Partha Pratim Roy, & Josep Llados. (2008). Multi-Oriented Character Recognition from Graphical Documents. In 2nd International Conference on Cognition and Recognition (30–35).
|
Antonio Lopez, J. Hilgenstock, A. Busse, Ramon Baldrich, Felipe Lumbreras, & Joan Serrat. (2008). Temporal Coherence Analysis for Intelligent Headlight Control.
Keywords: Intelligent Headlights
|
David Masip, Agata Lapedriza, & Jordi Vitria. (2008). Multitask Learning: An Application to Incremental Face Recognition. In 3rd International Conference on Computer Vision Theory and Applications (Vol. 1, 585–590).
|
Agata Lapedriza, David Masip, & Jordi Vitria. (2008). Subject Recognition Using a New Approach for Feature Extraction. In 3rd International Conference on Computer Vision Theory and Applications (Vol. 2, 61–66).
|
Agnes Borras, & Josep Llados. (2008). A Multi-Scale Layout Descriptor Based on Delaunay Triangulation for Image Retrieval. In 3rd International Conference on Computer Vision Theory and Applications VISAPP (2) 2008 (Vol. 2, pp. 139–144).
|
Sergio Escalera, Oriol Pujol, & Petia Radeva. (2008). Loss-Weighted Decoding for Error-Correcting Output Coding. In 3rd International Conference on Computer Vision Theory and Applications, (Vol. 2, 117–122).
|
Eduard Vazquez, & Ramon Baldrich. (2008). Colour Image Segmentation in Presence of Shadows. In 4th European Conference on Colour in Graphics, Imaging and Vision Proceedings (383–387).
|
Arjan Gijsenij, Theo Gevers, & Joost Van de Weijer. (2008). Edge Classification for Color Constancy. In 4th European Conference on Colour in Graphics, Imaging and Vision Proceedings (231–234).
|
Javier Vazquez, Maria Vanrell, & Ramon Baldrich. (2008). Towards a Psychophysical Evaluation of Colour Constancy Algorithms. In 4th European Conference on Colour in Graphics, Imaging and Vision Proceedings (372–377).
|
C. Alejandro Parraga, Robert Benavente, Maria Vanrell, & Ramon Baldrich. (2008). Modelling Inter-Colour Regions of Colour Naming Space. In 4th European Conference on Colour in Graphics, Imaging and Vision Proceedings (218–222).
|
Carme Julia, Angel Sappa, Felipe Lumbreras, & Antonio Lopez. (2008). Recovery of Surface Normals and Reflectance from Different Lighting Conditions. In 5th International Conference on Image Analysis and Recognition (Vol. 5112, 315–325). LNCS.
|
Liu Wenyin, Josep Llados, & Jean-Marc Ogier. (2008). Graphics Recognition. Recent Advances and New Opportunities. (Vol. 5046). LNCS.
|
Bhaskar Chakraborty, Ognjen Rudovic, & Jordi Gonzalez. (2008). View-Invariant Human-Body Detection with Extension to Human Action Recognition using Component-Wise HMM of Body Parts. In 8th IEEE International Conference on Automatic Face and Gesture Recognition.
|
Debora Gil, Jaume Garcia, Mariano Vazquez, Ruth Aris, & Guilleaume Houzeaux. (2008). Patient-Sensitive Anatomic and Functional 3D Model of the Left Ventricle Function. In 8th World Congress on Computational Mechanichs (WCCM8).
Abstract: Early diagnosis and accurate treatment of Left Ventricle (LV) dysfunction significantly increases the patient survival. Impairment of LV contractility due to cardiovascular diseases is reflected in its motion patterns. Recent advances in medical imaging, such as Magnetic Resonance (MR), have encouraged research on 3D simulation and modelling of the LV dynamics. Most of the existing 3D models [1] consider just the gross anatomy of the LV and restore a truncated ellipse which deforms along the cardiac cycle. The contraction mechanics of any muscle strongly depends on the spatial orientation of its muscular fibers since the motion that the muscle undergoes mainly takes place along the fibers. It follows that such simplified models do not allow evaluation of the heart electro-mechanical function and coupling, which has recently risen as the key point for understanding the LV functionality [2]. In order to thoroughly understand the LV mechanics it is necessary to consider the complete anatomy of the LV given by the orientation of the myocardial fibres in 3D space as described by Torrent Guasp [3].
We propose developing a 3D patient-sensitive model of the LV integrating, for the first time, the ven- tricular band anatomy (fibers orientation), the LV gross anatomy and its functionality. Such model will represent the LV function as a natural consequence of its own ventricular band anatomy. This might be decisive in restoring a proper LV contraction in patients undergoing pace marker treatment.
The LV function is defined as soon as the propagation of the contractile electromechanical pulse has been modelled. In our experiments we have used the wave equation for the propagation of the electric pulse. The electromechanical wave moves on the myocardial surface and should have a conductivity tensor oriented along the muscular fibers. Thus, whatever mathematical model for electric pulse propa- gation [4] we consider, the complete anatomy of the LV should be extracted.
The LV gross anatomy is obtained by processing multi slice MR images recorded for each patient. Information about the myocardial fibers distribution can only be extracted by Diffusion Tensor Imag- ing (DTI), which can not provide in vivo information for each patient. As a first approach, we have
Figure 1: Scheme for the Left Ventricle Patient-Sensitive Model.
computed an average model of fibers from several DTI studies of canine hearts. This rough anatomy is the input for our electro-mechanical propagation model simulating LV dynamics. The average fiber orientation is updated until the simulated LV motion agrees with the experimental evidence provided by the LV motion observed in tagged MR (TMR) sequences. Experimental LV motion is recovered by applying image processing, differential geometry and interpolation techniques to 2D TMR slices [5]. The pipeline in figure 1 outlines the interaction between simulations and experimental data leading to our patient-tailored model.
Keywords: Left Ventricle, Electromechanical Models, Image Processing, Magnetic Resonance.
|
Debora Gil, Jaume Garcia, Manuel Vazquez, Ruth Aris, & Guillaume Houzeaux. (2008). Patient-Sensitive Anatomic and Functional 3D Model of the Left Ventricle Function. In 8th World Congress on Computational Mechanichs (WCCM8)/5th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2008). Venezia (Italia).
Abstract: Early diagnosis and accurate treatment of Left Ventricle (LV) dysfunction significantly increases the patient survival. Impairment of LV contractility due to cardiovascular diseases is reflected in its motion patterns. Recent advances in medical imaging, such as Magnetic Resonance (MR), have encouraged research on 3D simulation and modelling of the LV dynamics. Most of the existing 3D models consider just the gross anatomy of the LV and restore a truncated ellipse which deforms along the cardiac cycle. The contraction mechanics of any muscle strongly depends on the spatial orientation of its muscular fibers since the motion that the muscle undergoes mainly takes place along the fibers. It follows that such simplified models do not allow evaluation of the heart electro-mechanical function and coupling, which has recently risen as the key point for understanding the LV functionality . In order to thoroughly understand the LV mechanics it is necessary to consider the complete anatomy of the LV given by the orientation of the myocardial fibres in 3D space as described by Torrent Guasp. We propose developing a 3D patient-sensitive model of the LV integrating, for the first time, the ven- tricular band anatomy (fibers orientation), the LV gross anatomy and its functionality. Such model will represent the LV function as a natural consequence of its own ventricular band anatomy. This might be decisive in restoring a proper LV contraction in patients undergoing pace marker treatment. The LV function is defined as soon as the propagation of the contractile electromechanical pulse has been modelled. In our experiments we have used the wave equation for the propagation of the electric pulse. The electromechanical wave moves on the myocardial surface and should have a conductivity tensor oriented along the muscular fibers. Thus, whatever mathematical model for electric pulse propa- gation [4] we consider, the complete anatomy of the LV should be extracted. The LV gross anatomy is obtained by processing multi slice MR images recorded for each patient. Information about the myocardial fibers distribution can only be extracted by Diffusion Tensor Imag- ing (DTI), which can not provide in vivo information for each patient. As a first approach, we have computed an average model of fibers from several DTI studies of canine hearts. This rough anatomy is the input for our electro-mechanical propagation model simulating LV dynamics. The average fiber orientation is updated until the simulated LV motion agrees with the experimental evidence provided by the LV motion observed in tagged MR (TMR) sequences. Experimental LV motion is recovered by applying image processing, differential geometry and interpolation techniques to 2D TMR slices [5]. The pipeline in figure 1 outlines the interaction between simulations and experimental data leading to our patient-tailored model.
Keywords: Left Ventricle; Electromechanical Models; Image Processing; Magnetic Resonance.
|