TY - CONF AU - Oscar Camara AU - Estanislao Oubel AU - Gemma Piella AU - Simone Balocco AU - Mathieu De Craene AU - Alejandro F. Frangi A2 - FIMH PY - 2009// TI - Multi-sequence Registration of Cine, Tagged and Delay-Enhancement MRI with Shift Correction and Steerable Pyramid-Based Detagging T2 - LNCS BT - 5th International Conference on Functional Imaging and Modeling of the Heart SP - 330–338 VL - 5528 PB - Springer Berlin Heidelberg N2 - In this work, we present a registration framework for cardiac cine MRI (cMRI), tagged (tMRI) and delay-enhancement MRI (deMRI), where the two main issues to find an accurate alignment between these images have been taking into account: the presence of tags in tMRI and respiration artifacts in all sequences. A steerable pyramid image decomposition has been used for detagging purposes since it is suitable to extract high-order oriented structures by directional adaptive filtering. Shift correction of cMRI is achieved by firstly maximizing the similarity between the Long Axis and Short Axis cMRI. Subsequently, these shift-corrected images are used as target images in a rigid registration procedure with their corresponding tMRI/deMRI in order to correct their shift. The proposed registration framework has been evaluated by 840 registration tests, considerably improving the alignment of the MR images (mean RMS error of 2.04mm vs. 5.44mm). SN - 0302-9743 SN - 978-3-642-01931-9 UR - http://dx.doi.org/10.1007/978-3-642-01932-6_36 N1 - MILAB ID - Oscar Camara2009 ER -