toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author David Rotger; Misael Rosales; Jaume Garcia; Oriol Pujol ; Josefina Mauri; Petia Radeva edit   pdf
openurl 
  Title Active Vessel: A New Multimedia Workstation for Intravascular Ultrasound and Angiography Fusion Type Journal Article
  Year 2003 Publication Computers in Cardiology Abbreviated Journal  
  Volume (up) 30 Issue Pages 65-68  
  Keywords  
  Abstract AcriveVessel is a new multimedia workstation which enables the visualization, acquisition and handling of both image modalities, on- and ofline. It enables DICOM v3.0 decompression and browsing, video acquisition,repmduction and storage for IntraVascular UltraSound (IVUS) and angiograms with their corresponding ECG,automatic catheter segmentation in angiography images (using fast marching algorithm). BSpline models definition for vessel layers on IVUS images sequence and an extensively validated tool to fuse information. This approach defines the correspondence of every IVUS image with its correspondent point in the angiogram and viceversa. The 3 0 reconstruction of the NUS catheterhessel enables real distance measurements as well as threedimensional visualization showing vessel tortuosity in the space.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM;MILAB;HuPBA Approved no  
  Call Number IAM @ iam @ RRG2003 Serial 1647  
Permanent link to this record
 

 
Author Aura Hernandez-Sabate; Debora Gil; Petia Radeva; E.N.Nofrerias edit   pdf
doi  openurl
  Title Anisotropic processing of image structures for adventitia detection in intravascular ultrasound images Type Conference Article
  Year 2004 Publication Proc. Computers in Cardiology Abbreviated Journal  
  Volume (up) 31 Issue Pages 229-232  
  Keywords  
  Abstract The adventitia layer appears as a weak edge in IVUS images with a non-uniform grey level, which difficulties its detection. In order to enhance edges, we apply an anisotropic filter that homogenizes the grey level along the image significant structures (ridges, valleys and edges). A standard edge detector applied to the filtered image yields a set of candidate points prone to be unconnected. The final model is obtained by interpolating the former line segments along the tangent direction to the level curves of the filtered image with an anisotropic contour closing technique based on functional extension principles  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Chicago (USA) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM; MILAB Approved no  
  Call Number IAM @ iam @ HGR2004 Serial 1555  
Permanent link to this record
 

 
Author Jaume Garcia; Joel Barajas; Francesc Carreras; Sandra Pujades; Petia Radeva edit   pdf
doi  isbn
openurl 
  Title An intuitive validation technique to compare local versus global tagged MRI analysis Type Conference Article
  Year 2005 Publication Computers In Cardiology Abbreviated Journal  
  Volume (up) 32 Issue Pages 29–32  
  Keywords  
  Abstract Myocardium appears as a uniform tissue that seen in convectional Magnetic Resonance Images (MRI) shows just the contractile part of its movement. MR Tagging is a unique imaging technique that prints a grid over the tissue which moves according to the underlying movement of the myocardium revealing the true deformation of the cardiac muscle. Optical flow techniques based on spectral information estimate tissue displacement by analyzing information encoded in the phase maps which can be obtained using, local (Gabor) and global (HARP) methods. In this paper we compare both in synthetic and real Tagged MR sequences. We conclude that local method is slightly more accurate than the global one. On the other hand, global method is more efficient as it is much faster and less parameters have to be taken into account  
  Address Lyon (France)  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 0-7803-9337-6 Medium  
  Area Expedition Conference  
  Notes IAM;MILAB Approved no  
  Call Number IAM @ iam @ GBC2005 Serial 639  
Permanent link to this record
 

 
Author Enric Marti; Jordi Regincos;Jaime Lopez-Krahe; Juan J.Villanueva edit  url
doi  openurl
  Title Hand line drawing interpretation as three-dimensional objects Type Journal Article
  Year 1993 Publication Signal Processing – Intelligent systems for signal and image understanding Abbreviated Journal  
  Volume (up) 32 Issue 1-2 Pages 91-110  
  Keywords Line drawing interpretation; line labelling; scene analysis; man-machine interaction; CAD input; line extraction  
  Abstract In this paper we present a technique to interpret hand line drawings as objects in a three-dimensional space. The object domain considered is based on planar surfaces with straight edges, concretely, on ansextension of Origami world to hidden lines. The line drawing represents the object under orthographic projection and it is sensed using a scanner. Our method is structured in two modules: feature extraction and feature interpretation. In the first one, image processing techniques are applied under certain tolerance margins to detect lines and junctions on the hand line drawing. Feature interpretation module is founded on line labelling techniques using a labelled junction dictionary. A labelling algorithm is here proposed. It uses relaxation techniques to reduce the number of incompatible labels with the junction dictionary so that the convergence of solutions can be accelerated. We formulate some labelling hypotheses tending to eliminate elements in two sets of labelled interpretations. That is, those which are compatible with the dictionary but do not correspond to three-dimensional objects and those which represent objects not very probable to be specified by means of a line drawing. New entities arise on the line drawing as a result of the extension of Origami world. These are defined to enunciate the assumptions of our method as well as to clarify the algorithms proposed. This technique is framed in a project aimed to implement a system to create 3D objects to improve man-machine interaction in CAD systems.  
  Address  
  Corporate Author Thesis  
  Publisher Elsevier North-Holland, Inc. Place of Publication Amsterdam, The Netherlands, The Netherlands Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0165-1684 ISBN Medium  
  Area Expedition Conference  
  Notes IAM;ISE; Approved no  
  Call Number IAM @ iam @ MRL1993 Serial 1611  
Permanent link to this record
 

 
Author Aura Hernandez-Sabate; Debora Gil; Josefina Mauri; Petia Radeva edit   pdf
openurl 
  Title Reducing cardiac motion in IVUS sequences Type Conference Article
  Year 2006 Publication Proceeding of Computers in Cardiology Abbreviated Journal  
  Volume (up) 33 Issue Pages 685-688  
  Keywords  
  Abstract Cardiac vessel displacement is a main artifact in IVUS sequences. It hinders visualization of the main structures in an appropriate orientation and alignment and affects extracting vessel measurements. In this paper, we present a novel approach for image sequence alignment based on spectral analysis, which removes rigid dynamics, preserving at the same time the vessel geometry. First, we suppress the translation by taking, for each frame, the center of mass of the image as origin of coordinates. In polar coordinates with such point as origin, the rotation appears as a horizontal displacement. The translation induces a phase shift in the Fourier coefficients of two consecutive polar images. We estimate the phase by adjusting a regression plane to the phases of the principal frequencies. Experiments show that the presented strategy suppress cardiac motion regardless of the acquisition device. 1.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM; MILAB Approved no  
  Call Number IAM @ iam @ HGM2006a Serial 1554  
Permanent link to this record
 

 
Author Jaume Garcia; Debora Gil; A.Bajo; M.J.Ledesma-Carbayo; C.SantaMarta edit   pdf
doi  openurl
  Title Influence of the temporal resolution on the quantification of displacement fields in cardiac magnetic resonance tagged images Type Conference Article
  Year 2008 Publication Proc. Computers in Cardiology Abbreviated Journal  
  Volume (up) 35 Issue Pages 785-788  
  Keywords  
  Abstract It is difficult to acquire tagged cardiac MR images with a high temporal and spatial resolution using clinical MR scanners. However, if such images are used for quantifying scores based on motion, it is essential a resolution as high as possible. This paper explores the influence of the temporal resolution of a tagged series on the quantification of myocardial dynamic parameters. To such purpose we have designed a SPAMM (Spatial Modulation of Magnetization) sequence allowing acquisition of sequences at simple and double temporal resolution. Sequences are processed to compute myocardial motion by an automatic technique based on the tracking of the harmonic phase of tagged images (the Harmonic Phase Flow, HPF). The results have been compared to manual tracking of myocardial tags. The error in displacement fields for double resolution sequences reduces 17%.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor Alan Murray  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM Approved no  
  Call Number IAM @ iam @ GGB2008 Serial 1508  
Permanent link to this record
 

 
Author Debora Gil; Sergio Vera; Agnes Borras; Albert Andaluz; Miguel Angel Gonzalez Ballester edit   pdf
doi  openurl
  Title Anatomical Medial Surfaces with Efficient Resolution of Branches Singularities Type Journal Article
  Year 2017 Publication Medical Image Analysis Abbreviated Journal MIA  
  Volume (up) 35 Issue Pages 390-402  
  Keywords Medial Representations; Shape Recognition; Medial Branching Stability ; Singular Points  
  Abstract Medial surfaces are powerful tools for shape description, but their use has been limited due to the sensibility existing methods to branching artifacts. Medial branching artifacts are associated to perturbations of the object boundary rather than to geometric features. Such instability is a main obstacle for a con dent application in shape recognition and description. Medial branches correspond to singularities of the medial surface and, thus, they are problematic for existing morphological and energy-based algorithms. In this paper, we use algebraic geometry concepts in an energy-based approach to compute a medial surface presenting a stable branching topology. We also present an ecient GPU-CPU implementation using standard image processing tools. We show the method computational eciency and quality on a custom made synthetic database. Finally, we present some results on a medical imaging application for localization of abdominal pathologies.  
  Address  
  Corporate Author Thesis  
  Publisher Elsevier B.V. Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM; 600.060; 600.096; 600.075; 600.145 Approved no  
  Call Number Admin @ si @ GVB2017 Serial 2775  
Permanent link to this record
 

 
Author Aura Hernandez-Sabate; Monica Mitiko; Sergio Shiguemi; Debora Gil edit   pdf
url  isbn
openurl 
  Title A validation protocol for assessing cardiac phase retrieval in IntraVascular UltraSound Type Conference Article
  Year 2010 Publication Computing in Cardiology Abbreviated Journal  
  Volume (up) 37 Issue Pages 899-902  
  Keywords  
  Abstract A good reliable approach to cardiac triggering is of utmost importance in obtaining accurate quantitative results of atherosclerotic plaque burden from the analysis of IntraVascular UltraSound. Although, in the last years, there has been an increase in research of methods for retrospective gating, there is no general consensus in a validation protocol. Many methods are based on quality assessment of longitudinal cuts appearance and those reporting quantitative numbers do not follow a standard protocol. Such heterogeneity in validation protocols makes faithful comparison across methods a difficult task. We propose a validation protocol based on the variability of the retrieved cardiac phase and explore the capability of several quality measures for quantifying such variability. An ideal detector, suitable for its application in clinical practice, should produce stable phases. That is, it should always sample the same cardiac cycle fraction. In this context, one should measure the variability (variance) of a candidate sampling with respect a ground truth (reference) sampling, since the variance would indicate how spread we are aiming a target. In order to quantify the deviation between the sampling and the ground truth, we have considered two quality scores reported in the literature: signed distance to the closest reference sample and distance to the right of each reference sample. We have also considered the residuals of the regression line of reference against candidate sampling. The performance of the measures has been explored on a set of synthetic samplings covering different cardiac cycle fractions and variabilities. From our simulations, we conclude that the metrics related to distances are sensitive to the shift considered while the residuals are robust against fraction and variabilities as far as one can establish a pair-wise correspondence between candidate and reference. We will further investigate the impact of false positive and negative detections in experimental data.  
  Address  
  Corporate Author Thesis  
  Publisher IEEE Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0276-6547 ISBN 978-1-4244-7318-2 Medium  
  Area Expedition Conference CINC  
  Notes IAM; Approved no  
  Call Number IAM @ iam @ HSM2010 Serial 1551  
Permanent link to this record
 

 
Author Gloria Fernandez Esparrach; Jorge Bernal; Cristina Rodriguez de Miguel; Debora Gil; Fernando Vilariño; Henry Cordova; Cristina Sanchez Montes; Isis Ara edit  openurl
  Title Utilidad de la visión por computador para la localización de pólipos pequeños y planos Type Conference Article
  Year 2016 Publication XIX Reunión Nacional de la Asociación Española de Gastroenterología, Gastroenterology Hepatology Abbreviated Journal  
  Volume (up) 39 Issue 2 Pages 94  
  Keywords  
  Abstract  
  Address Madrid (Spain)  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference AEGASTRO  
  Notes MV; IAM; 600.097;SIAI Approved no  
  Call Number Admin @ si @FBR2016 Serial 2779  
Permanent link to this record
 

 
Author Jorge Bernal; F. Javier Sanchez; Gloria Fernandez Esparrach; Debora Gil; Cristina Rodriguez de Miguel; Fernando Vilariño edit   pdf
doi  openurl
  Title WM-DOVA Maps for Accurate Polyp Highlighting in Colonoscopy: Validation vs. Saliency Maps from Physicians Type Journal Article
  Year 2015 Publication Computerized Medical Imaging and Graphics Abbreviated Journal CMIG  
  Volume (up) 43 Issue Pages 99-111  
  Keywords Polyp localization; Energy Maps; Colonoscopy; Saliency; Valley detection  
  Abstract We introduce in this paper a novel polyp localization method for colonoscopy videos. Our method is based on a model of appearance for polyps which defines polyp boundaries in terms of valley information. We propose the integration of valley information in a robust way fostering complete, concave and continuous boundaries typically associated to polyps. This integration is done by using a window of radial sectors which accumulate valley information to create WMDOVA1 energy maps related with the likelihood of polyp presence. We perform a double validation of our maps, which include the introduction of two new databases, including the first, up to our knowledge, fully annotated database with clinical metadata associated. First we assess that the highest value corresponds with the location of the polyp in the image. Second, we show that WM-DOVA energy maps can be comparable with saliency maps obtained from physicians' fixations obtained via an eye-tracker. Finally, we prove that our method outperforms state-of-the-art computational saliency results. Our method shows good performance, particularly for small polyps which are reported to be the main sources of polyp miss-rate, which indicates the potential applicability of our method in clinical practice.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0895-6111 ISBN Medium  
  Area Expedition Conference  
  Notes MV; IAM; 600.047; 600.060; 600.075;SIAI Approved no  
  Call Number Admin @ si @ BSF2015 Serial 2609  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: