TY - CONF AU - Joan M. Nuñez AU - Jorge Bernal AU - Miquel Ferrer AU - Fernando Vilariño A2 - CARE PY - 2014// TI - Impact of Keypoint Detection on Graph-based Characterization of Blood Vessels in Colonoscopy Videos BT - CARE workshop KW - Colonoscopy KW - Graph Matching KW - Biometrics KW - Vessel KW - Intersection N2 - We explore the potential of the use of blood vessels as anatomical landmarks for developing image registration methods in colonoscopy images. An unequivocal representation of blood vessels could be used to guide follow-up methods to track lesions over different interventions. We propose a graph-based representation to characterize network structures, such as blood vessels, based on the use of intersections and endpoints. We present a study consisting of the assessment of the minimal performance a keypoint detector should achieve so that the structure can still be recognized. Experimental results prove that, even by achieving a loss of 35% of the keypoints, the descriptive power of the associated graphs to the vessel pattern is still high enough to recognize blood vessels. L1 - http://refbase.cvc.uab.es/files/NBF2014.pdf UR - http://dx.doi.org/10.1007/978-3-319-13410-9_3 N1 - MV; DAG; 600.060; 600.047; 600.077;SIAI ID - Joan M. Nuñez2014 ER -