
Corporate Author |
CVC |
Thesis |
|
|
|
Publisher |
Biocat |
Place of Publication |
Barcelona |
Editor |
|
|
|
Language |
Catalan |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number ![sorted by Call Number field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
IAM @ iam @ ACG2010 |
Serial |
1483 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leor; Josefina Mauri; Eduard Fernandez-Nofrerias; Antonio Tovar; Vicente del Valle; Aura Hernandez-Sabate; Debora Gil; Petia Radeva |
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Utilizacion de la estructura de los campos vectoriales para la deteccion de la Adventicia en imagenes de Ecografia Intracoronaria |
Type |
Journal |
|
Year |
2004 |
Publication |
Revista Española de Cardiología |
Abbreviated Journal |
REC |
|
|
Volume |
57 |
Issue |
2 |
Pages |
100 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
SEC |
|
|
Notes |
MILAB;IAM |
Approved |
no |
|
|
Call Number ![sorted by Call Number field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
BCNPCL @ bcnpcl @ RMF2004 |
Serial |
566 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leor; Josefina Mauri; Eduard Fernandez-Nofrerias; M. Gomez; Antonio Tovar; L. Cano; C. Diego; Carme Julia; Vicente del Valle; Debora Gil; Petia Radeva |
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Ecografia Intracoronaria: Segmentacio Automatica de area de la llum |
Type |
Journal |
|
Year |
2002 |
Publication |
Revista Societat Catalana de Cardiologia |
Abbreviated Journal |
|
|
|
Volume |
4 |
Issue |
4 |
Pages |
42 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
Barcelona |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
XIVe Congres de la Societat Catalana de Cardiologia |
|
|
Notes |
MILAB;IAM |
Approved |
no |
|
|
Call Number ![sorted by Call Number field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
BCNPCL @ bcnpcl @ RMF2002 |
Serial |
435 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Petia Radeva |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
A Regularized Curvature Flow Designed for a Selective Shape Restoration |
Type |
Journal Article |
|
Year |
2004 |
Publication |
IEEE Transactions on Image Processing |
Abbreviated Journal |
|
|
|
Volume |
13 |
Issue |
|
Pages |
1444–1458 |
|
|
Keywords |
Geometric flows, nonlinear filtering, shape recovery. |
|
|
Abstract |
Among all filtering techniques, those based exclu- sively on image level sets (geometric flows) have proven to be the less sensitive to the nature of noise and the most contrast preserving. A common feature to existent curvature flows is that they penalize high curvature, regardless of the curve regularity. This constitutes a major drawback since curvature extreme values are standard descriptors of the contour geometry. We argue that an operator designed with shape recovery purposes should include a term penalizing irregularity in the curvature rather than its magnitude. To this purpose, we present a novel geometric flow that includes a function that measures the degree of local irregularity present in the curve. A main advantage is that it achieves non-trivial steady states representing a smooth model of level curves in a noisy image. Performance of our approach is compared to classical filtering techniques in terms of quality in the restored image/shape and asymptotic behavior. We empirically prove that our approach is the technique that achieves the best compromise between image quality and evolution stabilization. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number ![sorted by Call Number field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
BCNPCL @ bcnpcl @ GiR2004b |
Serial |
491 |
|
Permanent link to this record |