%0 Conference Proceedings %T A Holistic Approach for the Detection of Media-Adventitia Border in IVUS %A Francesco Ciompi %A Oriol Pujol %A Carlo Gatta %A Xavier Carrillo %A Josepa Mauri %A Petia Radeva %B 14th International Conference on Medical Image Computing and Computer Assisted Intervention %D 2011 %V 6893 %I Springer Berlin Heidelberg %@ 0302-9743 %@ 978-3-642-23625-9 %F Francesco Ciompi2011 %O MILAB;HuPBA %O exported from refbase (http://refbase.cvc.uab.es/show.php?record=1739), last updated on Mon, 21 Jan 2019 09:56:35 +0100 %X In this paper we present a methodology for the automatic detection of media-adventitia border (MAb) in Intravascular Ultrasound. A robust computation of the MAb is achieved through a holistic approach where the position of the MAb with respect to other tissues of the vessel is used. A learned quality measure assures that the resulting MAb is optimal with respect to all other tissues. The mean distance error computed through a set of 140 images is 0.2164 (±0.1326) mm. %U http://dx.doi.org/10.1007/978-3-642-23626-6_51 %P 401-408