|
Pierluigi Casale, Oriol Pujol, & Petia Radeva. (2012). Personalization and User Verification in Wearable Systems using Biometric Walking Patterns. PUC - Personal and Ubiquitous Computing, 16(5), 563–580.
Abstract: In this article, a novel technique for user’s authentication and verification using gait as a biometric unobtrusive pattern is proposed. The method is based on a two stages pipeline. First, a general activity recognition classifier is personalized for an specific user using a small sample of her/his walking pattern. As a result, the system is much more selective with respect to the new walking pattern. A second stage verifies whether the user is an authorized one or not. This stage is defined as a one-class classification problem. In order to solve this problem, a four-layer architecture is built around the geometric concept of convex hull. This architecture allows to improve robustness to outliers, modeling non-convex shapes, and to take into account temporal coherence information. Two different scenarios are proposed as validation with two different wearable systems. First, a custom high-performance wearable system is built and used in a free environment. A second dataset is acquired from an Android-based commercial device in a ‘wild’ scenario with rough terrains, adversarial conditions, crowded places and obstacles. Results on both systems and datasets are very promising, reducing the verification error rates by an order of magnitude with respect to the state-of-the-art technologies.
|
|
|
Jose Seabra, Francesco Ciompi, Oriol Pujol, Josepa Mauri, Petia Radeva, & Joao Sanchez. (2011). Rayleigh Mixture Model for Plaque Characterization in Intravascular Ultrasound. TBME - IEEE Transactions on Biomedical Engineering, 58(5), 1314–1324.
Abstract: Vulnerable plaques are the major cause of carotid and coronary vascular problems, such as heart attack or stroke. A correct modeling of plaque echomorphology and composition can help the identification of such lesions. The Rayleigh distribution is widely used to describe (nearly) homogeneous areas in ultrasound images. Since plaques may contain tissues with heterogeneous regions, more complex distributions depending on multiple parameters are usually needed, such as Rice, K or Nakagami distributions. In such cases, the problem formulation becomes more complex, and the optimization procedure to estimate the plaque echomorphology is more difficult. Here, we propose to model the tissue echomorphology by means of a mixture of Rayleigh distributions, known as the Rayleigh mixture model (RMM). The problem formulation is still simple, but its ability to describe complex textural patterns is very powerful. In this paper, we present a method for the automatic estimation of the RMM mixture parameters by means of the expectation maximization algorithm, which aims at characterizing tissue echomorphology in ultrasound (US). The performance of the proposed model is evaluated with a database of in vitro intravascular US cases. We show that the mixture coefficients and Rayleigh parameters explicitly derived from the mixture model are able to accurately describe different plaque types and to significantly improve the characterization performance of an already existing methodology.
|
|
|
Pierluigi Casale, Oriol Pujol, & Petia Radeva. (2011). Human Activity Recognition from Accelerometer Data using a Wearable Device. In J. Vitria, J. M. R. Sanches, & M. Hernández (Eds.), 5th Iberian Conference on Pattern Recognition and Image Analysis (Vol. 6669, pp. 289–296). LNCS. Springer Berlin Heidelberg.
Abstract: Activity Recognition is an emerging field of research, born from the larger fields of ubiquitous computing, context-aware computing and multimedia. Recently, recognizing everyday life activities becomes one of the challenges for pervasive computing. In our work, we developed a novel wearable system easy to use and comfortable to bring. Our wearable system is based on a new set of 20 computationally efficient features and the Random Forest classifier. We obtain very encouraging results with classification accuracy of human activities recognition of up to 94%.
|
|
|
Francesco Ciompi, Oriol Pujol, Carlo Gatta, Xavier Carrillo, Josepa Mauri, & Petia Radeva. (2011). A Holistic Approach for the Detection of Media-Adventitia Border in IVUS. In 14th International Conference on Medical Image Computing and Computer Assisted Intervention (Vol. 6893, pp. 401–408). LNCS. Springer Berlin Heidelberg.
Abstract: In this paper we present a methodology for the automatic detection of media-adventitia border (MAb) in Intravascular Ultrasound. A robust computation of the MAb is achieved through a holistic approach where the position of the MAb with respect to other tissues of the vessel is used. A learned quality measure assures that the resulting MAb is optimal with respect to all other tissues. The mean distance error computed through a set of 140 images is 0.2164 (±0.1326) mm.
|
|
|
Marina Alberti, Carlo Gatta, Simone Balocco, Francesco Ciompi, Oriol Pujol, Joana Silva, et al. (2011). Automatic Branching Detection in IVUS Sequences. In Jordi Vitria, Joao Miguel Raposo, & Mario Hernandez (Eds.), 5th Iberian Conference on Pattern Recognition and Image Analysis (Vol. 6669, pp. 126–133). LNCS. Berlin: Springer Berlin Heidelberg.
Abstract: Atherosclerosis is a vascular pathology affecting the arterial walls, generally located in specific vessel sites, such as bifurcations. In this paper, for the first time, a fully automatic approach for the detection of bifurcations in IVUS pullback sequences is presented. The method identifies the frames and the angular sectors in which a bifurcation is visible. This goal is achieved by applying a classifier to a set of textural features extracted from each image of an IVUS pullback. A comparison between two state-of-the-art classifiers is performed, AdaBoost and Random Forest. A cross-validation scheme is applied in order to evaluate the performances of the approaches. The obtained results are encouraging, showing a sensitivity of 75% and an accuracy of 94% by using the AdaBoost algorithm.
|
|
|
Simone Balocco, Carlo Gatta, Francesco Ciompi, Oriol Pujol, Xavier Carrillo, Josepa Mauri, et al. (2011). Combining Growcut and Temporal Correlation for IVUS Lumen Segmentation. In Jordi Vitria, Joao Miguel Raposo, & Mario Hernandez (Eds.), 5th Iberian Conference on Pattern Recognition and Image Analysis (Vol. 6669, pp. 556–563). LNCS. Berlin: Springer Berlin Heidelberg.
Abstract: The assessment of arterial luminal area, performed by IVUS analysis, is a clinical index used to evaluate the degree of coronary artery disease. In this paper we propose a novel approach to automatically segment the vessel lumen, which combines model-based temporal information extracted from successive frames of the sequence, with spatial classification using the Growcut algorithm. The performance of the method is evaluated by an in vivo experiment on 300 IVUS frames. The automatic and manual segmentation performances in general vessel and stent frames are comparable. The average segmentation error in vessel, stent and bifurcation frames are 0.17±0.08 mm, 0.18±0.07 mm and 0.31±0.12 mm respectively.
|
|
|
Sergio Escalera, David M.J. Tax, Oriol Pujol, Petia Radeva, & Robert P.W. Duin. (2011). Multi-Class Classification in Image Analysis Via Error-Correcting Output Codes. In H. Kawasnicka, & L.Jain (Eds.), Innovations in Intelligent Image Analysis (Vol. 339, pp. 7–29). Berlin: Springer Berlin Heidelberg.
Abstract: A common way to model multi-class classification problems is by means of Error-Correcting Output Codes (ECOC). Given a multi-class problem, the ECOC technique designs a codeword for each class, where each position of the code identifies the membership of the class for a given binary problem.A classification decision is obtained by assigning the label of the class with the closest code. In this paper, we overview the state-of-the-art on ECOC designs and test them in real applications. Results on different multi-class data sets show the benefits of using the ensemble of classifiers when categorizing objects in images.
|
|
|
Antonio Hernandez, Carlo Gatta, Laura Igual, Sergio Escalera, & Petia Radeva. (2011). Automatic Angiography Segmentation Based on Improved Graph-cut. In Jornada TIC Salut Girona.
|
|
|
Laura Igual, Antonio Hernandez, Sergio Escalera, Miguel Reyes, Josep Moya, Joan Carles Soliva, et al. (2011). Automatic Techniques for Studying Attention-Deficit/Hyperactivity Disorder. In Jornada TIC Salut Girona.
|
|
|
Pierluigi Casale, Oriol Pujol, & Petia Radeva. (2011). Approximate Convex Hulls Family for One-Class Cassification. In Carlo Sansone, Josef Kittler, & Fabio Roli (Eds.), 10th International Workshop on Multiple Classifier Systems (Vol. 6713, pp. 106–115). LNCS. Springer Berlin Heidelberg.
Abstract: In this work, a new method for one-class classification based on the Convex Hull geometric structure is proposed. The new method creates a family of convex hulls able to fit the geometrical shape of the training points. The increased computational cost due to the creation of the convex hull in multiple dimensions is circumvented using random projections. This provides an approximation of the original structure with multiple bi-dimensional views. In the projection planes, a mechanism for noisy points rejection has also been elaborated and evaluated. Results show that the approach performs considerably well with respect to the state the art in one-class classification.
|
|
|
Pierluigi Casale, Oriol Pujol, & Petia Radeva. (2011). User Verification From Walking Activity. First Steps Towards a Personal Verification System. In 1st International Conference on Pervasive and Embedded Computing and Communication Systems.
|
|
|
Francesco Ciompi, Oriol Pujol, Simone Balocco, Xavier Carrillo, J. Mauri, & Petia Radeva. (2011). Automatic Key Frames Detection in Intravascular Ultrasound Sequences. In In MICCAI 2011 Workshop on Computing and Visualization for Intra Vascular Imaging.
Abstract: We present a method for the automatic detection of key frames in Intravascular Ultrasound (IVUS) sequences. The key frames are markers delimiting morphological changes along the vessel. The aim of defining key frames is two-fold: (1) they allow to summarize the content of the pullback into few representative frames; (2) they represent the basis for the automatic detection of clinical events in IVUS. The proposed approach achieved a compression ratio of 0.016 with respect to the original sequence and an average inter-frame distance of 61.76 frame, minimizing the number of missed clinical events.
|
|
|
Miguel Reyes, Jose Ramirez Moreno, Juan R Revilla, Petia Radeva, & Sergio Escalera. (2011). ADiBAS: Sistema Multisensor de Adquisicion Automatica de Datos Corporales Objetivos, Robustos y Fiables para el Analisis de la Postura y el Movimiento. In 6th Congreso Iberoamericano de Tecnologia de Apoyo a la Discapacidad (pp. 939–944).
Abstract: El análisis de la postura y del rango de movimiento son fundamentales para conocer la optimización del gesto y mejorar, de este modo, el rendimiento y la detección de posibles lesiones. Esta cuantificación es especialmente interesante en deportistas o en pacientes que presentan alguna lesión neurológica o del sistema musculo-esquelético, ya que permite conocer el proceso evolutivo de estos pacientes, evaluar la eficacia de la terapia aplicada y proponer, en caso necesario, una modificación del protocolo de tratamiento.
En este trabajo presentamos un sistema automático que permite, mediante una tecnología no invasiva, la captación automática de marcadores LED situados sobre el paciente y su posterior análisis con el fin de mostrar al especialista datos objetivos que permitan un mejor soporte diagnóstico. También se describe un
sistema analítico de la postura corporal sin marcadores, donde su ejecución durante secuencias dinámicas aporta un alto grado de naturalidad al paciente a la hora de realizar los ejercicios funcionales.
|
|
|
Antonio Hernandez, Carlo Gatta, Sergio Escalera, Laura Igual, Victoria Martin Yuste, & Petia Radeva. (2011). Accurate and Robust Fully-Automatic QCA: Method and Numerical Validation. In 14th International Conference on Medical Image Computing and Computer Assisted Intervention (Vol. 14, pp. 496–503). Springer.
Abstract: The Quantitative Coronary Angiography (QCA) is a methodology used to evaluate the arterial diseases and, in particular, the degree of stenosis. In this paper we propose AQCA, a fully automatic method for vessel segmentation based on graph cut theory. Vesselness, geodesic paths and a new multi-scale edgeness map are used to compute a globally optimal artery segmentation. We evaluate the method performance in a rigorous numerical way on two datasets. The method can detect an artery with precision 92.9 +/- 5% and sensitivity 94.2 +/- 6%. The average absolute distance error between detected and ground truth centerline is 1.13 +/- 0.11 pixels (about 0.27 +/- 0.025 mm) and the absolute relative error in the vessel caliber estimation is 2.93% with almost no bias. Moreover, the method can discriminate between arteries and catheter with an accuracy of 96.4%.
|
|
|
Xavier Carrillo, E Fernandez-Nofrerias, Francesco Ciompi, Oriol Rodriguez-Leor, Petia Radeva, Neus Salvatella, et al. (2011). Changes in Radial Artery Volume Assessed Using Intravascular Ultrasound: A Comparison of Two Vasodilator Regimens in Transradial Coronary Intervention. JOIC - Journal of Invasive Cardiology, 23(10), 401–404.
Abstract: OBJECTIVES:
This study used intravascular ultrasound (IVUS) to evaluate radial artery volume changes after intraarterial administration of nitroglycerin and/or verapamil.
BACKGROUND:
Radial artery spasm, which is associated with radial artery size, is the main limitation of the transradial approach in percutaneous coronary interventions (PCI).
METHODS:
This prospective, randomized study compared the effect of two intra-arterial vasodilator regimens on radial artery volume: 0.2 mg of nitroglycerin plus 2.5 mg of verapamil (Group 1; n = 15) versus 2.5 mg of verapamil alone (Group 2; n = 15). Radial artery lumen volume was assessed using IVUS at two time points: at baseline (5 minutes after sheath insertion) and post-vasodilator (1 minute after drug administration). The luminal volume of the radial artery was computed using ECOC Random Fields (ECOC-RF), a technique used for automatic segmentation of luminal borders in longitudinal cut images from IVUS sequences.
RESULTS:
There was a significant increase in arterial lumen volume in both groups, with an increase from 451 ± 177 mm³ to 508 ± 192 mm³ (p = 0.001) in Group 1 and from 456 ± 188 mm³ to 509 ± 170 mm³ (p = 0.001) in Group 2. There were no significant differences between the groups in terms of absolute volume increase (58 mm³ versus 53 mm³, respectively; p = 0.65) or in relative volume increase (14% versus 20%, respectively; p = 0.69).
CONCLUSIONS:
Administration of nitroglycerin plus verapamil or verapamil alone to the radial artery resulted in similar increases in arterial lumen volume according to ECOC-RF IVUS measurements.
Keywords: radial; vasodilator treatment; percutaneous coronary intervention; IVUS; volumetric IVUS analysis
|
|