Debora Gil. (2004). Geometric Differential Operators for Shape Modelling (Jordi Saludes i Closa, & Petia Radeva, Eds.). Ph.D. thesis, Ediciones Graficas Rey, Barcelona (Spain).
Abstract: Medical imaging feeds research in many computer vision and image processing fields: image filtering, segmentation, shape recovery, registration, retrieval and pattern matching. Because of their low contrast changes and large variety of artifacts and noise, medical imaging processing techniques relying on an analysis of the geometry of image level sets rather than on intensity values result in more robust treatment. From the starting point of treatment of intravascular images, this PhD thesis ad- dresses the design of differential image operators based on geometric principles for a robust shape modelling and restoration. Among all fields applying shape recovery, we approach filtering and segmentation of image objects. For a successful use in real images, the segmentation process should go through three stages: noise removing, shape modelling and shape recovery. This PhD addresses all three topics, but for the sake of algorithms as automated as possible, techniques for image processing will be designed to satisfy three main principles: a) convergence of the iterative schemes to non-trivial states avoiding image degeneration to a constant image and representing smooth models of the originals; b) smooth asymptotic behav- ior ensuring stabilization of the iterative process; c) fixed parameter values ensuring equal (domain free) performance of the algorithms whatever initial images/shapes. Our geometric approach to the generic equations that model the different processes approached enables defining techniques satisfying all the former requirements. First, we introduce a new curvature-based geometric flow for image filtering achieving a good compromise between noise removing and resemblance to original images. Sec- ond, we describe a new family of diffusion operators that restrict their scope to image level curves and serve to restore smooth closed models from unconnected sets of points. Finally, we design a regularization of snake (distance) maps that ensures its smooth convergence towards any closed shape. Experiments show that performance of the techniques proposed overpasses that of state-of-the-art algorithms.
|
Debora Gil, & Petia Radeva. (2004). Inhibition of False Landmarks. In J. V. et al (Ed.), Recent Advances in Artificial Intelligence Research and Development (pp. 233–244). Barcelona (Spain): IOS Press.
Abstract: We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Its high sensitivity to changes in vector directions makes it suitable for landmark location in real images prone to need smoothing to reduce the impact of noise. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our Inhibition Orientation Energy (IOE) landmark locator.
|
Oriol Rodriguez-Leor, Debora Gil, Eduard Fernandez-Nofrerias, H. Tizon, S. Montserrat, Vicente del Valle, et al. (2007). Caracterització de la Perfusió Miocàrdica mitjançant anàlisi estadístic de l espectre en l angiografia de contrast. In XIX Congrés de la Societat Catalana de Cardiologia de Barcelona (130). Barcelona (Spain).
Abstract: La valoració de la integritat de la microcirculació coronària aporta informació pronòstica en pacients amb infart agut de miocardi en els que es realitza angioplastia primària. Aquesta valoració és subjectiva i presenta una important variabilitat si no es duta a terme per personal experimentat. Presentem una eina d’anàlisi d’imatge que permet fer una valoració de la microcirculació coronària a partir de seqüències d’angiografia. Hem analitzat les variacions locals en el nivell de gris de la imatge durant la seqüència angiogràfica. Hem identificat els principals fenòmens observats (respiració, batec cardíac, tinció arterial, tinció miocàrdica i soroll radiològic) mitjançant un anàlisi estadístic de l’espectre de Fourier de l’evolució al llarg del temps de la mitja local. Aquest mateix anàlisis permet determinat la influència de cadascun d’ells en la extracció del patró de tinció i selecciona la respiració com el fenomen que més distorsiona el patró de tinció original. Els descriptors proposats s’obtenen fora del rang espectral respiratori. Hem testat la seva capacitat per a detectar els tres fenòmens principals (tinció miocàrdica (MS), tinció arterial (AS) i soroll (NS)) independentment de la respiració. La capacitat de discriminació dels descriptors ha estat valorada mitjançant un mètode de crossvalidation en 30 seqüències d’angiografia. Els descriptors emprats permeten caracteritzar la tinció miocàrdica amb una alta eficiència i fiabilitat. A més no hi ha diferències significatives en l’anàlisi de les seqüències obtingudes amb el pacient respirant amb normalitat o en apnea
|
Oriol Rodriguez-Leor, Eduard Fernandez-Nofrerias, Josefina Mauri, Vicente del Valle, Debora Gil, A.Barrios, et al. (2006). Perfusion ratio: A new tool to objectively assess microcirculation perfusion after primary Percutaneous Coronary Intervention. In World Congress of Cardiology (859). Barcelona (Spain).
|
Oriol Rodriguez-Leor, Josefina Mauri, Eduard Fernandez-Nofrerias, Vicente de Valle, E. Garcia, A. Barrios, et al. (2006). Analysis of the changes in angiography local grey-level values to determine myocardial perfusion. In World Congress of Cardiology (862). Barcelona (Spain).
|
Patricia Marquez, Debora Gil, & Aura Hernandez-Sabate. (2011). A Confidence Measure for Assessing Optical Flow Accuracy in the Absence of Ground Truth. In IEEE International Conference on Computer Vision – Workshops (pp. 2042–2049). Barcelona (Spain): IEEE.
Abstract: Optical flow is a valuable tool for motion analysis in autonomous navigation systems. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in real world sequences. This paper introduces a measure of optical flow accuracy for Lucas-Kanade based flows in terms of the numerical stability of the data-term. We call this measure optical flow condition number. A statistical analysis over ground-truth data show a good statistical correlation between the condition number and optical flow error. Experiments on driving sequences illustrate its potential for autonomous navigation systems.
Keywords: IEEE International Conference on Computer Vision – Workshops
|
Albert Andaluz, Francesc Carreras, Debora Gil, & Jaume Garcia. (2010). Una aplicació amigable pel càlcul de indicadors clínics del ventricle esquerre. Barcelona: Biocat.
|
Jaume Garcia, Debora Gil, Francesc Carreras, Sandra Pujades, R.Leta, Xavier Alomar, et al. (2008). Patrons de Normalitat Regional per la Valoració de la Funció del Ventricle Esquerre. In XX Congrés de la Societat Catalana de Cardiologia (60). Barcelona.
Abstract: Les malalties cardiovasculars afecten les propietats contràctils de la banda ventricular i provoquen una variació de la funció del Ventricle Esquerre (VE) . Només els indicadors locals (strains, la deformació del teixit) són capaços de detectar anomalies en territoris específics del VE . Patrons de normalitat regionals d’aquests paràmetres serien d’utilitat a l’hora de valorar-ne la funció .
Presentem un Domini Paramètric Normalitzat (DPN) que permet comparar dades de diferents pacients i definir Patrons de Normalitat Regional (PNR)
|
Jaume Garcia, Debora Gil, Francesc Carreras, Sandra Pujades, R.Leta, Xavier Alomar, et al. (2008). Un Model 3D del Ventricle Esquerre Integrant Anatomia i Funcionalitat. In XX Congrés de la Societat Catalana de Cardiologia, Actes del Congres (122). Barcelona.
Abstract: Els canvis en la dinàmica del Ventricle Esquerre (VE) reflecteixen la majoria de malalties cardiovasculars . Els avenços en imatge mèdica han impulsat la recerca en models i simulacions de la dinàmica 3D del VE . La majoria dels models existents sols consideren l’anatomia externa del VE i no permeten una avaluació de l’acoblament electromecànic . Donat que la mecànica d’un muscle depèn de la orientació de les seves fibres, un model realista hauria d’incloure la disposició espacial de la banda ventricular helicoidal (BVH) .
Proposem desenvolupar un model del VE adaptat a cada pacient que integri, per primer cop, l’anatomia de la banda ventricular, l’anatomia externa del VE i la seva funcionalitat, per a una millor determinació del patró d’activació electromecànica
|
Enric Marti, Jaume Rocarias, & Ricardo Toledo. (2008). Caronte: gestión flexible de grupos de alumnos en asignaturas de universidad y actividades sobre estos grupos. Barcelona.
|
Albert Andaluz. (2012). Harmonic Phase Flow: User's guide. Barcelona: CVC.
Abstract: HPF is a plugin for the computation of clinical scores under Osirix.
This manual provides a basic guide for experienced clinical staff. Chapter 1 provides the theoretical background in which this plugin is based.
Next, in chapter 2 we provide basic instructions for installing and uninstalling this plugin. chapter 3we shows a step-by-step scenario to compute clinical scores from tagged-MRI images with HPF. Finally, in chapter 4 we provide a quick guide for plugin developers
|
David Vazquez. (2013). Domain Adaptation of Virtual and Real Worlds for Pedestrian Detection (Antonio Lopez, & Daniel Ponsa, Eds.) (Vol. 1). Ph.D. thesis, Ediciones Graficas Rey, Barcelona.
Abstract: Pedestrian detection is of paramount interest for many applications, e.g. Advanced Driver Assistance Systems, Intelligent Video Surveillance and Multimedia systems. Most promising pedestrian detectors rely on appearance-based classifiers trained with annotated data. However, the required annotation step represents an intensive and subjective task for humans, what makes worth to minimize their intervention in this process by using computational tools like realistic virtual worlds. The reason to use these kind of tools relies in the fact that they allow the automatic generation of precise and rich annotations of visual information. Nevertheless, the use of this kind of data comes with the following question: can a pedestrian appearance model learnt with virtual-world data work successfully for pedestrian detection in real-world scenarios?. To answer this question, we conduct different experiments that suggest a positive answer. However, the pedestrian classifiers trained with virtual-world data can suffer the so called dataset shift problem as real-world based classifiers does. Accordingly, we have designed different domain adaptation techniques to face this problem, all of them integrated in a same framework (V-AYLA). We have explored different methods to train a domain adapted pedestrian classifiers by collecting a few pedestrian samples from the target domain (real world) and combining them with many samples of the source domain (virtual world). The extensive experiments we present show that pedestrian detectors developed within the V-AYLA framework do achieve domain adaptation. Ideally, we would like to adapt our system without any human intervention. Therefore, as a first proof of concept we also propose an unsupervised domain adaptation technique that avoids human intervention during the adaptation process. To the best of our knowledge, this Thesis work is the first demonstrating adaptation of virtual and real worlds for developing an object detector. Last but not least, we also assessed a different strategy to avoid the dataset shift that consists in collecting real-world samples and retrain with them in such a way that no bounding boxes of real-world pedestrians have to be provided. We show that the generated classifier is competitive with respect to the counterpart trained with samples collected by manually annotating pedestrian bounding boxes. The results presented on this Thesis not only end with a proposal for adapting a virtual-world pedestrian detector to the real world, but also it goes further by pointing out a new methodology that would allow the system to adapt to different situations, which we hope will provide the foundations for future research in this unexplored area.
Keywords: Pedestrian Detection; Domain Adaptation
|
Ernest Valveny, & Enric Marti. (1999). Application of deformable template matching to symbol recognition in hand-written architectural draw. In Proceedings of the Fifth International Conference on. Bangalore (India).
Abstract: We propose to use deformable template matching as a new approach to recognize characters and lineal symbols in hand-written line drawings, instead of traditional methods based on vectorization and feature extraction. Bayesian formulation of the deformable template matching allows combining fidelity to the ideal shape of the symbol with maximum flexibility to get the best fit to the input image. Lineal nature of symbols can be exploited to define a suitable representation of models and the set of deformations to be applied to them. Matching, however, is done over the original binary image to avoid losing relevant features during vectorization. We have applied this method to hand-written architectural drawings and experimental results demonstrate that symbols with high distortions from ideal shape can be accurately identified.
|
Enric Marti, Jordi Regincos, Jaime Lopez-Krahe, & Juan J.Villanueva. (1993). Hand line drawing interpretation as three-dimensional objects. Signal Processing – Intelligent systems for signal and image understanding, 32(1-2), 91–110.
Abstract: In this paper we present a technique to interpret hand line drawings as objects in a three-dimensional space. The object domain considered is based on planar surfaces with straight edges, concretely, on ansextension of Origami world to hidden lines. The line drawing represents the object under orthographic projection and it is sensed using a scanner. Our method is structured in two modules: feature extraction and feature interpretation. In the first one, image processing techniques are applied under certain tolerance margins to detect lines and junctions on the hand line drawing. Feature interpretation module is founded on line labelling techniques using a labelled junction dictionary. A labelling algorithm is here proposed. It uses relaxation techniques to reduce the number of incompatible labels with the junction dictionary so that the convergence of solutions can be accelerated. We formulate some labelling hypotheses tending to eliminate elements in two sets of labelled interpretations. That is, those which are compatible with the dictionary but do not correspond to three-dimensional objects and those which represent objects not very probable to be specified by means of a line drawing. New entities arise on the line drawing as a result of the extension of Origami world. These are defined to enunciate the assumptions of our method as well as to clarify the algorithms proposed. This technique is framed in a project aimed to implement a system to create 3D objects to improve man-machine interaction in CAD systems.
Keywords: Line drawing interpretation; line labelling; scene analysis; man-machine interaction; CAD input; line extraction
|
Joel Barajas, Jaume Garcia, Francesc Carreras, Sandra Pujades, & Petia Radeva. (2005). Angle Images Using Gabor Filters in Cardiac Tagged MRI. In Proceeding of the 2005 conference on Artificial Intelligence Research and Development (pp. 107–114). Amsterdam, The Netherlands: IOS Press.
Abstract: Tagged Magnetic Resonance Imaging (MRI) is a non-invasive technique used to examine cardiac deformation in vivo. An Angle Image is a representation of a Tagged MRI which recovers the relative position of the tissue respect to the distorted tags. Thus cardiac deformation can be estimated. This paper describes a new approach to generate Angle Images using a bank of Gabor filters in short axis cardiac Tagged MRI. Our method improves the Angle Images obtained by global techniques, like HARP, with a local frequency analysis. We propose to use the phase response of a combination of a Gabor filters bank, and use it to find a more precise deformation of the left ventricle. We demonstrate the accuracy of our method over HARP by several experimental results.
Keywords: Angle Images, Gabor Filters, Harp, Tagged Mri
|