toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author Rozenn Dhayot; Fernando Vilariño; Gerard Lacey edit  doi
openurl 
  Title Improving the Quality of Color Colonoscopy Videos Type Journal Article
  Year 2008 Publication EURASIP Journal on Image and Video Processing Abbreviated Journal EURASIP JIVP  
  Volume 139429 Issue 1 Pages 1-9  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area 800 Expedition Conference  
  Notes (down) MV;SIAI Approved no  
  Call Number fernando @ fernando @ Serial 2422  
Permanent link to this record
 

 
Author Patrick Brandao; O. Zisimopoulos; E. Mazomenos; G. Ciutib; Jorge Bernal; M. Visentini-Scarzanell; A. Menciassi; P. Dario; A. Koulaouzidis; A. Arezzo; D.J. Hawkes; D. Stoyanov edit   pdf
url  doi
openurl 
  Title Towards a computed-aided diagnosis system in colonoscopy: Automatic polyp segmentation using convolution neural networks Type Journal
  Year 2018 Publication Journal of Medical Robotics Research Abbreviated Journal JMRR  
  Volume 3 Issue 2 Pages  
  Keywords convolutional neural networks; colonoscopy; computer aided diagnosis  
  Abstract Early diagnosis is essential for the successful treatment of bowel cancers including colorectal cancer (CRC) and capsule endoscopic imaging with robotic actuation can be a valuable diagnostic tool when combined with automated image analysis. We present a deep learning rooted detection and segmentation framework for recognizing lesions in colonoscopy and capsule endoscopy images. We restructure established convolution architectures, such as VGG and ResNets, by converting them into fully-connected convolution networks (FCNs), ne-tune them and study their capabilities for polyp segmentation and detection. We additionally use Shape-from-Shading (SfS) to recover depth and provide a richer representation of the tissue's structure in colonoscopy images. Depth is
incorporated into our network models as an additional input channel to the RGB information and we demonstrate that the resulting network yields improved performance. Our networks are tested on publicly available datasets and the most accurate segmentation model achieved a mean segmentation IU of 47.78% and 56.95% on the ETIS-Larib and CVC-Colon datasets, respectively. For polyp
detection, the top performing models we propose surpass the current state of the art with detection recalls superior to 90% for all datasets tested. To our knowledge, we present the rst work to use FCNs for polyp segmentation in addition to proposing a novel combination of SfS and RGB that boosts performance.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) MV; no menciona Approved no  
  Call Number BZM2018 Serial 2976  
Permanent link to this record
 

 
Author Ana Garcia Rodriguez; Jorge Bernal; F. Javier Sanchez; Henry Cordova; Rodrigo Garces Duran; Cristina Rodriguez de Miguel; Gloria Fernandez Esparrach edit  url
doi  openurl
  Title Polyp fingerprint: automatic recognition of colorectal polyps’ unique features Type Journal Article
  Year 2020 Publication Surgical Endoscopy and other Interventional Techniques Abbreviated Journal SEND  
  Volume 34 Issue 4 Pages 1887-1889  
  Keywords  
  Abstract BACKGROUND:
Content-based image retrieval (CBIR) is an application of machine learning used to retrieve images by similarity on the basis of features. Our objective was to develop a CBIR system that could identify images containing the same polyp ('polyp fingerprint').

METHODS:
A machine learning technique called Bag of Words was used to describe each endoscopic image containing a polyp in a unique way. The system was tested with 243 white light images belonging to 99 different polyps (for each polyp there were at least two images representing it in two different temporal moments). Images were acquired in routine colonoscopies at Hospital Clínic using high-definition Olympus endoscopes. The method provided for each image the closest match within the dataset.

RESULTS:
The system matched another image of the same polyp in 221/243 cases (91%). No differences were observed in the number of correct matches according to Paris classification (protruded: 90.7% vs. non-protruded: 91.3%) and size (< 10 mm: 91.6% vs. > 10 mm: 90%).

CONCLUSIONS:
A CBIR system can match accurately two images containing the same polyp, which could be a helpful aid for polyp image recognition.

KEYWORDS:
Artificial intelligence; Colorectal polyps; Content-based image retrieval
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) MV; no menciona Approved no  
  Call Number Admin @ si @ Serial 3403  
Permanent link to this record
 

 
Author Jorge Bernal; F. Javier Sanchez; Gloria Fernandez Esparrach; Debora Gil; Cristina Rodriguez de Miguel; Fernando Vilariño edit   pdf
doi  openurl
  Title WM-DOVA Maps for Accurate Polyp Highlighting in Colonoscopy: Validation vs. Saliency Maps from Physicians Type Journal Article
  Year 2015 Publication Computerized Medical Imaging and Graphics Abbreviated Journal CMIG  
  Volume 43 Issue Pages 99-111  
  Keywords Polyp localization; Energy Maps; Colonoscopy; Saliency; Valley detection  
  Abstract We introduce in this paper a novel polyp localization method for colonoscopy videos. Our method is based on a model of appearance for polyps which defines polyp boundaries in terms of valley information. We propose the integration of valley information in a robust way fostering complete, concave and continuous boundaries typically associated to polyps. This integration is done by using a window of radial sectors which accumulate valley information to create WMDOVA1 energy maps related with the likelihood of polyp presence. We perform a double validation of our maps, which include the introduction of two new databases, including the first, up to our knowledge, fully annotated database with clinical metadata associated. First we assess that the highest value corresponds with the location of the polyp in the image. Second, we show that WM-DOVA energy maps can be comparable with saliency maps obtained from physicians' fixations obtained via an eye-tracker. Finally, we prove that our method outperforms state-of-the-art computational saliency results. Our method shows good performance, particularly for small polyps which are reported to be the main sources of polyp miss-rate, which indicates the potential applicability of our method in clinical practice.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0895-6111 ISBN Medium  
  Area Expedition Conference  
  Notes (down) MV; IAM; 600.047; 600.060; 600.075;SIAI Approved no  
  Call Number Admin @ si @ BSF2015 Serial 2609  
Permanent link to this record
 

 
Author Onur Ferhat; Fernando Vilariño edit   pdf
doi  openurl
  Title Low Cost Eye Tracking: The Current Panorama Type Journal Article
  Year 2016 Publication Computational Intelligence and Neuroscience Abbreviated Journal CIN  
  Volume Issue Pages Article ID 8680541  
  Keywords  
  Abstract Despite the availability of accurate, commercial gaze tracker devices working with infrared (IR) technology, visible light gaze tracking constitutes an interesting alternative by allowing scalability and removing hardware requirements. Over the last years, this field has seen examples of research showing performance comparable to the IR alternatives. In this work, we survey the previous work on remote, visible light gaze trackers and analyze the explored techniques from various perspectives such as calibration strategies, head pose invariance, and gaze estimation techniques. We also provide information on related aspects of research such as public datasets to test against, open source projects to build upon, and gaze tracking services to directly use in applications. With all this information, we aim to provide the contemporary and future researchers with a map detailing previously explored ideas and the required tools.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) MV; 605.103; 600.047; 600.097;SIAI Approved no  
  Call Number Admin @ si @ FeV2016 Serial 2744  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: