toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Record Links
Author Arash Akbarinia; Karl R. Gegenfurtner edit  doi
openurl 
  Title Metameric Mismatching in Natural and Artificial Reflectances Type Journal Article
  Year 2017 Publication Journal of Vision Abbreviated Journal JV  
  Volume 17 Issue 10 Pages 390-390  
  Keywords Metamer; colour perception; spectral discrimination; photoreceptors  
  Abstract The human visual system and most digital cameras sample the continuous spectral power distribution through three classes of receptors. This implies that two distinct spectral reflectances can result in identical tristimulus values under one illuminant and differ under another – the problem of metamer mismatching. It is still debated how frequent this issue arises in the real world, using naturally occurring reflectance functions and common illuminants.

We gathered more than ten thousand spectral reflectance samples from various sources, covering a wide range of environments (e.g., flowers, plants, Munsell chips) and evaluated their responses under a number of natural and artificial source of lights. For each pair of reflectance functions, we estimated the perceived difference using the CIE-defined distance ΔE2000 metric in Lab color space.

The degree of metamer mismatching depended on the lower threshold value l when two samples would be considered to lead to equal sensor excitations (ΔE < l), and on the higher threshold value h when they would be considered different. For example, for l=h=1, we found that 43.129 comparisons out of a total of 6×107 pairs would be considered metameric (1 in 104). For l=1 and h=5, this number reduced to 705 metameric pairs (2 in 106). Extreme metamers, for instance l=1 and h=10, were rare (22 pairs or 6 in 108), as were instances where the two members of a metameric pair would be assigned to different color categories. Not unexpectedly, we observed variations among different reflectance databases and illuminant spectra with more frequency under artificial illuminants than natural ones.

Overall, our numbers are not very different from those obtained earlier (Foster et al, JOSA A, 2006). However, our results also show that the degree of metamerism is typically not very strong and that category switches hardly ever occur.
 
  Address Florida, USA; May 2017  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (up) NEUROBIT; no menciona Approved no  
  Call Number Admin @ si @ AkG2017 Serial 2899  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: