2011 |
|
Sergio Escalera, Ana Puig, Oscar Amoros, & Maria Salamo. (2011). Intelligent GPGPU Classification in Volume Visualization: a framework based on Error-Correcting Output Codes. CGF - Computer Graphics Forum, 30(7), 2107–2115.
Abstract: IF JCR 1.455 2010 25/99
In volume visualization, the definition of the regions of interest is inherently an iterative trial-and-error process finding out the best parameters to classify and render the final image. Generally, the user requires a lot of expertise to analyze and edit these parameters through multi-dimensional transfer functions. In this paper, we present a framework of intelligent methods to label on-demand multiple regions of interest. These methods can be split into a two-level GPU-based labelling algorithm that computes in time of rendering a set of labelled structures using the Machine Learning Error-Correcting Output Codes (ECOC) framework. In a pre-processing step, ECOC trains a set of Adaboost binary classifiers from a reduced pre-labelled data set. Then, at the testing stage, each classifier is independently applied on the features of a set of unlabelled samples and combined to perform multi-class labelling. We also propose an alternative representation of these classifiers that allows to highly parallelize the testing stage. To exploit that parallelism we implemented the testing stage in GPU-OpenCL. The empirical results on different data sets for several volume structures shows high computational performance and classification accuracy.
|
|
|
Sergio Escalera, David Masip, Eloi Puertas, Petia Radeva, & Oriol Pujol. (2011). Online Error-Correcting Output Codes. PRL - Pattern Recognition Letters, 32(3), 458–467.
Abstract: IF JCR CCIA 1.303 2009 54/103
This article proposes a general extension of the error correcting output codes framework to the online learning scenario. As a result, the final classifier handles the addition of new classes independently of the base classifier used. In particular, this extension supports the use of both online example incremental and batch classifiers as base learners. The extension of the traditional problem independent codings one-versus-all and one-versus-one is introduced. Furthermore, two new codings are proposed, unbalanced online ECOC and a problem dependent online ECOC. This last online coding technique takes advantage of the problem data for minimizing the number of dichotomizers used in the ECOC framework while preserving a high accuracy. These techniques are validated on an online setting of 11 data sets from UCI database and applied to two real machine vision applications: traffic sign recognition and face recognition. As a result, the online ECOC techniques proposed provide a feasible and robust way for handling new classes using any base classifier.
|
|
|
Victor Ponce, Mario Gorga, Xavier Baro, Petia Radeva, & Sergio Escalera. (2011). Análisis de la expresión oral y gestual en proyectos fin de carrera vía un sistema de visión artificial. ReVisión, 4(1).
Abstract: La comunicación y expresión oral es una competencia de especial relevancia en el EEES. No obstante, en muchas enseñanzas superiores la puesta en práctica de esta competencia ha sido relegada principalmente a la presentación de proyectos fin de carrera. Dentro de un proyecto de innovación docente, se ha desarrollado una herramienta informática para la extracción de información objetiva para el análisis de la expresión oral y gestual de los alumnos. El objetivo es dar un “feedback” a los estudiantes que les permita mejorar la calidad de sus presentaciones. El prototipo inicial que se presenta en este trabajo permite extraer de forma automática información audiovisual y analizarla mediante técnicas de aprendizaje. El sistema ha sido aplicado a 15 proyectos fin de carrera y 15 exposiciones dentro de una asignatura de cuarto curso. Los resultados obtenidos muestran la viabilidad del sistema para sugerir factores que ayuden tanto en el éxito de la comunicación así como en los criterios de evaluación.
|
|
|
Xavier Carrillo, E Fernandez-Nofrerias, Francesco Ciompi, O. Rodriguez-Leor, Petia Radeva, Neus Salvatella, et al. (2011). Changes in Radial Artery Volume Assessed Using Intravascular Ultrasound: A Comparison of Two Vasodilator Regimens in Transradial Coronary Intervention. JOIC - Journal of Invasive Cardiology, 23(10), 401–404.
Abstract: OBJECTIVES:
This study used intravascular ultrasound (IVUS) to evaluate radial artery volume changes after intraarterial administration of nitroglycerin and/or verapamil.
BACKGROUND:
Radial artery spasm, which is associated with radial artery size, is the main limitation of the transradial approach in percutaneous coronary interventions (PCI).
METHODS:
This prospective, randomized study compared the effect of two intra-arterial vasodilator regimens on radial artery volume: 0.2 mg of nitroglycerin plus 2.5 mg of verapamil (Group 1; n = 15) versus 2.5 mg of verapamil alone (Group 2; n = 15). Radial artery lumen volume was assessed using IVUS at two time points: at baseline (5 minutes after sheath insertion) and post-vasodilator (1 minute after drug administration). The luminal volume of the radial artery was computed using ECOC Random Fields (ECOC-RF), a technique used for automatic segmentation of luminal borders in longitudinal cut images from IVUS sequences.
RESULTS:
There was a significant increase in arterial lumen volume in both groups, with an increase from 451 ± 177 mm³ to 508 ± 192 mm³ (p = 0.001) in Group 1 and from 456 ± 188 mm³ to 509 ± 170 mm³ (p = 0.001) in Group 2. There were no significant differences between the groups in terms of absolute volume increase (58 mm³ versus 53 mm³, respectively; p = 0.65) or in relative volume increase (14% versus 20%, respectively; p = 0.69).
CONCLUSIONS:
Administration of nitroglycerin plus verapamil or verapamil alone to the radial artery resulted in similar increases in arterial lumen volume according to ECOC-RF IVUS measurements.
Keywords: radial; vasodilator treatment; percutaneous coronary intervention; IVUS; volumetric IVUS analysis
|
|
2010 |
|
David Rotger, Petia Radeva, & N. Bruining. (2010). Automatic Detection of Bioabsorbable Coronary Stents in IVUS Images using a Cascade of Classifiers. TITB - IEEE Transactions on Information Technology in Biomedicine, 14(2), 535 – 537.
Abstract: Bioabsorbable drug-eluting coronary stents present a very promising improvement to the common metallic ones solving some of the most important problems of stent implantation: the late restenosis. These stents made of poly-L-lactic acid cause a very subtle acoustic shadow (compared to the metallic ones) making difficult the automatic detection and measurements in images. In this paper, we propose a novel approach based on a cascade of GentleBoost classifiers to detect the stent struts using structural features to code the information of the different subregions of the struts. A stochastic gradient descent method is applied to optimize the overall performance of the detector. Validation results of struts detection are very encouraging with an average F-measure of 81%.
|
|