TY - CHAP AU - Debora Gil AU - Oriol Rodriguez-Leon AU - Petia Radeva AU - Aura Hernandez-Sabate PY - 2007// TI - Assessing Artery Motion Compensation in IVUS T2 - LNCS BT - Computer Analysis Of Images And Patterns T3 - Lecture Notes in Computer Science SP - 213 EP - 220 VL - 4673 PB - Springerlink CY - Heidelberg KW - validation standards KW - quality measures KW - IVUS motion compensation KW - conservation laws KW - Fourier development N2 - Cardiac dynamics suppression is a main issue for visual improvement and computation of tissue mechanical properties in IntraVascular UltraSound (IVUS). Although in recent times several motion compensation techniques have arisen, there is a lack of objective evaluation of motion reduction in in vivo pullbacks. We consider that the assessment protocol deserves special attention for the sake of a clinical applicability as reliable as possible. Our work focuses on defining a quality measure and a validation protocol assessing IVUS motion compensation. On the grounds of continuum mechanics laws we introduce a novel score measuring motion reduction in in vivo sequences. Synthetic experiments validate the proposed score as measure of motion parameters accuracy; while results in in vivo pullbacks show its reliability in clinical cases. SN - 978-3-540-74271-5 L1 - http://refbase.cvc.uab.es/files/GRR2007.pdf UR - http://dx.doi.org/10.1007/978-3-540-74272-2_27 N1 - IAM;MILAB ID - Debora Gil2007 ER -