|   | 
Details
   web
Records
Author David Roche; Debora Gil; Jesus Giraldo
Title Assessing agonist efficacy in an uncertain Em world Type Conference Article
Year 2012 Publication 40th Keystone Symposia on mollecular and celular biology Abbreviated Journal
Volume Issue Pages 79
Keywords
Abstract The operational model of agonism has been widely used for the analysis of agonist action since its formulation in 1983. The model includes the Em parameter, which is defined as the maximum response of the system. The methods for Em estimation provide Em values not significantly higher than the maximum responses achieved by full agonists. However, it has been found that that some classes of compounds as, for instance, superagonists and positive allosteric modulators can increase the full agonist maximum response, implying upper limits for Em and thereby posing doubts on the validity of Em estimates. Because of the correlation between Em and operational efficacy, τ, wrong Em estimates will yield wrong τ estimates.
In this presentation, the operational model of agonism and various methods for the simulation of allosteric modulation will be analyzed. Alternatives for curve fitting will be presented and discussed.
Address Fairmont Banff Springs, Banff, Alberta, Canada
Corporate Author Keystone Symposia Thesis
Publisher Keystone Symposia Place of Publication Editor A. Christopoulus and M. Bouvier
Language english Summary Language english Original Title
Series Editor Keystone Symposia Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference KSMCB
Notes (up) IAM Approved no
Call Number IAM @ iam @ RGG2012 Serial 1855
Permanent link to this record
 

 
Author Albert Andaluz
Title Harmonic Phase Flow: User's guide Type Manual
Year 2012 Publication CVC Abbreviated Journal
Volume Issue Pages
Keywords
Abstract HPF is a plugin for the computation of clinical scores under Osirix.
This manual provides a basic guide for experienced clinical staff. Chapter 1 provides the theoretical background in which this plugin is based.
Next, in chapter 2 we provide basic instructions for installing and uninstalling this plugin. chapter 3we shows a step-by-step scenario to compute clinical scores from tagged-MRI images with HPF. Finally, in chapter 4 we provide a quick guide for plugin developers
Address Bellaterra, Barcelona (Spain)
Corporate Author Computer Vision Center Thesis
Publisher CVC Place of Publication Barcelona Editor
Language english Summary Language english Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes (up) IAM Approved no
Call Number IAM @ iam @ And2012 Serial 1863
Permanent link to this record
 

 
Author Patricia Marquez; Debora Gil ; Aura Hernandez-Sabate
Title Error Analysis for Lucas-Kanade Based Schemes Type Conference Article
Year 2012 Publication 9th International Conference on Image Analysis and Recognition Abbreviated Journal
Volume 7324 Issue I Pages 184-191
Keywords Optical flow, Confidence measure, Lucas-Kanade, Cardiac Magnetic Resonance
Abstract Optical flow is a valuable tool for motion analysis in medical imaging sequences. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in medical sequences. This paper presents an error analysis of Lucas-Kanade schemes in terms of intrinsic design errors and numerical stability of the algorithm. Our analysis provides a confidence measure that is naturally correlated to the accuracy of the flow field. Our experiments show the higher predictive value of our confidence measure compared to existing measures.
Address Aveiro, Portugal
Corporate Author Thesis
Publisher Springer-Verlag Berlin Heidelberg Place of Publication Editor
Language english Summary Language Original Title
Series Editor Campilho, Aurélio and Kamel, Mohamed Series Title Lecture Notes in Computer Science Abbreviated Series Title LNCS
Series Volume Series Issue Edition
ISSN 0302-9743 ISBN 978-3-642-31294-6 Medium
Area Expedition Conference ICIAR
Notes (up) IAM Approved no
Call Number IAM @ iam @ MGH2012a Serial 1899
Permanent link to this record
 

 
Author Patricia Marquez; Debora Gil; Aura Hernandez-Sabate
Title A Confidence Measure for Assessing Optical Flow Accuracy in the Absence of Ground Truth Type Conference Article
Year 2011 Publication IEEE International Conference on Computer Vision – Workshops Abbreviated Journal
Volume Issue Pages 2042-2049
Keywords IEEE International Conference on Computer Vision – Workshops
Abstract Optical flow is a valuable tool for motion analysis in autonomous navigation systems. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in real world sequences. This paper introduces a measure of optical flow accuracy for Lucas-Kanade based flows in terms of the numerical stability of the data-term. We call this measure optical flow condition number. A statistical analysis over ground-truth data show a good statistical correlation between the condition number and optical flow error. Experiments on driving sequences illustrate its potential for autonomous navigation systems.
Address
Corporate Author Thesis
Publisher IEEE Place of Publication Barcelona (Spain) Editor
Language English Summary Language English Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference ICCVW
Notes (up) IAM; ADAS Approved no
Call Number IAM @ iam @ MGH2011 Serial 1682
Permanent link to this record
 

 
Author Aura Hernandez-Sabate; Debora Gil
Title The Benefits of IVUS Dynamics for Retrieving Stable Models of Arteries Type Book Chapter
Year 2012 Publication Intravascular Ultrasound Abbreviated Journal
Volume Issue Pages 185-206
Keywords
Abstract
Address
Corporate Author Thesis
Publisher Intech Place of Publication Editor Yasuhiro Honda
Language English Summary Language english Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN 978-953-307-900-4 Medium
Area Expedition Conference
Notes (up) IAM; ADAS Approved no
Call Number IAM @ iam @ HeG2012 Serial 1684
Permanent link to this record
 

 
Author Sergio Vera; Debora Gil; Antonio Lopez; Miguel Angel Gonzalez Ballester
Title Multilocal Creaseness Measure Type Journal
Year 2012 Publication The Insight Journal Abbreviated Journal IJ
Volume Issue Pages
Keywords Ridges, Valley, Creaseness, Structure Tensor, Skeleton,
Abstract This document describes the implementation using the Insight Toolkit of an algorithm for detecting creases (ridges and valleys) in N-dimensional images, based on the Local Structure Tensor of the image. In addition to the filter used to calculate the creaseness image, a filter for the computation of the structure tensor is also included in this submission.
Address
Corporate Author Alma IT Systems Thesis
Publisher Place of Publication Editor
Language english Summary Language english Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes (up) IAM;ADAS; Approved no
Call Number IAM @ iam @ VGL2012 Serial 1840
Permanent link to this record
 

 
Author Sergio Vera; Debora Gil; Agnes Borras; F. Javier Sanchez; Frederic Perez; Marius G. Linguraru; Miguel Angel Gonzalez Ballester
Title Computation and Evaluation of Medial Surfaces for Shape Representation of Abdominal Organs Type Book Chapter
Year 2012 Publication Workshop on Computational and Clinical Applications in Abdominal Imaging Abbreviated Journal
Volume 7029 Issue Pages 223–230
Keywords medial manifolds, abdomen.
Abstract Medial representations are powerful tools for describing and parameterizing the volumetric shape of anatomical structures. Existing methods show excellent results when applied to 2D
objects, but their quality drops across dimensions. This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial
manifolds that avoid degenerated medial axis segments; second, we introduce an energy based method which performs independently of the dimension. We evaluate quantitatively the performance of our
method with respect to existing approaches, by applying them to synthetic shapes of known medial geometry. Finally, we show results on shape representation of multiple abdominal organs,
exploring the use of medial manifolds for the representation of multi-organ relations.
Address Toronto; Canada;
Corporate Author Thesis
Publisher Springer Link Place of Publication Berlin Editor H. Yoshida et al
Language English Summary Language English Original Title
Series Editor Series Title Lecture Notes in Computer Science Abbreviated Series Title LNCS
Series Volume Series Issue Edition
ISSN 0302-9743 ISBN 978-3-642-28556-1 Medium
Area Expedition Conference ABDI
Notes (up) IAM;MV Approved no
Call Number IAM @ iam @ VGB2012 Serial 1834
Permanent link to this record
 

 
Author Carles Sanchez
Title Tracheal ring detection in bronchoscopy Type Report
Year 2011 Publication CVC Technical Report Abbreviated Journal
Volume 168 Issue Pages
Keywords Bronchoscopy, tracheal ring, segmentation
Abstract Endoscopy is the process in which a camera is introduced inside a human.
Given that endoscopy provides realistic images (in contrast to other modalities) and allows non-invase minimal intervention procedures (which can aid in diagnosis and surgical interventions), its use has spreaded during last decades.
In this project we will focus on bronchoscopic procedures, during which the camera is introduced through the trachea in order to have a diagnostic of the patient. The diagnostic interventions are focused on: degree of stenosis (reduction in tracheal area), prosthesis or early diagnosis of tumors. In the first case, assessment of the luminal area and the calculation of the diameters of the tracheal rings are required. A main limitation is that all the process is done by hand,
which means that the doctor takes all the measurements and decisions just by looking at the screen. As far as we know there is no computational framework for helping the doctors in the diagnosis.
This project will consist of analysing bronchoscopic videos in order to extract useful information for the diagnostic of the degree of stenosis. In particular we will focus on segmentation of the tracheal rings. As a result of this project several strategies (for detecting tracheal rings) had been implemented in order to compare their performance.
Address
Corporate Author Thesis Master's thesis
Publisher Place of Publication Editor Debora Gil, F.Javier Sanchez
Language english Summary Language english Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes (up) IAM;MV Approved no
Call Number IAM @ iam @ San2011 Serial 1841
Permanent link to this record