|
Records |
Links |
|
Author |
Oriol Rodriguez-Leor; J. Mauri; Eduard Fernandez-Nofrerias; Antonio Tovar; Vicente del Valle; Aura Hernandez-Sabate; Debora Gil; Petia Radeva |
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Utilización de la Estructura de los Campos Vectoriales para la Detección de la Adventicia en Imágenes de Ecografía Intracoronaria |
Type |
Journal Article |
|
Year |
2004 |
Publication |
Revista Internacional de Enfermedades Cardiovasculares Revista Española de Cardiología |
Abbreviated Journal |
|
|
|
Volume |
57 |
Issue |
2 |
Pages |
100 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN ![sorted by ISSN field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
SEC |
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RMF2004 |
Serial |
1642 |
|
Permanent link to this record |
|
|
|
|
Author |
Misael Rosales; Petia Radeva; Oriol Rodriguez-Leor; Debora Gil |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Modelling of image-catheter motion for 3-D IVUS |
Type |
Journal Article |
|
Year |
2009 |
Publication |
Medical image analysis |
Abbreviated Journal |
MIA |
|
|
Volume |
13 |
Issue |
1 |
Pages |
91-104 |
|
|
Keywords |
Intravascular ultrasound (IVUS); Motion estimation; Motion decomposition; Fourier |
|
|
Abstract |
Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Usually, to overcome the image motion artifact ECG-gating and image-gated approaches are proposed, leading to slowing the pullback acquisition or disregarding part of IVUS data. In this paper, we argue that the image motion is due to 3-D vessel geometry as well as cardiac dynamics, and propose a dynamic model based on the tracking of an elliptical vessel approximation to recover the rigid transformation and align IVUS images without loosing any IVUS data. We report an extensive validation with synthetic simulated data and in vivo IVUS sequences of 30 patients achieving an average reduction of the image artifact of 97% in synthetic data and 79% in real-data. Our study shows that IVUS alignment improves longitudinal analysis of the IVUS data and is a necessary step towards accurate reconstruction and volumetric measurements of 3-D IVUS. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN ![sorted by ISSN field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RRR2009 |
Serial |
1646 |
|
Permanent link to this record |
|
|
|
|
Author |
David Rotger; Misael Rosales; Jaume Garcia; Oriol Pujol ; J. Mauri; Petia Radeva |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
|
|
Title |
Active Vessel: A New Multimedia Workstation for Intravascular Ultrasound and Angiography Fusion |
Type |
Journal Article |
|
Year |
2003 |
Publication |
Computers in Cardiology |
Abbreviated Journal |
|
|
|
Volume |
30 |
Issue |
|
Pages |
65-68 |
|
|
Keywords |
|
|
|
Abstract |
AcriveVessel is a new multimedia workstation which enables the visualization, acquisition and handling of both image modalities, on- and ofline. It enables DICOM v3.0 decompression and browsing, video acquisition,repmduction and storage for IntraVascular UltraSound (IVUS) and angiograms with their corresponding ECG,automatic catheter segmentation in angiography images (using fast marching algorithm). BSpline models definition for vessel layers on IVUS images sequence and an extensively validated tool to fuse information. This approach defines the correspondence of every IVUS image with its correspondent point in the angiogram and viceversa. The 3 0 reconstruction of the NUS catheterhessel enables real distance measurements as well as threedimensional visualization showing vessel tortuosity in the space. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN ![sorted by ISSN field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB;HuPBA |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RRG2003 |
Serial |
1647 |
|
Permanent link to this record |
|
|
|
|
Author |
Jose Seabra; Francesco Ciompi; Oriol Pujol; J. Mauri; Petia Radeva; Joao Sanchez |
![goto web page (via DOI) doi](http://refbase.cvc.uab.es/img/doi.gif)
|
|
Title |
Rayleigh Mixture Model for Plaque Characterization in Intravascular Ultrasound |
Type |
Journal Article |
|
Year |
2011 |
Publication |
IEEE Transactions on Biomedical Engineering |
Abbreviated Journal |
TBME |
|
|
Volume |
58 |
Issue |
5 |
Pages |
1314-1324 |
|
|
Keywords |
|
|
|
Abstract |
Vulnerable plaques are the major cause of carotid and coronary vascular problems, such as heart attack or stroke. A correct modeling of plaque echomorphology and composition can help the identification of such lesions. The Rayleigh distribution is widely used to describe (nearly) homogeneous areas in ultrasound images. Since plaques may contain tissues with heterogeneous regions, more complex distributions depending on multiple parameters are usually needed, such as Rice, K or Nakagami distributions. In such cases, the problem formulation becomes more complex, and the optimization procedure to estimate the plaque echomorphology is more difficult. Here, we propose to model the tissue echomorphology by means of a mixture of Rayleigh distributions, known as the Rayleigh mixture model (RMM). The problem formulation is still simple, but its ability to describe complex textural patterns is very powerful. In this paper, we present a method for the automatic estimation of the RMM mixture parameters by means of the expectation maximization algorithm, which aims at characterizing tissue echomorphology in ultrasound (US). The performance of the proposed model is evaluated with a database of in vitro intravascular US cases. We show that the mixture coefficients and Rayleigh parameters explicitly derived from the mixture model are able to accurately describe different plaque types and to significantly improve the characterization performance of an already existing methodology. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN ![sorted by ISSN field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB;HuPBA |
Approved |
no |
|
|
Call Number |
Admin @ si @ SCP2011 |
Serial |
1712 |
|
Permanent link to this record |
|
|
|
|
Author |
Xavier Carrillo; E Fernandez-Nofrerias; Francesco Ciompi; Oriol Rodriguez-Leor; Petia Radeva; Neus Salvatella; Oriol Pujol; J. Mauri; A. Bayes |
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Changes in Radial Artery Volume Assessed Using Intravascular Ultrasound: A Comparison of Two Vasodilator Regimens in Transradial Coronary Intervention |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Journal of Invasive Cardiology |
Abbreviated Journal |
JOIC |
|
|
Volume |
23 |
Issue |
10 |
Pages |
401-404 |
|
|
Keywords |
radial; vasodilator treatment; percutaneous coronary intervention; IVUS; volumetric IVUS analysis |
|
|
Abstract |
OBJECTIVES:
This study used intravascular ultrasound (IVUS) to evaluate radial artery volume changes after intraarterial administration of nitroglycerin and/or verapamil.
BACKGROUND:
Radial artery spasm, which is associated with radial artery size, is the main limitation of the transradial approach in percutaneous coronary interventions (PCI).
METHODS:
This prospective, randomized study compared the effect of two intra-arterial vasodilator regimens on radial artery volume: 0.2 mg of nitroglycerin plus 2.5 mg of verapamil (Group 1; n = 15) versus 2.5 mg of verapamil alone (Group 2; n = 15). Radial artery lumen volume was assessed using IVUS at two time points: at baseline (5 minutes after sheath insertion) and post-vasodilator (1 minute after drug administration). The luminal volume of the radial artery was computed using ECOC Random Fields (ECOC-RF), a technique used for automatic segmentation of luminal borders in longitudinal cut images from IVUS sequences.
RESULTS:
There was a significant increase in arterial lumen volume in both groups, with an increase from 451 ± 177 mm³ to 508 ± 192 mm³ (p = 0.001) in Group 1 and from 456 ± 188 mm³ to 509 ± 170 mm³ (p = 0.001) in Group 2. There were no significant differences between the groups in terms of absolute volume increase (58 mm³ versus 53 mm³, respectively; p = 0.65) or in relative volume increase (14% versus 20%, respectively; p = 0.69).
CONCLUSIONS:
Administration of nitroglycerin plus verapamil or verapamil alone to the radial artery resulted in similar increases in arterial lumen volume according to ECOC-RF IVUS measurements. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN ![sorted by ISSN field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB;HuPBA |
Approved |
no |
|
|
Call Number |
Admin @ si @ CFC2011 |
Serial |
1797 |
|
Permanent link to this record |