G.Estape, & Enric Marti. (2008)." L’ús d’aplicacions de visualització 3D com a eina d’aprenenetatge en activitats formatives dirigides i autònomes: el cas del programa Bluestar" .
|
|
|
Cristina Cañero, Petia Radeva, Oriol Pujol, Ricardo Toledo, Debora Gil, J. Saludes, et al. (1999). "Three-dimensional reconstruction and quantification of the coronary tree using intravascular ultrasound images " In Proceedings of International Conference on Computer in Cardiology (CIC´99).
Abstract: In this paper we propose a new Computer Vision technique to reconstruct the vascular wall in space using a deformable model-based technique and compounding methods, based in biplane angiography and intravascular ultrasound data jicsion. It is also proposed a generalpurpose three-dimensional guided interpolation method. The three dimensional centerline of the vessel is reconstructed from geometrically corrected biplane angiographies using automatic segmentation methods and snakes. The IVUS image planes are located in the threedimensional space and correctly oriented. A led interpolation method based in B-SurJaces and snakes isused to fill the gaps among image planes
|
|
|
Cristina Cañero, Petia Radeva, Oriol Pujol, Ricardo Toledo, Debora Gil, J. Saludes, et al. (1999). "Optimal Stent Implantation: Three-dimensional Evaluation of the Mutual Position of Stent and Vessel via Intracoronary Ecography " In Proceedings of International Conference on Computer in Cardiology (CIC´99).
Abstract: We present a new automatic technique to visualize and quantify the mutual position between the stent and the vessel wall by considering their three-dimensional reconstruction. Two deformable generalized cylinders adapt to the image features in all IVUS planes corresponding to the vessel wall and the stent in order to reconstruct the boundaries of the stent and the vessel in space. The image features that characterize the stent and the vessel wall are determined in terms of edge and ridge image detectors taking into account the gray level of the image pixels. We show that the 30 reconstruction by deformable cylinders is accurate and robust due to the spatial data coherence in the considered volumetric IVUS image. The main clinic utility of the stent and vessel reconstruction by deformable’ cylinders consists of its possibility to visualize and to assess the optimal stent introduction.
|
|
|
Francesc Carreras, Jaume Garcia, Debora Gil, Sandra Pujadas, Chi ho Lion, R.Suarez-Arias, et al. (2012). "Left ventricular torsion and longitudinal shortening: two fundamental components of myocardial mechanics assessed by tagged cine-MRI in normal subjects " . International Journal of Cardiovascular Imaging, 28(2), 273–284.
Abstract: Cardiac magnetic resonance imaging (Cardiac MRI) has become a gold standard diagnostic technique for the assessment of cardiac mechanics, allowing the non-invasive calculation of left ventric- ular long axis longitudinal shortening (LVLS) and absolute myocardial torsion (AMT) between basal and apical left ventricular slices, a movement directly related to the helicoidal anatomic disposition of the myocardial fibers. The aim of this study is to determine AMT and LVLS behaviour and normal values from a group of healthy subjects. A group of 21 healthy volunteers (15 males) (age: 23–55 y.o., mean:30.7 ± 7.5) were prospectively included in an obser- vational study by Cardiac MRI. Left ventricular rotation (degrees) was calculated by custom-made software (Harmonic Phase Flow) in consecutive LV short axis planes tagged cine-MRI sequences. AMT was determined from the difference between basal and apical planes LV rotations. LVLS (%) was determined from the LV longitudinal and horizontal axis cine-MRI images. All the 21 cases studied were interpretable, although in three cases the value of the LV apical rotation could not be determined. The mean rotation of the basal and apical planes at end-systole were -3.71° ± 0.84° and 6.73° ± 1.69° (n:18) respectively, resulting in a LV mean AMT of 10.48° ± 1.63° (n:18). End-systolic mean LVLS was 19.07 ± 2.71%. Cardiac MRI allows for the calculation of AMT and LVLS, fundamental functional components of the ventricular twist mechanics conditioned, in turn, by the anatomical helical layout of the myocardial fibers. These values provide complementary information about systolic ventricular function in relation to the traditional parameters used in daily practice.
Keywords: Magnetic resonance imaging (MRI); Tagging MRI; Cardiac mechanics; Ventricular torsion
|
|
|
Joel Barajas, Jaume Garcia, Karla Lizbeth Caballero, Francesc Carreras, Sandra Pujades, & Petia Radeva. (2006). "Correction of Misalignment Artifacts Among 2-D Cardiac MR Images in 3-D Space " In 1st International Wokshop on Computer Vision for Intravascular and Intracardiac Imaging (CVII’06) (Vol. 3217, pp. 114–121). Copenhagen (Denmark).
Abstract: Cardiac Magnetic Resonance images offer the opportunity to study the heart in detail. One of the main issues in its modelling is to create an accurate 3-D reconstruction of the left ventricle from 2-D views. A first step to achieve this goal is the correct registration among the different image planes due to patient movements. In this article, we present an accurate method to correct displacement artifacts using the Normalized Mutual Information. Here, the image views are treated as planes in order to diminish the approximation error caused by the association of a certain thickness, and moved simultaneously to avoid any kind of bias in the alignment process. This method has been validated using real and syntectic plane displacements, yielding promising results.
|
|
|
J.L.Bruguera, R.Casado, M.Martinez, I.Corral, Enric Marti, & L.A.Branda. (2009)." El apoyo institucional como elemento favorecedor de la coordinación docente: experiencias en diferentes universidades" .
|
|
|
Albert Andaluz. (2012). "Harmonic Phase Flow: User's guide ". Barcelona: CVC.
Abstract: HPF is a plugin for the computation of clinical scores under Osirix.
This manual provides a basic guide for experienced clinical staff. Chapter 1 provides the theoretical background in which this plugin is based.
Next, in chapter 2 we provide basic instructions for installing and uninstalling this plugin. chapter 3we shows a step-by-step scenario to compute clinical scores from tagged-MRI images with HPF. Finally, in chapter 4 we provide a quick guide for plugin developers
|
|
|
Albert Andaluz. (2009). "LV Contour Segmentation in TMR images using Semantic Description of Tissue and Prior Knowledge Correction " (Vol. 142). Master's thesis, , Bellaterra 08193, Barcelona, Spain.
Abstract: The Diagnosis of Left Ventricle (LV) pathologies is related to regional wall motion analysis. Health indicator scores such as the rotation and the torsion are useful for the diagnose of the Left Ventricle (LV) function. However, this requires proper identification of LV segments. On one hand, manual segmentation is robust, but it is slow and requires medical expertise. On the other hand, the tag pattern in Tagged Magnetic Resonance (TMR) sequences is a problem for the automatic segmentation of the LV boundaries. Consequently, we propose a method based in the classical formulation of parametric Snakes, combined with Active Shape models. Our semantic definition of the LV is tagged tissue that experiences motion in the systolic cycle. This defines two energy potentials for the Snake convergence. Additionally, the mean shape corrects excessive deviation from the anatomical shape. We have validated our approach in 15 healthy volunteers and two short axis cuts. In this way, we have compared the automatic segmentations to manual shapes outlined by medical experts. Also, we have explored the accuracy of clinical scores computed using automatic contours. The results show minor divergence in the approximation and the manual segmentations as well as robust computation of clinical scores in all cases. From this we conclude that the proposed method is a promising support tool for clinical analysis.
Keywords: Active Contour Models; Snakes; Active Shape Models; Deformable Templates; Left Ventricle Segmentation; Generalized Orthogonal Procrustes Analysis; Harmonic Phase Flow; Principal Component Analysis; Tagged Magnetic Resonance
|
|
|
Eric Amiel. (2005). "Visualisation de vaisseaux sanguins " (Enric Marti, Ed.). Bachelor's thesis, Université Paul Sabatier Toulouse III, Toulouse.
|
|
|
Albert Andaluz, Francesc Carreras, Cristina Santa Marta, & Debora Gil. (2012). "Myocardial torsion estimation with Tagged-MRI in the OsiriX platform " In Wiro Niessen(Erasmus MC) and Marc Modat(UCL) (Ed.), ISBI Workshop on Open Source Medical Image Analysis software. IEEE.
Abstract: Myocardial torsion (MT) plays a crucial role in the assessment of the functionality of the
left ventricle. For this purpose, the IAM group at the CVC has developed the Harmonic Phase Flow (HPF) plugin for the Osirix DICOM platform . We have validated its funcionalty on sequences acquired using different protocols and including healthy and pathological cases. Results show similar torsion trends for SPAMM acquisitions, with pathological cases introducing expected deviations from the ground truth. Finally, we provide the plugin free of charge at http://iam.cvc.uab.es
|
|