<?xml version="1.0" encoding="UTF-8" ?>

<modsCollection xmlns="http://www.loc.gov/mods/v3">
	<mods version="3.2">
		<titleInfo>
			<title>What a difference in biomechanics cardiac fiber makes</title>
		</titleInfo>
		<name type="personal">
			<namePart type="family">Debora Gil</namePart>
			<role>
				<roleTerm authority="marcrelator" type="text">author</roleTerm>
			</role>
		</name>
		<name type="personal">
			<namePart type="family">Agnes Borras</namePart>
			<role>
				<roleTerm authority="marcrelator" type="text">author</roleTerm>
			</role>
		</name>
		<name type="personal">
			<namePart type="family">Ruth Aris</namePart>
			<role>
				<roleTerm authority="marcrelator" type="text">author</roleTerm>
			</role>
		</name>
		<name type="personal">
			<namePart type="family">Mariano Vazquez</namePart>
			<role>
				<roleTerm authority="marcrelator" type="text">author</roleTerm>
			</role>
		</name>
		<name type="personal">
			<namePart type="family">Pierre Lafortune</namePart>
			<role>
				<roleTerm authority="marcrelator" type="text">author</roleTerm>
			</role>
		</name>
		<name type="personal">
			<namePart type="family">Guillame Houzeaux</namePart>
			<role>
				<roleTerm authority="marcrelator" type="text">author</roleTerm>
			</role>
		</name>
		<originInfo>
			<dateIssued>2012</dateIssued>
			<publisher>Springer Berlin Heidelberg</publisher>
		</originInfo>
		<abstract>Computational simulations of the heart are a powerful tool for a comprehensive understanding of cardiac function and its intrinsic relationship with its muscular architecture. Cardiac biomechanical models require a vector field representing the orientation of cardiac fibers. A wrong orientation of the fibers can lead to a
non-realistic simulation of the heart functionality. In this paper we explore the impact of the fiber information on the simulated biomechanics of cardiac muscular anatomy. We have used the John Hopkins database to perform a biomechanical simulation using both a synthetic benchmark fiber distribution and the data obtained experimentally from DTI. Results illustrate how differences in fiber orientation affect heart deformation along cardiac cycle.</abstract>
		<note>IAM</note>
		<note>exported from refbase (http://refbase.cvc.uab.es/show.php?record=1987), last updated on Thu, 30 Jun 2016 13:33:56 +0200</note>
		<typeOfResource>text</typeOfResource>
		<location>
			<url displayLabel="Electronic full text" access="raw object">http://refbase.cvc.uab.es/files/GBA2012.pdf</url>
		</location>
		<identifier type="doi">10.1007/978-3-642-36961-2_29</identifier>
		<identifier type="local">IAM @ iam @ GBA2012</identifier>
		<relatedItem type="host">
			<titleInfo>
				<title>Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges</title>
			</titleInfo>
			<name type="conference">
				<namePart>STACOM</namePart>
			</name>
			<originInfo>
				<dateIssued>2012</dateIssued>
				<publisher>Springer Berlin Heidelberg</publisher>
			</originInfo>
			<genre authority="marcgt">conference publication</genre>
			<part>
				<detail type="volume">
					<number>7746</number>
				</detail>
				<extent unit="page">
					<start>253</start>
					<end>260</end>
				</extent>
			</part>
			<identifier type="isbn">978-3-642-36960-5</identifier>
			<identifier type="issn">0302-9743</identifier>
		</relatedItem>
	</mods>
</modsCollection>