toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author Laura Igual; Agata Lapedriza; Ricard Borras edit   pdf
doi  openurl
  Title Robust Gait-Based Gender Classification using Depth Cameras Type Journal Article
  Year 2013 Publication EURASIP Journal on Advances in Signal Processing Abbreviated Journal EURASIPJ  
  Volume 37 Issue (up) 1 Pages 72-80  
  Keywords  
  Abstract This article presents a new approach for gait-based gender recognition using depth cameras, that can run in real time. The main contribution of this study is a new fast feature extraction strategy that uses the 3D point cloud obtained from the frames in a gait cycle. For each frame, these points are aligned according to their centroid and grouped. After that, they are projected into their PCA plane, obtaining a representation of the cycle particularly robust against view changes. Then, final discriminative features are computed by first making a histogram of the projected points and then using linear discriminant analysis. To test the method we have used the DGait database, which is currently the only publicly available database for gait analysis that includes depth information. We have performed experiments on manually labeled cycles and over whole video sequences, and the results show that our method improves the accuracy significantly, compared with state-of-the-art systems which do not use depth information. Furthermore, our approach is insensitive to illumination changes, given that it discards the RGB information. That makes the method especially suitable for real applications, as illustrated in the last part of the experiments section.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MILAB; OR;MV Approved no  
  Call Number Admin @ si @ ILB2013 Serial 2144  
Permanent link to this record
 

 
Author Michal Drozdzal; Santiago Segui; Carolina Malagelada; Fernando Azpiroz; Petia Radeva edit   pdf
doi  openurl
  Title Adaptable image cuts for motility inspection using WCE Type Journal Article
  Year 2013 Publication Computerized Medical Imaging and Graphics Abbreviated Journal CMIG  
  Volume 37 Issue (up) 1 Pages 72-80  
  Keywords  
  Abstract The Wireless Capsule Endoscopy (WCE) technology allows the visualization of the whole small intestine tract. Since the capsule is freely moving, mainly by the means of peristalsis, the data acquired during the study gives a lot of information about the intestinal motility. However, due to: (1) huge amount of frames, (2) complex intestinal scene appearance and (3) intestinal dynamics that make difficult the visualization of the small intestine physiological phenomena, the analysis of the WCE data requires computer-aided systems to speed up the analysis. In this paper, we propose an efficient algorithm for building a novel representation of the WCE video data, optimal for motility analysis and inspection. The algorithm transforms the 3D video data into 2D longitudinal view by choosing the most informative, from the intestinal motility point of view, part of each frame. This step maximizes the lumen visibility in its longitudinal extension. The task of finding “the best longitudinal view” has been defined as a cost function optimization problem which global minimum is obtained by using Dynamic Programming. Validation on both synthetic data and WCE data shows that the adaptive longitudinal view is a good alternative to the traditional motility analysis done by video analysis. The proposed novel data representation a new, holistic insight into the small intestine motility, allowing to easily define and analyze motility events that are difficult to spot by analyzing WCE video. Moreover, the visual inspection of small intestine motility is 4 times faster then by means of video skimming of the WCE.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MILAB; OR; 600.046; 605.203 Approved no  
  Call Number Admin @ si @ DSM2012 Serial 2151  
Permanent link to this record
 

 
Author Fadi Dornaika; Abdelmalik Moujahid; Bogdan Raducanu edit   pdf
url  doi
openurl 
  Title Facial expression recognition using tracked facial actions: Classifier performance analysis Type Journal Article
  Year 2013 Publication Engineering Applications of Artificial Intelligence Abbreviated Journal EAAI  
  Volume 26 Issue (up) 1 Pages 467-477  
  Keywords Visual face tracking; 3D deformable models; Facial actions; Dynamic facial expression recognition; Human–computer interaction  
  Abstract In this paper, we address the analysis and recognition of facial expressions in continuous videos. More precisely, we study classifiers performance that exploit head pose independent temporal facial action parameters. These are provided by an appearance-based 3D face tracker that simultaneously provides the 3D head pose and facial actions. The use of such tracker makes the recognition pose- and texture-independent. Two different schemes are studied. The first scheme adopts a dynamic time warping technique for recognizing expressions where training data are given by temporal signatures associated with different universal facial expressions. The second scheme models temporal signatures associated with facial actions with fixed length feature vectors (observations), and uses some machine learning algorithms in order to recognize the displayed expression. Experiments quantified the performance of different schemes. These were carried out on CMU video sequences and home-made video sequences. The results show that the use of dimension reduction techniques on the extracted time series can improve the classification performance. Moreover, these experiments show that the best recognition rate can be above 90%.  
  Address  
  Corporate Author Thesis  
  Publisher Elsevier Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes OR; 600.046;MV Approved no  
  Call Number Admin @ si @ DMR2013 Serial 2185  
Permanent link to this record
 

 
Author Cesar Isaza; Joaquin Salas; Bogdan Raducanu edit  doi
openurl 
  Title Evaluation of Intrinsic Image Algorithms to Detect the Shadows Cast by Static Objects Outdoors Type Journal Article
  Year 2012 Publication Sensors Abbreviated Journal SENS  
  Volume 12 Issue (up) 10 Pages 13333-13348  
  Keywords  
  Abstract In some automatic scene analysis applications, the presence of shadows becomes a nuisance that is necessary to deal with. As a consequence, a preliminary stage in many computer vision algorithms is to attenuate their effect. In this paper, we focus our attention on the detection of shadows cast by static objects outdoors, as the scene is viewed for extended periods of time (days, weeks) from a fixed camera and considering daylight intervals where the main source of light is the sun. In this context, we report two contributions. First, we introduce the use of synthetic images for which ground truth can be generated automatically, avoiding the tedious effort of manual annotation. Secondly, we report a novel application of the intrinsic image concept to the automatic detection of shadows cast by static objects in outdoors. We make both a quantitative and a qualitative evaluation of several algorithms based on this image representation. For the quantitative evaluation, we used the synthetic data set, while for the qualitative evaluation we used both data sets. Our experimental results show that the evaluated methods can partially solve the problem of shadow detection.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes OR;MV Approved no  
  Call Number Admin @ si @ ISR2012b Serial 2173  
Permanent link to this record
 

 
Author Fosca De Iorio; Carolina Malagelada; Fernando Azpiroz; M. Maluenda; C. Violanti; Laura Igual; Jordi Vitria; Juan R. Malagelada edit  doi
openurl 
  Title Intestinal motor activity, endoluminal motion and transit Type Journal Article
  Year 2009 Publication Neurogastroenterology & Motility Abbreviated Journal NEUMOT  
  Volume 21 Issue (up) 12 Pages 1264–e119  
  Keywords  
  Abstract A programme for evaluation of intestinal motility has been recently developed based on endoluminal image analysis using computer vision methodology and machine learning techniques. Our aim was to determine the effect of intestinal muscle inhibition on wall motion, dynamics of luminal content and transit in the small bowel. Fourteen healthy subjects ingested the endoscopic capsule (Pillcam, Given Imaging) in fasting conditions. Seven of them received glucagon (4.8 microg kg(-1) bolus followed by a 9.6 microg kg(-1) h(-1) infusion during 1 h) and in the other seven, fasting activity was recorded, as controls. This dose of glucagon has previously shown to inhibit both tonic and phasic intestinal motor activity. Endoluminal image and displacement was analyzed by means of a computer vision programme specifically developed for the evaluation of muscular activity (contractile and non-contractile patterns), intestinal contents, endoluminal motion and transit. Thirty-minute periods before, during and after glucagon infusion were analyzed and compared with equivalent periods in controls. No differences were found in the parameters measured during the baseline (pretest) periods when comparing glucagon and control experiments. During glucagon infusion, there was a significant reduction in contractile activity (0.2 +/- 0.1 vs 4.2 +/- 0.9 luminal closures per min, P < 0.05; 0.4 +/- 0.1 vs 3.4 +/- 1.2% of images with radial wrinkles, P < 0.05) and a significant reduction of endoluminal motion (82 +/- 9 vs 21 +/- 10% of static images, P < 0.05). Endoluminal image analysis, by means of computer vision and machine learning techniques, can reliably detect reduced intestinal muscle activity and motion.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes OR;MILAB;MV Approved no  
  Call Number BCNPCL @ bcnpcl @ DMA2009 Serial 1251  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: