PT Unknown AU Francesco Ciompi Simone Balocco Carles Caus J. Mauri Petia Radeva TI Stent shape estimation through a comprehensive interpretation of intravascular ultrasound images BT 16th International Conference on Medical Image Computing and Computer Assisted Intervention PY 2013 BP 345 EP 352 VL 8150 IS 2 DI 10.1007/978-3-642-40763-5_43 AB We present a method for automatic struts detection and stent shape estimation in cross-sectional intravascular ultrasound images. A stent shape is first estimated through a comprehensive interpretation of the vessel morphology, performed using a supervised context-aware multi-class classification scheme. Then, the successive strut identification exploits both local appearance and the defined stent shape. The method is tested on 589 images obtained from 80 patients, achieving a F-measure of 74.1% and an averaged distance between manual and automatic struts of 0.10 mm. ER