|
Frederic Sampedro, Sergio Escalera, & Anna Puig. (2014). Iterative Multiclass Multiscale Stacked Sequential Learning: definition and application to medical volume segmentation. PRL - Pattern Recognition Letters, 46, 1–10.
Abstract: In this work we present the iterative multi-class multi-scale stacked sequential learning framework (IMMSSL), a novel learning scheme that is particularly suited for medical volume segmentation applications. This model exploits the inherent voxel contextual information of the structures of interest in order to improve its segmentation performance results. Without any feature set or learning algorithm prior assumption, the proposed scheme directly seeks to learn the contextual properties of a region from the predicted classifications of previous classifiers within an iterative scheme. Performance results regarding segmentation accuracy in three two-class and multi-class medical volume datasets show a significant improvement with respect to state of the art alternatives. Due to its easiness of implementation and its independence of feature space and learning algorithm, the presented machine learning framework could be taken into consideration as a first choice in complex volume segmentation scenarios.
Keywords: Machine learning; Sequential learning; Multi-class problems; Contextual learning; Medical volume segmentation
|
|
|
Frederic Sampedro, Sergio Escalera, Anna Domenech, & Ignasi Carrio. (2015). Automatic Tumor Volume Segmentation in Whole-Body PET/CT Scans: A Supervised Learning Approach Source. JMIHI - Journal of Medical Imaging and Health Informatics, 5(2), 192–201.
Abstract: Whole-body 3D PET/CT tumoral volume segmentation provides relevant diagnostic and prognostic information in clinical oncology and nuclear medicine. Carrying out this procedure manually by a medical expert is time consuming and suffers from inter- and intra-observer variabilities. In this paper, a completely automatic approach to this task is presented. First, the problem is stated and described both in clinical and technological terms. Then, a novel supervised learning segmentation framework is introduced. The segmentation by learning approach is defined within a Cascade of Adaboost classifiers and a 3D contextual proposal of Multiscale Stacked Sequential Learning. Segmentation accuracy results on 200 Breast Cancer whole body PET/CT volumes show mean 49% sensitivity, 99.993% specificity and 39% Jaccard overlap Index, which represent good performance results both at the clinical and technological level.
Keywords: CONTEXTUAL CLASSIFICATION; PET/CT; SUPERVISED LEARNING; TUMOR SEGMENTATION; WHOLE BODY
|
|
|
Frederic Sampedro, Sergio Escalera, Anna Domenech, & Ignasi Carrio. (2014). A computational framework for cancer response assessment based on oncological PET-CT scans. CBM - Computers in Biology and Medicine, 55, 92–99.
Abstract: In this work we present a comprehensive computational framework to help in the clinical assessment of cancer response from a pair of time consecutive oncological PET-CT scans. In this scenario, the design and implementation of a supervised machine learning system to predict and quantify cancer progression or response conditions by introducing a novel feature set that models the underlying clinical context is described. Performance results in 100 clinical cases (corresponding to 200 whole body PET-CT scans) in comparing expert-based visual analysis and classifier decision making show up to 70% accuracy within a completely automatic pipeline and 90% accuracy when providing the system with expert-guided PET tumor segmentation masks.
Keywords: Computer aided diagnosis; Nuclear medicine; Machine learning; Image processing; Quantitative analysis
|
|
|
Frederic Sampedro, & Sergio Escalera. (2015). Spatial codification of label predictions in Multi-scale Stacked Sequential Learning: A case study on multi-class medical volume segmentation. IETCV - IET Computer Vision, 9(3), 439–446.
Abstract: In this study, the authors propose the spatial codification of label predictions within the multi-scale stacked sequential learning (MSSL) framework, a successful learning scheme to deal with non-independent identically distributed data entries. After providing a motivation for this objective, they describe its theoretical framework based on the introduction of the blurred shape model as a smart descriptor to codify the spatial distribution of the predicted labels and define the new extended feature set for the second stacked classifier. They then particularise this scheme to be applied in volume segmentation applications. Finally, they test the implementation of the proposed framework in two medical volume segmentation datasets, obtaining significant performance improvements (with a 95% of confidence) in comparison to standard Adaboost classifier and classical MSSL approaches.
|
|
|
Frederic Sampedro, Anna Domenech, Sergio Escalera, & Ignasi Carrio. (2015). Deriving global quantitative tumor response parameters from 18F-FDG PET-CT scans in patients with non-Hodgkins lymphoma. NMC - Nuclear Medicine Communications, 36(4), 328–333.
Abstract: OBJECTIVES:
The aim of the study was to address the need for quantifying the global cancer time evolution magnitude from a pair of time-consecutive positron emission tomography-computed tomography (PET-CT) scans. In particular, we focus on the computation of indicators using image-processing techniques that seek to model non-Hodgkin's lymphoma (NHL) progression or response severity.
MATERIALS AND METHODS:
A total of 89 pairs of time-consecutive PET-CT scans from NHL patients were stored in a nuclear medicine station for subsequent analysis. These were classified by a consensus of nuclear medicine physicians into progressions, partial responses, mixed responses, complete responses, and relapses. The cases of each group were ordered by magnitude following visual analysis. Thereafter, a set of quantitative indicators designed to model the cancer evolution magnitude within each group were computed using semiautomatic and automatic image-processing techniques. Performance evaluation of the proposed indicators was measured by a correlation analysis with the expert-based visual analysis.
RESULTS:
The set of proposed indicators achieved Pearson's correlation results in each group with respect to the expert-based visual analysis: 80.2% in progressions, 77.1% in partial response, 68.3% in mixed response, 88.5% in complete response, and 100% in relapse. In the progression and mixed response groups, the proposed indicators outperformed the common indicators used in clinical practice [changes in metabolic tumor volume, mean, maximum, peak standardized uptake value (SUV mean, SUV max, SUV peak), and total lesion glycolysis] by more than 40%.
CONCLUSION:
Computing global indicators of NHL response using PET-CT imaging techniques offers a strong correlation with the associated expert-based visual analysis, motivating the future incorporation of such quantitative and highly observer-independent indicators in oncological decision making or treatment response evaluation scenarios.
|
|
|
Frederic Sampedro, Anna Domenech, Sergio Escalera, & Ignasi Carrio. (2017). Computing quantitative indicators of structural renal damage in pediatric DMSA scans. REMNIM - Revista Española de Medicina Nuclear e Imagen Molecular, 36(2), 72–77.
Abstract: OBJECTIVES:
The proposal and implementation of a computational framework for the quantification of structural renal damage from 99mTc-dimercaptosuccinic acid (DMSA) scans. The aim of this work is to propose, implement, and validate a computational framework for the quantification of structural renal damage from DMSA scans and in an observer-independent manner.
MATERIALS AND METHODS:
From a set of 16 pediatric DMSA-positive scans and 16 matched controls and using both expert-guided and automatic approaches, a set of image-derived quantitative indicators was computed based on the relative size, intensity and histogram distribution of the lesion. A correlation analysis was conducted in order to investigate the association of these indicators with other clinical data of interest in this scenario, including C-reactive protein (CRP), white cell count, vesicoureteral reflux, fever, relative perfusion, and the presence of renal sequelae in a 6-month follow-up DMSA scan.
RESULTS:
A fully automatic lesion detection and segmentation system was able to successfully classify DMSA-positive from negative scans (AUC=0.92, sensitivity=81% and specificity=94%). The image-computed relative size of the lesion correlated with the presence of fever and CRP levels (p<0.05), and a measurement derived from the distribution histogram of the lesion obtained significant performance results in the detection of permanent renal damage (AUC=0.86, sensitivity=100% and specificity=75%).
CONCLUSIONS:
The proposal and implementation of a computational framework for the quantification of structural renal damage from DMSA scans showed a promising potential to complement visual diagnosis and non-imaging indicators.
|
|
|
Frederic Sampedro, Anna Domenech, & Sergio Escalera. (2014). Obtaining quantitative global tumoral state indicators based on whole-body PET/CT scans: A breast cancer case study. NMC - Nuclear Medicine Communications, 35(4), 362–371.
Abstract: Objectives: In this work we address the need for the computation of quantitative global tumoral state indicators from oncological whole-body PET/computed tomography scans. The combination of such indicators with other oncological information such as tumor markers or biopsy results would prove useful in oncological decision-making scenarios.
Materials and methods: From an ordering of 100 breast cancer patients on the basis of oncological state through visual analysis by a consensus of nuclear medicine specialists, a set of numerical indicators computed from image analysis of the PET/computed tomography scan is presented, which attempts to summarize a patient’s oncological state in a quantitative manner taking into consideration the total tumor volume, aggressiveness, and spread.
Results: Results obtained by comparative analysis of the proposed indicators with respect to the experts’ evaluation show up to 87% Pearson’s correlation coefficient when providing expert-guided PET metabolic tumor volume segmentation and 64% correlation when using completely automatic image analysis techniques.
Conclusion: Global quantitative tumor information obtained by whole-body PET/CT image analysis can prove useful in clinical nuclear medicine settings and oncological decision-making scenarios. The completely automatic computation of such indicators would improve its impact as time efficiency and specialist independence would be achieved.
|
|
|
Frederic Sampedro, Anna Domenech, & Sergio Escalera. (2014). Static and dynamic computational cancer spread quantification in whole body FDG-PET/CT scans. JMIHI - Journal of Medical Imaging and Health Informatics, 4(6), 825–831.
Abstract: In this work we address the computational cancer spread quantification scenario in whole body FDG-PET/CT scans. At the static level, this setting can be modeled as a clustering problem on the set of 3D connected components of the whole body PET tumoral segmentation mask carried out by nuclear medicine physicians. At the dynamic level, and ad-hoc algorithm is proposed in order to quantify the cancer spread time evolution which, when combined with other existing indicators, gives rise to the metabolic tumor volume-aggressiveness-spread time evolution chart, a novel tool that we claim that would prove useful in nuclear medicine and oncological clinical or research scenarios. Good performance results of the proposed methodologies both at the clinical and technological level are shown using a dataset of 48 segmented whole body FDG-PET/CT scans.
Keywords: CANCER SPREAD; COMPUTER AIDED DIAGNOSIS; MEDICAL IMAGING; TUMOR QUANTIFICATION
|
|
|
Franck Davoine, & Fadi Dornaika. (2005). Head and facial animation tracking using appearance-adaptive models and particle filters. In V. Pavlovic and T.S. Huang (editors), Real–Time Vision for Human–Computer Interaction.
|
|
|
Francisco Jose Perales, Yuhua Luo, & Juan J. Villanueva. (1991). Un metodo Automatico de Rotoscopia Sin Marcas para el Estudio del Movimiento Humano Basado en un modelo Biomecanico. In Primer Congreso Español de Informatica Grafica (pp. 53–65).
|
|
|
Francisco Jose Perales, Juan J. Villanueva, & Yuhua Luo. (1991). Matching Criteria. In Computer and Information Sciences VI, Proceedings of the 1991 International Symposium on Computer and Information Sciences (Vol. 1, pp. 1029–1038). Elsevier Science Pub.
|
|
|
Francisco Jose Perales, Juan J. Villanueva, & Yuhua Luo. (1991). An automatic two-camera human motion perception system based on biomechanical model matching. In IEEE International Conference on Systems, Man and Cybernetics (Vol. 2, pp. 856–858).
|
|
|
Francisco Javier Orozco, Xavier Roca, & Jordi Gonzalez. (2008). Real-Time Gaze Tracking with Appearance-Based Models. MVAP - Machine Vision Applications, 20(6), 353–364.
Abstract: Psychological evidence has emphasized the importance of eye gaze analysis in human computer interaction and emotion interpretation. To this end, current image analysis algorithms take into consideration eye-lid and iris motion detection using colour information and edge detectors. However, eye movement is fast and and hence difficult to use to obtain a precise and robust tracking. Instead, our
method proposed to describe eyelid and iris movements as continuous variables using appearance-based tracking. This approach combines the strengths of adaptive appearance models, optimization methods and backtracking techniques.Thus,
in the proposed method textures are learned on-line from near frontal images and illumination changes, occlusions and fast movements are managed. The method achieves real-time performance by combining two appearance-based trackers to a
backtracking algorithm for eyelid estimation and another for iris estimation. These contributions represent a significant advance towards a reliable gaze motion description for HCI and expression analysis, where the strength of complementary
methodologies are combined to avoid using high quality images, colour information, texture training, camera settings and other time-consuming processes.
Keywords: Keywords Eyelid and iris tracking, Appearance models, Blinking, Iris saccade, Real-time gaze tracking
|
|
|
Francisco Javier Orozco, Pau Baiget, Jordi Gonzalez, & Xavier Roca. (2006). Eyelids and Face Tracking in Real-Time.
|
|
|
Francisco Javier Orozco, Ognjen Rudovic, Jordi Gonzalez, & Maja Pantic. (2013). Hierarchical On-line Appearance-Based Tracking for 3D Head Pose, Eyebrows, Lips, Eyelids and Irises. IMAVIS - Image and Vision Computing, 31(4), 322–340.
Abstract: In this paper, we propose an On-line Appearance-Based Tracker (OABT) for simultaneous tracking of 3D head pose, lips, eyebrows, eyelids and irises in monocular video sequences. In contrast to previously proposed tracking approaches, which deal with face and gaze tracking separately, our OABT can also be used for eyelid and iris tracking, as well as 3D head pose, lips and eyebrows facial actions tracking. Furthermore, our approach applies an on-line learning of changes in the appearance of the tracked target. Hence, the prior training of appearance models, which usually requires a large amount of labeled facial images, is avoided. Moreover, the proposed method is built upon a hierarchical combination of three OABTs, which are optimized using a Levenberg–Marquardt Algorithm (LMA) enhanced with line-search procedures. This, in turn, makes the proposed method robust to changes in lighting conditions, occlusions and translucent textures, as evidenced by our experiments. Finally, the proposed method achieves head and facial actions tracking in real-time.
Keywords: On-line appearance models; Levenberg–Marquardt algorithm; Line-search optimization; 3D face tracking; Facial action tracking; Eyelid tracking; Iris tracking
|
|