toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author Onur Ferhat; Fernando Vilariño edit   pdf
doi  openurl
  Title Low Cost Eye Tracking: The Current Panorama Type Journal Article
  Year 2016 Publication Computational Intelligence and Neuroscience Abbreviated Journal CIN  
  Volume Issue Pages Article ID 8680541  
  Keywords  
  Abstract Despite the availability of accurate, commercial gaze tracker devices working with infrared (IR) technology, visible light gaze tracking constitutes an interesting alternative by allowing scalability and removing hardware requirements. Over the last years, this field has seen examples of research showing performance comparable to the IR alternatives. In this work, we survey the previous work on remote, visible light gaze trackers and analyze the explored techniques from various perspectives such as calibration strategies, head pose invariance, and gaze estimation techniques. We also provide information on related aspects of research such as public datasets to test against, open source projects to build upon, and gaze tracking services to directly use in applications. With all this information, we aim to provide the contemporary and future researchers with a map detailing previously explored ideas and the required tools.  
  Address  
  Corporate Author (up) Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MV; 605.103; 600.047; 600.097;SIAI Approved no  
  Call Number Admin @ si @ FeV2016 Serial 2744  
Permanent link to this record
 

 
Author David Sanchez-Mendoza; David Masip; Agata Lapedriza edit   file
doi  openurl
  Title Emotion recognition from mid-level features Type Journal Article
  Year 2015 Publication Pattern Recognition Letters Abbreviated Journal PRL  
  Volume 67 Issue Part 1 Pages 66–74  
  Keywords Facial expression; Emotion recognition; Action units; Computer vision  
  Abstract In this paper we present a study on the use of Action Units as mid-level features for automatically recognizing basic and subtle emotions. We propose a representation model based on mid-level facial muscular movement features. We encode these movements dynamically using the Facial Action Coding System, and propose to use these intermediate features based on Action Units (AUs) to classify emotions. AUs activations are detected fusing a set of spatiotemporal geometric and appearance features. The algorithm is validated in two applications: (i) the recognition of 7 basic emotions using the publicly available Cohn-Kanade database, and (ii) the inference of subtle emotional cues in the Newscast database. In this second scenario, we consider emotions that are perceived cumulatively in longer periods of time. In particular, we Automatically classify whether video shoots from public News TV channels refer to Good or Bad news. To deal with the different video lengths we propose a Histogram of Action Units and compute it using a sliding window strategy on the frame sequences. Our approach achieves accuracies close to human perception.  
  Address  
  Corporate Author (up) Thesis  
  Publisher Elsevier B.V. Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0167-8655 ISBN Medium  
  Area Expedition Conference  
  Notes OR;MV Approved no  
  Call Number Admin @ si @ SML2015 Serial 2746  
Permanent link to this record
 

 
Author Gloria Fernandez Esparrach; Jorge Bernal; Maria Lopez Ceron; Henry Cordova; Cristina Sanchez Montes; Cristina Rodriguez de Miguel; F. Javier Sanchez edit   pdf
doi  openurl
  Title Exploring the clinical potential of an automatic colonic polyp detection method based on the creation of energy maps Type Journal Article
  Year 2016 Publication Endoscopy Abbreviated Journal END  
  Volume 48 Issue 9 Pages 837-842  
  Keywords  
  Abstract Background and aims: Polyp miss-rate is a drawback of colonoscopy that increases significantly in small polyps. We explored the efficacy of an automatic computer vision method for polyp detection.
Methods: Our method relies on a model that defines polyp boundaries as valleys of image intensity. Valley information is integrated into energy maps which represent the likelihood of polyp presence.
Results: In 24 videos containing polyps from routine colonoscopies, all polyps were detected in at least one frame. Mean values of the maximum of energy map were higher in frames with polyps than without (p<0.001). Performance improved in high quality frames (AUC= 0.79, 95%CI: 0.70-0.87 vs 0.75, 95%CI: 0.66-0.83). Using 3.75 as maximum threshold value, sensitivity and specificity for detection of polyps were 70.4% (95%CI: 60.3-80.8) and 72.4% (95%CI: 61.6-84.6), respectively.
Conclusion: Energy maps showed a good performance for colonic polyp detection. This indicates a potential applicability in clinical practice.
 
  Address  
  Corporate Author (up) Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MV; Approved no  
  Call Number Admin @ si @FBL2016 Serial 2778  
Permanent link to this record
 

 
Author Maria Elena Meza-de-Luna; Juan Ramon Terven Salinas; Bogdan Raducanu; Joaquin Salas edit   pdf
doi  openurl
  Title Assessing the Influence of Mirroring on the Perception of Professional Competence using Wearable Technology Type Journal Article
  Year 2016 Publication IEEE Transactions on Affective Computing Abbreviated Journal TAC  
  Volume 9 Issue 2 Pages 161-175  
  Keywords Mirroring; Nodding; Competence; Perception; Wearable Technology  
  Abstract Nonverbal communication is an intrinsic part in daily face-to-face meetings. A frequently observed behavior during social interactions is mirroring, in which one person tends to mimic the attitude of the counterpart. This paper shows that a computer vision system could be used to predict the perception of competence in dyadic interactions through the automatic detection of mirroring
events. To prove our hypothesis, we developed: (1) A social assistant for mirroring detection, using a wearable device which includes a video camera and (2) an automatic classifier for the perception of competence, using the number of nodding gestures and mirroring events as predictors. For our study, we used a mixed-method approach in an experimental design where 48 participants acting as customers interacted with a confederated psychologist. We found that the number of nods or mirroring events has a significant influence on the perception of competence. Our results suggest that: (1) Customer mirroring is a better predictor than psychologist mirroring; (2) the number of psychologist’s nods is a better predictor than the number of customer’s nods; (3) except for the psychologist mirroring, the computer vision algorithm we used worked about equally well whether it was acquiring images from wearable smartglasses or fixed cameras.
 
  Address  
  Corporate Author (up) Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes OR; 600.072;MV Approved no  
  Call Number Admin @ si @ MTR2016 Serial 2826  
Permanent link to this record
 

 
Author Santiago Segui; Michal Drozdzal; Guillem Pascual; Petia Radeva; Carolina Malagelada; Fernando Azpiroz; Jordi Vitria edit   pdf
url  openurl
  Title Generic Feature Learning for Wireless Capsule Endoscopy Analysis Type Journal Article
  Year 2016 Publication Computers in Biology and Medicine Abbreviated Journal CBM  
  Volume 79 Issue Pages 163-172  
  Keywords Wireless capsule endoscopy; Deep learning; Feature learning; Motility analysis  
  Abstract The interpretation and analysis of wireless capsule endoscopy (WCE) recordings is a complex task which requires sophisticated computer aided decision (CAD) systems to help physicians with video screening and, finally, with the diagnosis. Most CAD systems used in capsule endoscopy share a common system design, but use very different image and video representations. As a result, each time a new clinical application of WCE appears, a new CAD system has to be designed from the scratch. This makes the design of new CAD systems very time consuming. Therefore, in this paper we introduce a system for small intestine motility characterization, based on Deep Convolutional Neural Networks, which circumvents the laborious step of designing specific features for individual motility events. Experimental results show the superiority of the learned features over alternative classifiers constructed using state-of-the-art handcrafted features. In particular, it reaches a mean classification accuracy of 96% for six intestinal motility events, outperforming the other classifiers by a large margin (a 14% relative performance increase).  
  Address  
  Corporate Author (up) Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes OR; MILAB;MV; Approved no  
  Call Number Admin @ si @ SDP2016 Serial 2836  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: