Sergio Vera, Miguel Angel Gonzalez Ballester, & Debora Gil. (2012). "Optimal Medial Surface Generation for Anatomical Volume Representations " In MichaelW. David and Vannier H. and H. Yoshida (Ed.), Abdominal Imaging. Computational and Clinical Applications (Vol. 7601, pp. 265–273). Lecture Notes in Computer Science. Springer Berlin Heidelberg.
Abstract: Medial representations are a widely used technique in abdominal organ shape representation and parametrization. Those methods require good medial manifolds as a starting point. Any medial
surface used to parametrize a volume should be simple enough to allow an easy manipulation and complete enough to allow an accurate reconstruction of the volume. Obtaining good quality medial
surfaces is still a problem with current iterative thinning methods. This forces the usage of generic, pre-calculated medial templates that are adapted to the final shape at the cost of a drop in volume reconstruction.
This paper describes an operator for generation of medial structures that generates clean and complete manifolds well suited for their further use in medial representations of abdominal organ volumes. While being simpler than thinning surfaces, experiments show its high performance in volume reconstruction and preservation of medial surface main branching topology.
Keywords: Medial surface representation; volume reconstruction
|
|
|
Hanne Kause, Aura Hernandez-Sabate, Patricia Marquez, Andrea Fuster, Luc Florack, Hans van Assen, et al. (2015). "Confidence Measures for Assessing the HARP Algorithm in Tagged Magnetic Resonance Imaging " In Statistical Atlases and Computational Models of the Heart. Revised selected papers of Imaging and Modelling Challenges 6th International Workshop, STACOM 2015, Held in Conjunction with MICCAI 2015 (Vol. 9534, pp. 69–79). Springer International Publishing.
Abstract: Cardiac deformation and changes therein have been linked to pathologies. Both can be extracted in detail from tagged Magnetic Resonance Imaging (tMRI) using harmonic phase (HARP) images. Although point tracking algorithms have shown to have high accuracies on HARP images, these vary with position. Detecting and discarding areas with unreliable results is crucial for use in clinical support systems. This paper assesses the capability of two confidence measures (CMs), based on energy and image structure, for detecting locations with reduced accuracy in motion tracking results. These CMs were tested on a database of simulated tMRI images containing the most common artifacts that may affect tracking accuracy. CM performance is assessed based on its capability for HARP tracking error bounding and compared in terms of significant differences detected using a multi comparison analysis of variance that takes into account the most influential factors on HARP tracking performance. Results showed that the CM based on image structure was better suited to detect unreliable optical flow vectors. In addition, it was shown that CMs can be used to detect optical flow vectors with large errors in order to improve the optical flow obtained with the HARP tracking algorithm.
|
|
|
Carles Sanchez, F. Javier Sanchez, Antoni Rosell, & Debora Gil. (2012). "An illumination model of the trachea appearance in videobronchoscopy images " In Image Analysis and Recognition (Vol. 7325, pp. 313–320). Lecture Notes in Computer Science. Springer Berlin Heidelberg.
Abstract: Videobronchoscopy is a medical imaging technique that allows interactive navigation inside the respiratory pathways. This imaging modality provides realistic images and allows non-invasive minimal intervention procedures. Tracheal procedures are routinary interventions that require assessment of the percentage of obstructed pathway for injury (stenosis) detection. Visual assessment in videobronchoscopic sequences requires high expertise of trachea anatomy and is prone to human error.
This paper introduces an automatic method for the estimation of steneosed trachea percentage reduction in videobronchoscopic images. We look for tracheal rings , whose deformation determines the degree of obstruction. For ring extraction , we present a ring detector based on an illumination and appearance model. This model allows us to parametrise the ring detection. Finally, we can infer optimal estimation parameters for any video resolution.
Keywords: Bronchoscopy, tracheal ring, stenosis assesment, trachea appearance model, segmentation
|
|
|
Josep Llados, Ernest Valveny, Gemma Sanchez, & Enric Marti. (2002). "Symbol recognition: current advances and perspectives " In Dorothea Blostein and Young- Bin Kwon (Ed.), Graphics Recognition Algorithms And Applications (Vol. 2390, pp. 104–128). Lecture Notes in Computer Science. Springer-Verlag.
Abstract: The recognition of symbols in graphic documents is an intensive research activity in the community of pattern recognition and document analysis. A key issue in the interpretation of maps, engineering drawings, diagrams, etc. is the recognition of domain dependent symbols according to a symbol database. In this work we first review the most outstanding symbol recognition methods from two different points of view: application domains and pattern recognition methods. In the second part of the paper, open and unaddressed problems involved in symbol recognition are described, analyzing their current state of art and discussing future research challenges. Thus, issues such as symbol representation, matching, segmentation, learning, scalability of recognition methods and performance evaluation are addressed in this work. Finally, we discuss the perspectives of symbol recognition concerning to new paradigms such as user interfaces in handheld computers or document database and WWW indexing by graphical content.
|
|
|
F.Guirado, Ana Ripoll, C.Roig, Aura Hernandez-Sabate, & Emilio Luque. (2006). "Exploiting Throughput for Pipeline Execution in Streaming Image Processing Applications " In UAB, E. N. W, & et al. (Eds.), Euro-Par 2006 Parallel Processing (Vol. 4128, pp. 1095–1105). Lecture Notes In Computer Science. Dresden, Germany (European Union): Springer-Verlag Berlin Heidelberg.
Abstract: There is a large range of image processing applications that act on an input sequence of image frames that are continuously received. Throughput is a key performance measure to be optimized when execu- ting them. In this paper we propose a new task replication methodology for optimizing throughput for an image processing application in the field of medicine. The results show that by applying the proposed methodo- logy we are able to achieve the desired throughput in all cases, in such a way that the input frames can be processed at any given rate.
Keywords: 12th International Euro–Par Conference
|
|
|
Jaume Garcia, Petia Radeva, & Francesc Carreras. (2004). "Combining Spectral and Active Shape methods to Track Tagged MRI " In Recent Advances in Artificial Intelligence Research and Development (pp. 37–44). IOS Press.
Abstract: Tagged magnetic resonance is a very usefull and unique tool that provides a complete local and global knowledge of the left ventricle (LV) motion. In this article we introduce a method capable of tracking and segmenting the LV. Spectral methods are applied in order to obtain the so called HARP images which encode information about movement and are the base for LV point-tracking. For segmentation we use Active Shapes (ASM) that model LV shape variation in order to overcome possible local misplacements of the boundary. We finally show experiments on both synthetic and real data which appear to be very promising.
Keywords: MR; tagged MR; ASM; LV segmentation; motion estimation.
|
|
|
Debora Gil, F. Javier Sanchez, Gloria Fernandez Esparrach, & Jorge Bernal. (2015). "3D Stable Spatio-temporal Polyp Localization in Colonoscopy Videos " In Computer-Assisted and Robotic Endoscopy. Revised selected papers of Second International Workshop, CARE 2015, Held in Conjunction with MICCAI 2015 (Vol. 9515, pp. 140–152).
Abstract: Computational intelligent systems could reduce polyp miss rate in colonoscopy for colon cancer diagnosis and, thus, increase the efficiency of the procedure. One of the main problems of existing polyp localization methods is a lack of spatio-temporal stability in their response. We propose to explore the response of a given polyp localization across temporal windows in order to select
those image regions presenting the highest stable spatio-temporal response.
Spatio-temporal stability is achieved by extracting 3D watershed regions on the
temporal window. Stability in localization response is statistically determined by analysis of the variance of the output of the localization method inside each 3D region. We have explored the benefits of considering spatio-temporal stability in two different tasks: polyp localization and polyp detection. Experimental results indicate an average improvement of 21:5% in polyp localization and 43:78% in polyp detection.
Keywords: Colonoscopy, Polyp Detection, Polyp Localization, Region Extraction, Watersheds
|
|
|
Sergio Vera, Debora Gil, Agnes Borras, F. Javier Sanchez, Frederic Perez, Marius G. Linguraru, et al. (2012). "Computation and Evaluation of Medial Surfaces for Shape Representation of Abdominal Organs " In H. Yoshida et al (Ed.), Workshop on Computational and Clinical Applications in Abdominal Imaging (Vol. 7029, 223–230). Lecture Notes in Computer Science. Berlin: Springer Link.
Abstract: Medial representations are powerful tools for describing and parameterizing the volumetric shape of anatomical structures. Existing methods show excellent results when applied to 2D
objects, but their quality drops across dimensions. This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial
manifolds that avoid degenerated medial axis segments; second, we introduce an energy based method which performs independently of the dimension. We evaluate quantitatively the performance of our
method with respect to existing approaches, by applying them to synthetic shapes of known medial geometry. Finally, we show results on shape representation of multiple abdominal organs,
exploring the use of medial manifolds for the representation of multi-organ relations.
Keywords: medial manifolds, abdomen.
|
|
|
Debora Gil, Jordi Gonzalez, & Gemma Sanchez (Eds.). (2007)." Computer Vision: Advances in Research and Development" . 2. Bellaterra (Spain): UAB.
|
|
|
Jaume Garcia. (2009). "Statistical Models of the Architecture and Function of the Left Ventricle " (Debora Gil, Ed.). Ph.D. thesis, Ediciones Graficas Rey, .
Abstract: Cardiovascular Diseases, specially those affecting the Left Ventricle (LV), are the leading cause of death in developed countries with approximately a 30% of all global deaths. In order to address this public health concern, physicians focus on diagnosis and therapy planning. On one hand, early and accurate detection of Regional Wall Motion Abnormalities (RWMA) significantly contributes to a quick diagnosis and prevents the patient to reach more severe stages. On the other hand, a thouroughly knowledge of the normal gross anatomy of the LV, as well as, the distribution of its muscular fibers is crucial for designing specific interventions and therapies (such as pacemaker implanction). Statistical models obtained from the analysis of different imaging modalities allow the computation of the normal ranges of variation within a given population. Normality models are a valuable tool for the definition of objective criterions quantifying the degree of (anomalous) deviation of the LV function and anatomy for a given subject. The creation of statistical models involve addressing three main issues: extraction of data from images, definition of a common domain for comparison of data across patients and designing appropriate statistical analysis schemes. In this PhD thesis we present generic image processing tools for the creation of statistical models of the LV anatomy and function. On one hand, we use differential geometry concepts to define a computational framework (the Normalized Parametric Domain, NPD) suitable for the comparison and fusion of several clinical scores obtained over the LV. On the other hand, we present a variational approach (the Harmonic Phase Flow, HPF) for the estimation of myocardial motion that provides dense and continuous vector fields without overestimating motion at injured areas. These tools are used for the creation of statistical models. Regarding anatomy, we obtain an atlas jointly modelling, both, LV gross anatomy and fiber architecture. Regarding function, we compute normality patterns of scores characterizing the (global and local) LV function and explore, for the first time, the configuration of local scores better suited for RWMA detection.
|
|