Andrew Nolan, Daniel Serrano, Aura Hernandez-Sabate, Daniel Ponsa, & Antonio Lopez. (2013). "Obstacle mapping module for quadrotors on outdoor Search and Rescue operations " In International Micro Air Vehicle Conference and Flight Competition.
Abstract: Obstacle avoidance remains a challenging task for Micro Aerial Vehicles (MAV), due to their limited payload capacity to carry advanced sensors. Unlike larger vehicles, MAV can only carry light weight sensors, for instance a camera, which is our main assumption in this work. We explore passive monocular depth estimation and propose a novel method Position Aided Depth Estimation
(PADE). We analyse PADE performance and compare it against the extensively used Time To Collision (TTC). We evaluate the accuracy, robustness to noise and speed of three Optical Flow (OF) techniques, combined with both depth estimation methods. Our results show PADE is more accurate than TTC at depths between 0-12 meters and is less sensitive to noise. Our findings highlight the potential application of PADE for MAV to perform safe autonomous navigation in
unknown and unstructured environments.
Keywords: UAV
|
|
|
Patricia Marquez, Debora Gil, & Aura Hernandez-Sabate. (2012). "Error Analysis for Lucas-Kanade Based Schemes " In 9th International Conference on Image Analysis and Recognition (Vol. 7324, pp. 184–191). Lecture Notes in Computer Science. Springer-Verlag Berlin Heidelberg.
Abstract: Optical flow is a valuable tool for motion analysis in medical imaging sequences. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in medical sequences. This paper presents an error analysis of Lucas-Kanade schemes in terms of intrinsic design errors and numerical stability of the algorithm. Our analysis provides a confidence measure that is naturally correlated to the accuracy of the flow field. Our experiments show the higher predictive value of our confidence measure compared to existing measures.
Keywords: Optical flow, Confidence measure, Lucas-Kanade, Cardiac Magnetic Resonance
|
|
|
Patricia Marquez, Debora Gil, & Aura Hernandez-Sabate. (2013). "Evaluation of the Capabilities of Confidence Measures for Assessing Optical Flow Quality " In ICCV Workshop on Computer Vision in Vehicle Technology: From Earth to Mars (pp. 624–631).
Abstract: Assessing Optical Flow (OF) quality is essential for its further use in reliable decision support systems. The absence of ground truth in such situations leads to the computation of OF Confidence Measures (CM) obtained from either input or output data. A fair comparison across the capabilities of the different CM for bounding OF error is required in order to choose the best OF-CM pair for discarding points where OF computation is not reliable. This paper presents a statistical probabilistic framework for assessing the quality of a given CM. Our quality measure is given in terms of the percentage of pixels whose OF error bound can not be determined by CM values. We also provide statistical tools for the computation of CM values that ensures a given accuracy of the flow field.
|
|
|
Patricia Marquez, Debora Gil, & Aura Hernandez-Sabate. (2012). "A Complete Confidence Framework for Optical Flow " In Rita Cucchiara V. M. Andrea Fusiello (Ed.), 12th European Conference on Computer Vision – Workshops and Demonstrations (Vol. 7584, pp. 124–133). Florence, Italy, October 7-13, 2012: Springer-Verlag.
Abstract: Medial representations are powerful tools for describing and parameterizing the volumetric shape of anatomical structures. Existing methods show excellent results when applied to 2D objects, but their quality drops across dimensions. This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial manifolds that avoid degenerated medial axis segments; second, we introduce an energy based method which performs independently of the dimension. We evaluate quantitatively the performance of our method with respect to existing approaches, by applying them to synthetic shapes of known medial geometry. Finally, we show results on shape representation of multiple abdominal organs, exploring the use of medial manifolds for the representation of multi-organ relations.
Keywords: Optical flow, confidence measures, sparsification plots, error prediction plots
|
|
|
Patricia Marquez, Debora Gil, Aura Hernandez-Sabate, & Daniel Kondermann. (2013). "When Is A Confidence Measure Good Enough? " In 9th International Conference on Computer Vision Systems (Vol. 7963, pp. 344–353). Springer Link.
Abstract: Confidence estimation has recently become a hot topic in image processing and computer vision.Yet, several definitions exist of the term “confidence” which are sometimes used interchangeably. This is a position paper, in which we aim to give an overview on existing definitions,
thereby clarifying the meaning of the used terms to facilitate further research in this field. Based on these clarifications, we develop a theory to compare confidence measures with respect to their quality.
Keywords: Optical flow, confidence measure, performance evaluation
|
|
|
Patricia Marquez, Debora Gil, R.Mester, & Aura Hernandez-Sabate. (2014). "Local Analysis of Confidence Measures for Optical Flow Quality Evaluation " In 9th International Conference on Computer Vision Theory and Applications (Vol. 3, pp. 450–457).
Abstract: Optical Flow (OF) techniques facing the complexity of real sequences have been developed in the last years. Even using the most appropriate technique for our specific problem, at some points the output flow might fail to achieve the minimum error required for the system. Confidence measures computed from either input data or OF output should discard those points where OF is not accurate enough for its further use. It follows that evaluating the capabilities of a confidence measure for bounding OF error is as important as the definition
itself. In this paper we analyze different confidence measures and point out their advantages and limitations for their use in real world settings. We also explore the agreement with current tools for their evaluation of confidence measures performance.
Keywords: Optical Flow; Confidence Measure; Performance Evaluation.
|
|
|
Enric Marti, Antoni Gurgui, Debora Gil, Aura Hernandez-Sabate, Jaume Rocarias, & Ferran Poveda. (2014). "ABP on line: Seguimiento, estregas y evaluación en aprendizaje basado en proyectos ".
|
|
|
Patricia Marquez, H. Kause, A. Fuster, Aura Hernandez-Sabate, L. Florack, Debora Gil, et al. (2014). "Factors Affecting Optical Flow Performance in Tagging Magnetic Resonance Imaging " In 17th International Conference on Medical Image Computing and Computer Assisted Intervention (Vol. 8896, pp. 231–238). Springer International Publishing.
Abstract: Changes in cardiac deformation patterns are correlated with cardiac pathologies. Deformation can be extracted from tagging Magnetic Resonance Imaging (tMRI) using Optical Flow (OF) techniques. For applications of OF in a clinical setting it is important to assess to what extent the performance of a particular OF method is stable across dierent clinical acquisition artifacts. This paper presents a statistical validation framework, based on ANOVA, to assess the motion and appearance factors that have the largest in uence on OF accuracy drop.
In order to validate this framework, we created a database of simulated tMRI data including the most common artifacts of MRI and test three dierent OF methods, including HARP.
Keywords: Optical flow; Performance Evaluation; Synthetic Database; ANOVA; Tagging Magnetic Resonance Imaging
|
|
|
Enric Marti, J.Roncaries, Debora Gil, Aura Hernandez-Sabate, Antoni Gurgui, & Ferran Poveda. (2015). "PBL On Line: A proposal for the organization, part-time monitoring and assessment of PBL group activities " . Journal of Technology and Science Education, 5(2), 87–96.
|
|
|
Hanne Kause, Patricia Marquez, Andrea Fuster, Aura Hernandez-Sabate, Luc Florack, Debora Gil, et al. (2015)." Quality Assessment of Optical Flow in Tagging MRI" In 5th Dutch Bio-Medical Engineering Conference BME2015.
|
|