Luca Ginanni Corradini, Simone Balocco, Luciano Maresca, Silvio Vitale, & Matteo Stefanini. (2023). Anatomical Modifications After Stent Implantation: A Comparative Analysis Between CGuard, Wallstent, and Roadsaver Carotid Stents. Journal of Endovascular Therapy, 30(1), 18–24.
Abstract: Abstract
Purpose:
Carotid revascularization can be associated with modifications of the vascular geometry, which may lead to complications. The changes on the vessel angulation before and after a carotid WallStent (WS) implantation are compared against 2 new dual-layer devices, CGuard (CG) and RoadSaver (RS).
Materials and Methods:
The study prospectively recruited 217 consecutive patients (112 GC, 73 WS, and 32 RS, respectively). Angiography projections were explored and the one having a higher arterial angle was selected as a basal view. After stent implantation, a stent control angiography was performed selecting the projection having the maximal angle. The same procedure is followed in all the 3 stent types to guarantee comparable conditions. The angulation changes on the stented segments were quantified from both angiographies. The statistical analysis quantitatively compared the pre-and post-angles for the 3 stent types. The results are qualitatively illustrated using boxplots. Finally, the relation between pre- and post-angles measurements is analyzed using linear regression.
Results:
For CG, no statistical difference in the axial vessel geometry between the basal and postprocedural angles was found. For WS and RS, statistical difference was found between pre- and post-angles. The regression analysis shows that CG induces lower changes from the original curvature with respect to WS and RS.
Conclusion:
Based on our results, CG determines minor changes over the basal morphology than WS and RS stents. Hence, CG respects better the native vessel anatomy than the other stents.
Level of Evidence: Level 4, Case Series.
Keywords: Ginanni Corradini L, Balocco S, Maresca L, Vitale S, Stefanini M.
|
Sergio Vera, Debora Gil, & Miguel Angel Gonzalez Ballester. (2014). Anatomical parameterization for volumetric meshing of the liver. In SPIE – Medical Imaging (Vol. 9036).
Abstract: A coordinate system describing the interior of organs is a powerful tool for a systematic localization of injured tissue. If the same coordinate values are assigned to specific anatomical landmarks, the coordinate system allows integration of data across different medical image modalities. Harmonic mappings have been used to produce parametric coordinate systems over the surface of anatomical shapes, given their flexibility to set values
at specific locations through boundary conditions. However, most of the existing implementations in medical imaging restrict to either anatomical surfaces, or the depth coordinate with boundary conditions is given at sites
of limited geometric diversity. In this paper we present a method for anatomical volumetric parameterization that extends current harmonic parameterizations to the interior anatomy using information provided by the
volume medial surface. We have applied the methodology to define a common reference system for the liver shape and functional anatomy. This reference system sets a solid base for creating anatomical models of the patient’s liver, and allows comparing livers from several patients in a common framework of reference.
Keywords: Coordinate System; Anatomy Modeling; Parameterization
|
Mireia Sole, Joan Blanco, Debora Gil, G. Fonseka, Richard Frodsham, Oliver Valero, et al. (2017). Análisis 3d de la territorialidad cromosómica en células espermatogénicas: explorando la infertilidad desde un nuevo prisma. ASEBIR - Revista Asociación para el Estudio de la Biología de la Reproducción, 105.
|
Sergio Escalera, Josep Moya, Laura Igual, Veronica Violant, & Maria Teresa Anguera. (2012). Análisis Comportamental Automatizado de TDAH: la Influencia de la Variable Motivación. In IPSI – Cosmocaixa, Jornadas "Empremtes del present, efectes en la psicoanàlisi, la cultura i la societat.
|
Enric Marti. (1996). Análisis de elementos gráficos en documentos. CVC UAB: Computer Vision Centre.
Abstract: En este texto se presenta un estudio sobre las t’ecnicas y aplicaciones de an’alisis de documentos, y más concretamente abordando la problem’atica del an’alisis de de entidades gr’aficas. El ’area de an’alisis de documentos tiene como objetivo la interpretaci’on de documentos impresos sobre papel por m’etodos computacionales, para obtener una descripci’on con un alto nivel de abstracci’on, que permita su posterior tratamiento y archivo por m’etodos inform’aticos. Este objetivo, junto a los trabajos realizados hasta el momento, le otorgan a esta ’area un amplio ’ambito de aplicaciones para la manipulaci’on y archivo de documentos sobre papel, que puede llegar a significar un salto cualitativo importante (del papel al disco ’optico) en el uso de soportes de informaci’on, debido a las importantes prestaciones de acceso y capacidad de archivo que suponen los medios inform’aticos. Generalmente los documentos son introducidos en los sistemas de an’alisis de documentos mediante scanner, obt...
|
Victor Ponce, Mario Gorga, Xavier Baro, Petia Radeva, & Sergio Escalera. (2011). Análisis de la expresión oral y gestual en proyectos fin de carrera vía un sistema de visión artificial. ReVisión, 4(1).
Abstract: La comunicación y expresión oral es una competencia de especial relevancia en el EEES. No obstante, en muchas enseñanzas superiores la puesta en práctica de esta competencia ha sido relegada principalmente a la presentación de proyectos fin de carrera. Dentro de un proyecto de innovación docente, se ha desarrollado una herramienta informática para la extracción de información objetiva para el análisis de la expresión oral y gestual de los alumnos. El objetivo es dar un “feedback” a los estudiantes que les permita mejorar la calidad de sus presentaciones. El prototipo inicial que se presenta en este trabajo permite extraer de forma automática información audiovisual y analizarla mediante técnicas de aprendizaje. El sistema ha sido aplicado a 15 proyectos fin de carrera y 15 exposiciones dentro de una asignatura de cuarto curso. Los resultados obtenidos muestran la viabilidad del sistema para sugerir factores que ayuden tanto en el éxito de la comunicación así como en los criterios de evaluación.
|
Lluis Pere de las Heras, & Gemma Sanchez. (2011). And-Or Graph Grammar for Architectural Floorplan Representation, Learning and Recognition. A Semantic, Structural and Hierarchical Model. In 5th Iberian Conference on Pattern Recognition and Image Analysis (Vol. 6669, pp. 17–24).
Abstract: This paper presents a syntactic model for architectural floor plan interpretation. A stochastic image grammar over an And-Or graph is inferred to represent the hierarchical, structural and semantic relations between elements of all possible floor plans. This grammar is augmented with three different probabilistic models, learnt from a training set, to account the frequency of that relations. Then, a Bottom-Up/Top-Down parser with a pruning strategy has been used for floor plan recognition. For a given input, the parser generates the most probable parse graph for that document. This graph not only contains the structural and semantic relations of its elements, but also its hierarchical composition, that allows to interpret the floor plan at different levels of abstraction.
|
Joel Barajas, Jaume Garcia, Francesc Carreras, Sandra Pujades, & Petia Radeva. (2005). Angle Images Using Gabor Filters in Cardiac Tagged MRI. In Proceeding of the 2005 conference on Artificial Intelligence Research and Development (pp. 107–114). Amsterdam, The Netherlands: IOS Press.
Abstract: Tagged Magnetic Resonance Imaging (MRI) is a non-invasive technique used to examine cardiac deformation in vivo. An Angle Image is a representation of a Tagged MRI which recovers the relative position of the tissue respect to the distorted tags. Thus cardiac deformation can be estimated. This paper describes a new approach to generate Angle Images using a bank of Gabor filters in short axis cardiac Tagged MRI. Our method improves the Angle Images obtained by global techniques, like HARP, with a local frequency analysis. We propose to use the phase response of a combination of a Gabor filters bank, and use it to find a more precise deformation of the left ventricle. We demonstrate the accuracy of our method over HARP by several experimental results.
Keywords: Angle Images, Gabor Filters, Harp, Tagged Mri
|
A.F. Sole, S. Ngan, G. Sapiro, X. Hu, & Antonio Lopez. (2001). Anisotropic 2-D and 3-D Averaging of fMRI Signals. IEEE Transactions on Medical Imaging, 20(2): 86–93 (IF: 3.142), .
|
Debora Gil, Petia Radeva, & Fernando Vilariño. (2003). Anisotropic Contour Completion. In Proceedings of the IEEE International Conference on Image Processing. Barcelona, Spain.
Abstract: In this paper we introduce a novel application of the diffusion tensor for anisotropic image processing. The Anisotropic Contour Completion (ACC) we suggest consists in extending the characteristic function of the open curve by means of a degenerated diffusion tensor that prevents any diffusion in the normal direction. We show that ACC is equivalent to a dilation with a continuous elliptic structural element that takes into account the local orientation of the contours to be closed. Experiments on contours extracted from real images show that ACC produces shapes able to adapt to any curve in an active contour framework. 1.
|
Panagiota Spyridonos, Fernando Vilariño, Jordi Vitria, Fernando Azpiroz, & Petia Radeva. (2006). Anisotropic Feature Extraction from Endoluminal Images for Detection of Intestinal Contractions. In and J. Sporring M. N. R. Larsen (Ed.), 9th International Conference on Medical Image Computing and Computer–Assisted Intervention (Vol. 4191, 161–168). LNCS. Berlin Heidelberg: Springer Verlag.
Abstract: Wireless endoscopy is a very recent and at the same time unique technique allowing to visualize and study the occurrence of con- tractions and to analyze the intestine motility. Feature extraction is es- sential for getting efficient patterns to detect contractions in wireless video endoscopy of small intestine. We propose a novel method based on anisotropic image filtering and efficient statistical classification of con- traction features. In particular, we apply the image gradient tensor for mining informative skeletons from the original image and a sequence of descriptors for capturing the characteristic pattern of contractions. Fea- tures extracted from the endoluminal images were evaluated in terms of their discriminatory ability in correct classifying images as either belong- ing to contractions or not. Classification was performed by means of a support vector machine classifier with a radial basis function kernel. Our classification rates gave sensitivity of the order of 90.84% and specificity of the order of 94.43% respectively. These preliminary results highlight the high efficiency of the selected descriptors and support the feasibility of the proposed method in assisting the automatic detection and analysis of contractions.
|
Aura Hernandez-Sabate, Debora Gil, Petia Radeva, & E.N.Nofrerias. (2004). Anisotropic processing of image structures for adventitia detection in intravascular ultrasound images. In Proc. Computers in Cardiology (Vol. 31, pp. 229–232). Chicago (USA).
Abstract: The adventitia layer appears as a weak edge in IVUS images with a non-uniform grey level, which difficulties its detection. In order to enhance edges, we apply an anisotropic filter that homogenizes the grey level along the image significant structures (ridges, valleys and edges). A standard edge detector applied to the filtered image yields a set of candidate points prone to be unconnected. The final model is obtained by interpolating the former line segments along the tangent direction to the level curves of the filtered image with an anisotropic contour closing technique based on functional extension principles
|
Enric Marti. (2008). Aplicació de la metodología d’Aprenentatge basat en Proyectes en l’assignatura de Gràfics per Computador d’enginyeria Informàtica. Balanç de Quatre anys d’experiència (Vol. 6).
|
Joan Serrat. (1995). Aplicacion del analisis de imagenes en radiologia..
|
C. Padres. (2000). Aplicaciones al modelo de formas activas para un entorno aumentado.
|