toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author Fosca De Iorio; C. Malagelada; Fernando Azpiroz; M. Maluenda; C. Violanti; Laura Igual; Jordi Vitria; Juan R. Malagelada edit  doi
openurl 
  Title Intestinal motor activity, endoluminal motion and transit Type Journal Article
  Year 2009 Publication Neurogastroenterology & Motility Abbreviated Journal NEUMOT  
  Volume 21 Issue 12 Pages 1264–e119  
  Keywords  
  Abstract (up) A programme for evaluation of intestinal motility has been recently developed based on endoluminal image analysis using computer vision methodology and machine learning techniques. Our aim was to determine the effect of intestinal muscle inhibition on wall motion, dynamics of luminal content and transit in the small bowel. Fourteen healthy subjects ingested the endoscopic capsule (Pillcam, Given Imaging) in fasting conditions. Seven of them received glucagon (4.8 microg kg(-1) bolus followed by a 9.6 microg kg(-1) h(-1) infusion during 1 h) and in the other seven, fasting activity was recorded, as controls. This dose of glucagon has previously shown to inhibit both tonic and phasic intestinal motor activity. Endoluminal image and displacement was analyzed by means of a computer vision programme specifically developed for the evaluation of muscular activity (contractile and non-contractile patterns), intestinal contents, endoluminal motion and transit. Thirty-minute periods before, during and after glucagon infusion were analyzed and compared with equivalent periods in controls. No differences were found in the parameters measured during the baseline (pretest) periods when comparing glucagon and control experiments. During glucagon infusion, there was a significant reduction in contractile activity (0.2 +/- 0.1 vs 4.2 +/- 0.9 luminal closures per min, P < 0.05; 0.4 +/- 0.1 vs 3.4 +/- 1.2% of images with radial wrinkles, P < 0.05) and a significant reduction of endoluminal motion (82 +/- 9 vs 21 +/- 10% of static images, P < 0.05). Endoluminal image analysis, by means of computer vision and machine learning techniques, can reliably detect reduced intestinal muscle activity and motion.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes OR;MILAB;MV Approved no  
  Call Number BCNPCL @ bcnpcl @ DMA2009 Serial 1251  
Permanent link to this record
 

 
Author Jorge Bernal; Aymeric Histace; Marc Masana; Quentin Angermann; Cristina Sanchez Montes; Cristina Rodriguez de Miguel; Maroua Hammami; Ana Garcia Rodriguez; Henry Cordova; Olivier Romain; Gloria Fernandez Esparrach; Xavier Dray; F. Javier Sanchez edit   pdf
doi  openurl
  Title GTCreator: a flexible annotation tool for image-based datasets Type Journal Article
  Year 2019 Publication International Journal of Computer Assisted Radiology and Surgery Abbreviated Journal IJCAR  
  Volume 14 Issue 2 Pages 191–201  
  Keywords Annotation tool; Validation Framework; Benchmark; Colonoscopy; Evaluation  
  Abstract (up) Abstract Purpose: Methodology evaluation for decision support systems for health is a time consuming-task. To assess performance of polyp detection
methods in colonoscopy videos, clinicians have to deal with the annotation
of thousands of images. Current existing tools could be improved in terms of
exibility and ease of use. Methods:We introduce GTCreator, a exible annotation tool for providing image and text annotations to image-based datasets.
It keeps the main basic functionalities of other similar tools while extending
other capabilities such as allowing multiple annotators to work simultaneously
on the same task or enhanced dataset browsing and easy annotation transfer aiming to speed up annotation processes in large datasets. Results: The
comparison with other similar tools shows that GTCreator allows to obtain
fast and precise annotation of image datasets, being the only one which offers
full annotation editing and browsing capabilites. Conclusions: Our proposed
annotation tool has been proven to be efficient for large image dataset annota-
tion, as well as showing potential of use in other stages of method evaluation
such as experimental setup or results analysis.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MV; 600.096; 600.109; 600.119; 601.305 Approved no  
  Call Number Admin @ si @ BHM2019 Serial 3163  
Permanent link to this record
 

 
Author Sergio Escalera; Oriol Pujol; Petia Radeva; Jordi Vitria; Maria Teresa Anguera edit  doi
openurl 
  Title Automatic Detection of Dominance and Expected Interest Type Journal Article
  Year 2010 Publication EURASIP Journal on Advances in Signal Processing Abbreviated Journal EURASIPJ  
  Volume Issue Pages 12  
  Keywords  
  Abstract (up) Article ID 491819
Social Signal Processing is an emergent area of research that focuses on the analysis of social constructs. Dominance and interest are two of these social constructs. Dominance refers to the level of influence a person has in a conversation. Interest, when referred in terms of group interactions, can be defined as the degree of engagement that the members of a group collectively display during their interaction. In this paper, we argue that only using behavioral motion information, we are able to predict the interest of observers when looking at face-to-face interactions as well as the dominant people. First, we propose a simple set of movement-based features from body, face, and mouth activity in order to define a higher set of interaction indicators. The considered indicators are manually annotated by observers. Based on the opinions obtained, we define an automatic binary dominance detection problem and a multiclass interest quantification problem. Error-Correcting Output Codes framework is used to learn to rank the perceived observer's interest in face-to-face interactions meanwhile Adaboost is used to solve the dominant detection problem. The automatic system shows good correlation between the automatic categorization results and the manual ranking made by the observers in both dominance and interest detection problems.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1110-8657 ISBN Medium  
  Area Expedition Conference  
  Notes OR;MILAB;HUPBA;MV Approved no  
  Call Number BCNPCL @ bcnpcl @ EPR2010d Serial 1283  
Permanent link to this record
 

 
Author Gloria Fernandez Esparrach; Jorge Bernal; Maria Lopez Ceron; Henry Cordova; Cristina Sanchez Montes; Cristina Rodriguez de Miguel; F. Javier Sanchez edit   pdf
doi  openurl
  Title Exploring the clinical potential of an automatic colonic polyp detection method based on the creation of energy maps Type Journal Article
  Year 2016 Publication Endoscopy Abbreviated Journal END  
  Volume 48 Issue 9 Pages 837-842  
  Keywords  
  Abstract (up) Background and aims: Polyp miss-rate is a drawback of colonoscopy that increases significantly in small polyps. We explored the efficacy of an automatic computer vision method for polyp detection.
Methods: Our method relies on a model that defines polyp boundaries as valleys of image intensity. Valley information is integrated into energy maps which represent the likelihood of polyp presence.
Results: In 24 videos containing polyps from routine colonoscopies, all polyps were detected in at least one frame. Mean values of the maximum of energy map were higher in frames with polyps than without (p<0.001). Performance improved in high quality frames (AUC= 0.79, 95%CI: 0.70-0.87 vs 0.75, 95%CI: 0.66-0.83). Using 3.75 as maximum threshold value, sensitivity and specificity for detection of polyps were 70.4% (95%CI: 60.3-80.8) and 72.4% (95%CI: 61.6-84.6), respectively.
Conclusion: Energy maps showed a good performance for colonic polyp detection. This indicates a potential applicability in clinical practice.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MV; Approved no  
  Call Number Admin @ si @FBL2016 Serial 2778  
Permanent link to this record
 

 
Author Cristina Sanchez Montes; F. Javier Sanchez; Jorge Bernal; Henry Cordova; Maria Lopez Ceron; Miriam Cuatrecasas; Cristina Rodriguez de Miguel; Ana Garcia Rodriguez; Rodrigo Garces Duran; Maria Pellise; Josep Llach; Gloria Fernandez Esparrach edit   pdf
doi  openurl
  Title Computer-aided Prediction of Polyp Histology on White-Light Colonoscopy using Surface Pattern Analysis Type Journal Article
  Year 2019 Publication Endoscopy Abbreviated Journal END  
  Volume 51 Issue 3 Pages 261-265  
  Keywords  
  Abstract (up) Background and study aims: To evaluate a new computational histology prediction system based on colorectal polyp textural surface patterns using high definition white light images.
Patients and methods: Textural elements (textons) were characterized according to their contrast with respect to the surface, shape and number of bifurcations, assuming that dysplastic polyps are associated with highly contrasted, large tubular patterns with some degree of bifurcation. Computer-aided diagnosis (CAD) was compared with pathological diagnosis and the diagnosis by the endoscopists using Kudo and NICE classification.
Results: Images of 225 polyps were evaluated (142 dysplastic and 83 non-dysplastic). CAD system correctly classified 205 (91.1%) polyps, 131/142 (92.3%) dysplastic and 74/83 (89.2%) non-dysplastic. For the subgroup of 100 diminutive (<5 mm) polyps, CAD correctly classified 87 (87%) polyps, 43/50 (86%) dysplastic and 44/50 (88%) non-dysplastic. There were not statistically significant differences in polyp histology prediction based on CAD system and on endoscopist assessment.
Conclusion: A computer vision system based on the characterization of the polyp surface in the white light accurately predicts colorectal polyp histology.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MV; 600.096; 600.119; 600.075 Approved no  
  Call Number Admin @ si @ SSB2019 Serial 3164  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: