|
Albert Clapes, Miguel Reyes, & Sergio Escalera. (2013). Multi-modal User Identification and Object Recognition Surveillance System. PRL - Pattern Recognition Letters, 34(7), 799–808.
Abstract: We propose an automatic surveillance system for user identification and object recognition based on multi-modal RGB-Depth data analysis. We model a RGBD environment learning a pixel-based background Gaussian distribution. Then, user and object candidate regions are detected and recognized using robust statistical approaches. The system robustly recognizes users and updates the system in an online way, identifying and detecting new actors in the scene. Moreover, segmented objects are described, matched, recognized, and updated online using view-point 3D descriptions, being robust to partial occlusions and local 3D viewpoint rotations. Finally, the system saves the historic of user–object assignments, being specially useful for surveillance scenarios. The system has been evaluated on a novel data set containing different indoor/outdoor scenarios, objects, and users, showing accurate recognition and better performance than standard state-of-the-art approaches.
Keywords: Multi-modal RGB-Depth data analysis; User identification; Object recognition; Intelligent surveillance; Visual features; Statistical learning
|
|
|
Marina Alberti, Simone Balocco, Xavier Carrillo, J. Mauri, & Petia Radeva. (2013). Automatic non-rigid temporal alignment of IVUS sequences: method and quantitative validation. UMB - Ultrasound in Medicine and Biology, 39(9), 1698–712.
Abstract: Clinical studies on atherosclerosis regression/progression performed by intravascular ultrasound analysis would benefit from accurate alignment of sequences of the same patient before and after clinical interventions and at follow-up. In this article, a methodology for automatic alignment of intravascular ultrasound sequences based on the dynamic time warping technique is proposed. The non-rigid alignment is adapted to the specific task by applying it to multidimensional signals describing the morphologic content of the vessel. Moreover, dynamic time warping is embedded into a framework comprising a strategy to address partial overlapping between acquisitions and a term that regularizes non-physiologic temporal compression/expansion of the sequences. Extensive validation is performed on both synthetic and in vivo data. The proposed method reaches alignment errors of approximately 0.43 mm for pairs of sequences acquired during the same intervention phase and 0.77 mm for pairs of sequences acquired at successive intervention stages.
Keywords: Intravascular ultrasound; Dynamic time warping; Non-rigid alignment; Sequence matching; Partial overlapping strategy
|
|
|
Simone Balocco, Carlo Gatta, Francesco Ciompi, A. Wahle, Petia Radeva, S. Carlier, et al. (2014). Standardized evaluation methodology and reference database for evaluating IVUS image segmentation. CMIG - Computerized Medical Imaging and Graphics, 38(2), 70–90.
Abstract: This paper describes an evaluation framework that allows a standardized and quantitative comparison of IVUS lumen and media segmentation algorithms. This framework has been introduced at the MICCAI 2011 Computing and Visualization for (Intra)Vascular Imaging (CVII) workshop, comparing the results of eight teams that participated.
We describe the available data-base comprising of multi-center, multi-vendor and multi-frequency IVUS datasets, their acquisition, the creation of the reference standard and the evaluation measures. The approaches address segmentation of the lumen, the media, or both borders; semi- or fully-automatic operation; and 2-D vs. 3-D methodology. Three performance measures for quantitative analysis have
been proposed. The results of the evaluation indicate that segmentation of the vessel lumen and media is possible with an accuracy that is comparable to manual annotation when semi-automatic methods are used, as well as encouraging results can be obtained also in case of fully-automatic segmentation. The analysis performed in this paper also highlights the challenges in IVUS segmentation that remains to be
solved.
Keywords: IVUS (intravascular ultrasound); Evaluation framework; Algorithm comparison; Image segmentation
|
|
|
Laura Igual, Joan Carles Soliva, Sergio Escalera, Roger Gimeno, Oscar Vilarroya, & Petia Radeva. (2012). Automatic Brain Caudate Nuclei Segmentation and Classification in Diagnostic of Attention-Deficit/Hyperactivity Disorder. CMIG - Computerized Medical Imaging and Graphics, 36(8), 591–600.
Abstract: We present a fully automatic diagnostic imaging test for Attention-Deficit/Hyperactivity Disorder diagnosis assistance based on previously found evidences of caudate nucleus volumetric abnormalities. The proposed method consists of different steps: a new automatic method for external and internal segmentation of caudate based on Machine Learning methodologies; the definition of a set of new volume relation features, 3D Dissociated Dipoles, used for caudate representation and classification. We separately validate the contributions using real data from a pediatric population and show precise internal caudate segmentation and discrimination power of the diagnostic test, showing significant performance improvements in comparison to other state-of-the-art methods.
Keywords: Automatic caudate segmentation; Attention-Deficit/Hyperactivity Disorder; Diagnostic test; Machine learning; Decision stumps; Dissociated dipoles
|
|
|
Laura Igual, Agata Lapedriza, & Ricard Borras. (2013). Robust Gait-Based Gender Classification using Depth Cameras. EURASIPJ - EURASIP Journal on Advances in Signal Processing, 37(1), 72–80.
Abstract: This article presents a new approach for gait-based gender recognition using depth cameras, that can run in real time. The main contribution of this study is a new fast feature extraction strategy that uses the 3D point cloud obtained from the frames in a gait cycle. For each frame, these points are aligned according to their centroid and grouped. After that, they are projected into their PCA plane, obtaining a representation of the cycle particularly robust against view changes. Then, final discriminative features are computed by first making a histogram of the projected points and then using linear discriminant analysis. To test the method we have used the DGait database, which is currently the only publicly available database for gait analysis that includes depth information. We have performed experiments on manually labeled cycles and over whole video sequences, and the results show that our method improves the accuracy significantly, compared with state-of-the-art systems which do not use depth information. Furthermore, our approach is insensitive to illumination changes, given that it discards the RGB information. That makes the method especially suitable for real applications, as illustrated in the last part of the experiments section.
|
|