toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author Ariel Amato edit  openurl
  Title Moving cast shadow detection Type Journal Article
  Year 2014 Publication Electronic letters on computer vision and image analysis Abbreviated Journal (up) ELCVIA  
  Volume 13 Issue 2 Pages 70-71  
  Keywords  
  Abstract Motion perception is an amazing innate ability of the creatures on the planet. This adroitness entails a functional advantage that enables species to compete better in the wild. The motion perception ability is usually employed at different levels, allowing from the simplest interaction with the ’physis’ up to the most transcendental survival tasks. Among the five classical perception system , vision is the most widely used in the motion perception field. Millions years of evolution have led to a highly specialized visual system in humans, which is characterized by a tremendous accuracy as well as an extraordinary robustness. Although humans and an immense diversity of species can distinguish moving object with a seeming simplicity, it has proven to be a difficult and non trivial problem from a computational perspective. In the field of Computer Vision, the detection of moving objects is a challenging and fundamental research area. This can be referred to as the ’origin’ of vast and numerous vision-based research sub-areas. Nevertheless, from the bottom to the top of this hierarchical analysis, the foundations still relies on when and where motion has occurred in an image. Pixels corresponding to moving objects in image sequences can be identified by measuring changes in their values. However, a pixel’s value (representing a combination of color and brightness) could also vary due to other factors such as: variation in scene illumination, camera noise and nonlinear sensor responses among others. The challenge lies in detecting if the changes in pixels’ value are caused by a genuine object movement or not. An additional challenging aspect in motion detection is represented by moving cast shadows. The paradox arises because a moving object and its cast shadow share similar motion patterns. However, a moving cast shadow is not a moving object. In fact, a shadow represents a photometric illumination effect caused by the relative position of the object with respect to the light sources. Shadow detection methods are mainly divided in two domains depending on the application field. One normally consists of static images where shadows are casted by static objects, whereas the second one is referred to image sequences where shadows are casted by moving objects. For the first case, shadows can provide additional geometric and semantic cues about shape and position of its casting object as well as the localization of the light source. Although the previous information can be extracted from static images as well as video sequences, the main focus in the second area is usually change detection, scene matching or surveillance. In this context, a shadow can severely affect with the analysis and interpretation of the scene. The work done in the thesis is focused on the second case, thus it addresses the problem of detection and removal of moving cast shadows in video sequences in order to enhance the detection of moving object.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes ISE Approved no  
  Call Number Admin @ si @ Ama2014 Serial 2870  
Permanent link to this record
 

 
Author Wenwen Fu; Zhihong An; Wendong Huang; Haoran Sun; Wenjuan Gong; Jordi Gonzalez edit  url
openurl 
  Title A Spatio-Temporal Spotting Network with Sliding Windows for Micro-Expression Detection Type Journal Article
  Year 2023 Publication Electronics Abbreviated Journal (up) ELEC  
  Volume 12 Issue 18 Pages 3947  
  Keywords micro-expression spotting; sliding window; key frame extraction  
  Abstract Micro-expressions reveal underlying emotions and are widely applied in political psychology, lie detection, law enforcement and medical care. Micro-expression spotting aims to detect the temporal locations of facial expressions from video sequences and is a crucial task in micro-expression recognition. In this study, the problem of micro-expression spotting is formulated as micro-expression classification per frame. We propose an effective spotting model with sliding windows called the spatio-temporal spotting network. The method involves a sliding window detection mechanism, combines the spatial features from the local key frames and the global temporal features and performs micro-expression spotting. The experiments are conducted on the CAS(ME)2 database and the SAMM Long Videos database, and the results demonstrate that the proposed method outperforms the state-of-the-art method by 30.58% for the CAS(ME)2 and 23.98% for the SAMM Long Videos according to overall F-scores.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes ISE Approved no  
  Call Number Admin @ si @ FAH2023 Serial 3864  
Permanent link to this record
 

 
Author Ana Garcia Rodriguez; Yael Tudela; Henry Cordova; S. Carballal; I. Ordas; L. Moreira; E. Vaquero; O. Ortiz; L. Rivero; F. Javier Sanchez; Miriam Cuatrecasas; Maria Pellise; Jorge Bernal; Gloria Fernandez Esparrach edit  doi
openurl 
  Title First in Vivo Computer-Aided Diagnosis of Colorectal Polyps using White Light Endoscopy Type Journal Article
  Year 2022 Publication Endoscopy Abbreviated Journal (up) END  
  Volume 54 Issue Pages  
  Keywords  
  Abstract  
  Address 2022/04/14  
  Corporate Author Thesis  
  Publisher Georg Thieme Verlag KG Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes ISE Approved no  
  Call Number Admin @ si @ GTC2022a Serial 3746  
Permanent link to this record
 

 
Author O.F.Ahmad; Y.Mori; M.Misawa; S.Kudo; J.T.Anderson; Jorge Bernal edit  url
doi  openurl
  Title Establishing key research questions for the implementation of artificial intelligence in colonoscopy: a modified Delphi method Type Journal Article
  Year 2021 Publication Endoscopy Abbreviated Journal (up) END  
  Volume 53 Issue 9 Pages 893-901  
  Keywords  
  Abstract BACKGROUND : Artificial intelligence (AI) research in colonoscopy is progressing rapidly but widespread clinical implementation is not yet a reality. We aimed to identify the top implementation research priorities. METHODS : An established modified Delphi approach for research priority setting was used. Fifteen international experts, including endoscopists and translational computer scientists/engineers, from nine countries participated in an online survey over 9 months. Questions related to AI implementation in colonoscopy were generated as a long-list in the first round, and then scored in two subsequent rounds to identify the top 10 research questions. RESULTS : The top 10 ranked questions were categorized into five themes. Theme 1: clinical trial design/end points (4 questions), related to optimum trial designs for polyp detection and characterization, determining the optimal end points for evaluation of AI, and demonstrating impact on interval cancer rates. Theme 2: technological developments (3 questions), including improving detection of more challenging and advanced lesions, reduction of false-positive rates, and minimizing latency. Theme 3: clinical adoption/integration (1 question), concerning the effective combination of detection and characterization into one workflow. Theme 4: data access/annotation (1 question), concerning more efficient or automated data annotation methods to reduce the burden on human experts. Theme 5: regulatory approval (1 question), related to making regulatory approval processes more efficient. CONCLUSIONS : This is the first reported international research priority setting exercise for AI in colonoscopy. The study findings should be used as a framework to guide future research with key stakeholders to accelerate the clinical implementation of AI in endoscopy.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes ISE Approved no  
  Call Number Admin @ si @ AMM2021 Serial 3670  
Permanent link to this record
 

 
Author Ana Garcia Rodriguez; Yael Tudela; Henry Cordova; S. Carballal; I. Ordas; L. Moreira; E. Vaquero; O. Ortiz; L. Rivero; F. Javier Sanchez; Miriam Cuatrecasas; Maria Pellise; Jorge Bernal; Gloria Fernandez Esparrach edit  doi
openurl 
  Title In vivo computer-aided diagnosis of colorectal polyps using white light endoscopy Type Journal Article
  Year 2022 Publication Endoscopy International Open Abbreviated Journal (up) ENDIO  
  Volume 10 Issue 9 Pages E1201-E1207  
  Keywords  
  Abstract Background and study aims Artificial intelligence is currently able to accurately predict the histology of colorectal polyps. However, systems developed to date use complex optical technologies and have not been tested in vivo. The objective of this study was to evaluate the efficacy of a new deep learning-based optical diagnosis system, ATENEA, in a real clinical setting using only high-definition white light endoscopy (WLE) and to compare its performance with endoscopists. Methods ATENEA was prospectively tested in real life on consecutive polyps detected in colorectal cancer screening colonoscopies at Hospital Clínic. No images were discarded, and only WLE was used. The in vivo ATENEA's prediction (adenoma vs non-adenoma) was compared with the prediction of four staff endoscopists without specific training in optical diagnosis for the study purposes. Endoscopists were blind to the ATENEA output. Histology was the gold standard. Results Ninety polyps (median size: 5 mm, range: 2-25) from 31 patients were included of which 69 (76.7 %) were adenomas. ATENEA correctly predicted the histology in 63 of 69 (91.3 %, 95 % CI: 82 %-97 %) adenomas and 12 of 21 (57.1 %, 95 % CI: 34 %-78 %) non-adenomas while endoscopists made correct predictions in 52 of 69 (75.4 %, 95 % CI: 60 %-85 %) and 20 of 21 (95.2 %, 95 % CI: 76 %-100 %), respectively. The global accuracy was 83.3 % (95 % CI: 74%-90 %) and 80 % (95 % CI: 70 %-88 %) for ATENEA and endoscopists, respectively. Conclusion ATENEA can accurately be used for in vivo characterization of colorectal polyps, enabling the endoscopist to make direct decisions. ATENEA showed a global accuracy similar to that of endoscopists despite an unsatisfactory performance for non-adenomatous lesions.  
  Address 2022 Sep 14  
  Corporate Author Thesis  
  Publisher PMID Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes ISE; 600.157 Approved no  
  Call Number Admin @ si @ GTC2022b Serial 3752  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: