|
Records |
Links |
|
Author ![sorted by Author field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
Carlo Gatta; Oriol Pujol; O. Rodriguez-Leor; J. M. Ferre; Petia Radeva |
![goto web page (via DOI) doi](http://refbase.cvc.uab.es/img/doi.gif)
|
|
Title |
Fast Rigid Registration of Vascular Structures in IVUS Sequences |
Type |
Journal Article |
|
Year |
2009 |
Publication |
IEEE Transactions on Information Technology in Biomedicine |
Abbreviated Journal |
|
|
|
Volume |
13 |
Issue |
6 |
Pages |
106-1011 |
|
|
Keywords |
|
|
|
Abstract |
Intravascular ultrasound (IVUS) technology permits visualization of high-resolution images of internal vascular structures. IVUS is a unique image-guiding tool to display longitudinal view of the vessels, and estimate the length and size of vascular structures with the goal of accurate diagnosis. Unfortunately, due to pulsatile contraction and expansion of the heart, the captured images are affected by different motion artifacts that make visual inspection difficult. In this paper, we propose an efficient algorithm that aligns vascular structures and strongly reduces the saw-shaped oscillation, simplifying the inspection of longitudinal cuts; it reduces the motion artifacts caused by the displacement of the catheter in the short-axis plane and the catheter rotation due to vessel tortuosity. The algorithm prototype aligns 3.16 frames/s and clearly outperforms state-of-the-art methods with similar computational cost. The speed of the algorithm is crucial since it allows to inspect the corrected sequence during patient intervention. Moreover, we improved an indirect methodology for IVUS rigid registration algorithm evaluation. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1089-7771 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB;HuPBA |
Approved |
no |
|
|
Call Number |
BCNPCL @ bcnpcl @ GPL2009 |
Serial |
1250 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
Carlo Gatta; Francesco Ciompi |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Stacked Sequential Scale-Space Taylor Context |
Type |
Journal Article |
|
Year |
2014 |
Publication |
IEEE Transactions on Pattern Analysis and Machine Intelligence |
Abbreviated Journal |
TPAMI |
|
|
Volume |
36 |
Issue |
8 |
Pages |
1694-1700 |
|
|
Keywords |
|
|
|
Abstract |
We analyze sequential image labeling methods that sample the posterior label field in order to gather contextual information. We propose an effective method that extracts local Taylor coefficients from the posterior at different scales. Results show that our proposal outperforms state-of-the-art methods on MSRC-21, CAMVID, eTRIMS8 and KAIST2 data sets. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0162-8828 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
LAMP; MILAB; 601.160; 600.079 |
Approved |
no |
|
|
Call Number |
Admin @ si @ GaC2014 |
Serial |
2466 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
Carlo Gatta; Eloi Puertas; Oriol Pujol |
![goto web page (via DOI) doi](http://refbase.cvc.uab.es/img/doi.gif)
|
|
Title |
Multi-Scale Stacked Sequential Learning |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Pattern Recognition |
Abbreviated Journal |
PR |
|
|
Volume |
44 |
Issue |
10-11 |
Pages |
2414-2416 |
|
|
Keywords |
Stacked sequential learning; Multiscale; Multiresolution; Contextual classification |
|
|
Abstract |
One of the most widely used assumptions in supervised learning is that data is independent and identically distributed. This assumption does not hold true in many real cases. Sequential learning is the discipline of machine learning that deals with dependent data such that neighboring examples exhibit some kind of relationship. In the literature, there are different approaches that try to capture and exploit this correlation, by means of different methodologies. In this paper we focus on meta-learning strategies and, in particular, the stacked sequential learning approach. The main contribution of this work is two-fold: first, we generalize the stacked sequential learning. This generalization reflects the key role of neighboring interactions modeling. Second, we propose an effective and efficient way of capturing and exploiting sequential correlations that takes into account long-range interactions by means of a multi-scale pyramidal decomposition of the predicted labels. Additionally, this new method subsumes the standard stacked sequential learning approach. We tested the proposed method on two different classification tasks: text lines classification in a FAQ data set and image classification. Results on these tasks clearly show that our approach outperforms the standard stacked sequential learning. Moreover, we show that the proposed method allows to control the trade-off between the detail and the desired range of the interactions. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB;HuPBA |
Approved |
no |
|
|
Call Number |
Admin @ si @ GPP2011 |
Serial |
1802 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
C. Malagelada; Fosca De Iorio; Fernando Azpiroz; Anna Accarino; Santiago Segui; Petia Radeva; Juan R. Malagelada |
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
New Insight Into Intestinal Motor Function via Noninvasive Endoluminal Image Analysis |
Type |
Journal |
|
Year |
2008 |
Publication |
Gastroenterology |
Abbreviated Journal |
|
|
|
Volume |
135 |
Issue |
4 |
Pages |
1155–1162 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB |
Approved |
no |
|
|
Call Number |
BCNPCL @ bcnpcl @ MDA2008 |
Serial |
1040 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, descending order (down)](http://refbase.cvc.uab.es/img/sort_desc.gif) |
C. Butakoff; Simone Balocco; F.M. Sukno; C. Hoogendoorn; C. Tobon-Gomez; G. Avegliano; A.F. Frangi |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title |
Left-ventricular Epi- and Endocardium Extraction from 3D Ultrasound Images Using an Automatically Constructed 3D ASM |
Type |
Journal Article |
|
Year |
2016 |
Publication |
Computer Methods in Biomechanics and Biomedical Engineering: Imaging and Visualization |
Abbreviated Journal |
CMBBE |
|
|
Volume |
4 |
Issue |
5 |
Pages |
265-280 |
|
|
Keywords |
ASM; cardiac segmentation; statistical model; shape model; 3D ultrasound; cardiac segmentation |
|
|
Abstract |
In this paper, we propose an automatic method for constructing an active shape model (ASM) to segment the complete cardiac left ventricle in 3D ultrasound (3DUS) images, which avoids costly manual landmarking. The automatic construction of the ASM has already been addressed in the literature; however, the direct application of these methods to 3DUS is hampered by a high level of noise and artefacts. Therefore, we propose to construct the ASM by fusing the multidetector computed tomography data, to learn the shape, with the artificially generated 3DUS, in order to learn the neighbourhood of the boundaries. Our artificial images were generated by two approaches: a faster one that does not take into account the geometry of the transducer, and a more comprehensive one, implemented in Field II toolbox. The segmentation accuracy of our ASM was evaluated on 20 patients with left-ventricular asynchrony, demonstrating plausibility of the approach. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2168-1163 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB |
Approved |
no |
|
|
Call Number |
Admin @ si @ BBS2016 |
Serial |
2449 |
|
Permanent link to this record |