Neus Salvatella, E Fernandez-Nofrerias, Francesco Ciompi, Oriol Rodriguez-Leor, Xavier Carrillo, R. Hemetsberger, et al. (2010). Canvis de volum a la arteria radial despres de la administracio de dos tractaments vasodilatadors. Avaluacio mitjançant ecografia intravascular. In 22nd Congres Societat Catalana de Cardiologia, (179).
|
Oriol Rodriguez-Leor, R. Hemetsberger, Francesco Ciompi, E Fernandez-Nofrerias, Angel Serrano, M. Bernet, et al. (2010). Caracteritzacio automatica de la placa mitjançant analisis del espectre de radiofreqüencia en estudi de ecografia intracoronaria: resultat de la fusio de dades invivo i exvivo. In 22nd Congres Societat Catalana de Cardiologia, (131).
|
Carlo Gatta, Simone Balocco, Francesco Ciompi, R. Hemetsberger, Oriol Rodriguez-Leor, & Petia Radeva. (2010). Real-time gating of IVUS sequences based on motion blur analysis: Method and quantitative validation. In 13th international conference on Medical image computing and computer-assisted intervention (Vol. II, pp. 59–67). Springer-Verlag Berlin.
Abstract: Intravascular Ultrasound (IVUS) is an image-guiding technique for cardiovascular diagnostic, providing cross-sectional images of vessels. During the acquisition, the catheter is pulled back (pullback) at a constant speed in order to acquire spatially subsequent images of the artery. However, during this procedure, the heart twist produces a swinging fluctuation of the probe position along the vessel axis. In this paper we propose a real-time gating algorithm based on the analysis of motion blur variations during the IVUS sequence. Quantitative tests performed on an in-vitro ground truth data base shown that our method is superior to state of the art algorithms both in computational speed and accuracy.
|
Carlo Gatta, Simone Balocco, Victoria Martin Yuste, Ruben Leta, & Petia Radeva. (2011). Non-rigid Multi-modal Registration of Coronary Arteries Using SIFTflow. In Jordi Vitria, Joao Miguel Sanches, & Mario Hernandez (Eds.), 5th Iberian Conference on Pattern Recognition and Image Analysis (Vol. 6669, pp. 159–166). LNCS. Berlin: Springer Berlin Heidelberg.
Abstract: The fusion of clinically relevant information coming from different image modalities is an important topic in medical imaging. In particular, different cardiac imaging modalities provides complementary information for the physician: Computer Tomography Angiography (CTA) provides reliable pre-operative information on arteries geometry, even in the presence of chronic total occlusions, while X-Ray Angiography (XRA) allows intra-operative high resolution projections of a specific artery. The non-rigid registration of arteries between these two modalities is a difficult task. In this paper we propose the use of SIFTflow, in registering CTA and XRA images. At the best of our knowledge, this paper proposed SIFTflow as a XRay-CTA registration method for the first time in the literature. To highlight the arteries, so to guide the registration process, the well known Vesselness method has been employed. Results confirm that, to the aim of registration, the arteries must be highlighted and background objects removed as much as possible. Moreover, the comparison with the well known Free Form Deformation technique, suggests that SIFTflow has a great potential in the registration of multi-modal medical images.
|
Carolina Malagelada, F.De Lorio, Fernando Azpiroz, Santiago Segui, Petia Radeva, Anna Accarino, et al. (2010). Intestinal Dysmotility in Patients with Functional Intestinal Disorders Demonstrated by Computer Vision Analysis of Capsule Endoscopy Images. In 18th United European Gastroenterology Week (Vol. 56, pp. A19–20).
|
Simone Balocco, Carlo Gatta, Xavier Carrillo, J. Mauri, & Petia Radeva. (2011). Plaque Type, Plaque Burden and Wall Shear Stress Relation in Coronary Arteries Assessed by X-ray Angiography and Intravascular Ultrasound: a Qualitative Study. In 14th International Symposium on Applied Sciences in Biomedical and Communication Technologies.
Abstract: In this paper, we present a complete framework that automatically provides fluid-dynamic and plaque analysis from IVUS and Angiographic sequences. Such framework is used to analyze, in three coronary arteries, the relation between wall shear stress with type and amount of plaque. Preliminary qualitative results show an inverse relation between the wall shear stress and the plaque burden, which is confirmed by the fact that the plaque growth is higher on the wall having concave curvature. Regarding the plaque type it was observed that regions having low shear stress are predominantly fibro-lipidic while the heavy calcifications are in general located in areas of the vessel having high WSS.
|
E. Serradell, Adriana Romero, R. Leta, Carlo Gatta, & Francesc Moreno-Noguer. (2011). Simultaneous Correspondence and Non-Rigid 3D Reconstruction of the Coronary Tree from Single X-Ray Images. In 13th IEEE International Conference on Computer Vision (pp. 850–857).
|
Santiago Segui. (2011). Contributions to the Diagnosis of Intestinal Motility by Automatic Image Analysis (Jordi Vitria, Ed.). Ph.D. thesis, Ediciones Graficas Rey, .
Abstract: In the early twenty first century Given Imaging Ltd. presented wireless capsule endoscopy (WCE) as a new technological breakthrough that allowed the visualization of
the intestine by using a small, swallowed camera. This small size device was received
with a high enthusiasm within the medical community, and until now, it is still one
of the medical devices with the highest use growth rate. WCE can be used as a novel
diagnostic tool that presents several clinical advantages, since it is non-invasive and
at the same time it provides, for the first time, a full picture of the small bowel morphology, contents and dynamics. Since its appearance, the WCE has been used to
detect several intestinal dysfunctions such as: polyps, ulcers and bleeding. However,
the visual analysis of WCE videos presents an important drawback: the long time
required by the physicians for proper video visualization. In this sense and regarding
to this limitation, the development of computer aided systems is required for the extensive use of WCE in the medical community.
The work presented in this thesis is a set of contributions for the automatic image
analysis and computer-aided diagnosis of intestinal motility disorders using WCE.
Until now, the diagnosis of small bowel motility dysfunctions was basically performed
by invasive techniques such as the manometry test, which can only be conducted at
some referral centers around the world owing to the complexity of the procedure and
the medial expertise required in the interpretation of the results.
Our contributions are divided in three main blocks:
1. Image analysis by computer vision techniques to detect events in the endoluminal WCE scene. Several methods have been proposed to detect visual events
such as: intestinal contractions, intestinal content, tunnel and wrinkles;
2. Machine learning techniques for the analysis and the manipulation of the data
from WCE. These methods have been proposed in order to overcome the problems that the analysis of WCE presents such as: video acquisition cost, unlabeled data and large number of data;
3. Two different systems for the computer-aided diagnosis of intestinal motility
disorders using WCE. The first system presents a fully automatic method that
aids at discriminating healthy subjects from patients with severe intestinal motor disorders like pseudo-obstruction or food intolerance. The second system presents another automatic method that models healthy subjects and discriminate them from mild intestinal motility patients.
|
Pierluigi Casale. (2011). Approximate Ensemble Methods for Physical Activity Recognition Applications (Oriol Pujol, & Petia Radeva, Eds.). Ph.D. thesis, Ediciones Graficas Rey, .
Abstract: The main interest of this thesis focuses on computational methodologies able to
reduce the degree of complexity of learning algorithms and its application to physical
activity recognition.
Random Projections will be used to reduce the computational complexity in Multiple Classifier Systems. A new boosting algorithm and a new one-class classification
methodology have been developed. In both cases, random projections are used for
reducing the dimensionality of the problem and for generating diversity, exploiting in
this way the benefits that ensembles of classifiers provide in terms of performances
and stability. Moreover, the new one-class classification methodology, based on an ensemble strategy able to approximate a multidimensional convex-hull, has been proved
to over-perform state-of-the-art one-class classification methodologies.
The practical focus of the thesis is towards Physical Activity Recognition. A new
hardware platform for wearable computing application has been developed and used
for collecting data of activities of daily living allowing to study the optimal features
set able to successful classify activities.
Based on the classification methodologies developed and the study conducted on
physical activity classification, a machine learning architecture capable to provide a
continuous authentication mechanism for mobile-devices users has been worked out,
as last part of the thesis. The system, based on a personalized classifier, states on
the analysis of the characteristic gait patterns typical of each individual ensuring an
unobtrusive and continuous authentication mechanism
|
Simeon Petkov, Adriana Romero, Xavier Carrillo, Petia Radeva, & Carlo Gatta. (2012). Robust and accurate diaphragm border detection in cardiac X-Ray angiographies. In Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges (Vol. 7746, pp. 225–234). LNCS.
Abstract: Workshop STACOM, dins del MICCAI
X-ray angiography is the most common imaging modality employed in the diagnosis of coronary diseases prior to or during a catheter-based intervention. The analysis of the patient X-Ray sequence can provide useful information about the degree of arterial stenosis, the myocardial perfusion and other clinical parameters. If the sequence has been acquired to evaluate the perfusion grade, the opacity due to the diaphragm could potentially hinder any kind of visual inspection and make more difficult a computer aided measurements. In this paper we propose an accurate and robust method to automatically identify the diaphragm border in each frame. Quantitative evaluation on a set of 11 sequences shows that the proposed algorithm outperforms previous methods.
|
Francesco Ciompi, Simone Balocco, Carles Caus, J. Mauri, & Petia Radeva. (2013). Stent shape estimation through a comprehensive interpretation of intravascular ultrasound images. In 16th International Conference on Medical Image Computing and Computer Assisted Intervention (Vol. 8150, pp. 345–352). LNCS. Springer Berlin Heidelberg.
Abstract: We present a method for automatic struts detection and stent shape estimation in cross-sectional intravascular ultrasound images. A stent shape is first estimated through a comprehensive interpretation of the vessel morphology, performed using a supervised context-aware multi-class classification scheme. Then, the successive strut identification exploits both local appearance and the defined stent shape. The method is tested on 589 images obtained from 80 patients, achieving a F-measure of 74.1% and an averaged distance between manual and automatic struts of 0.10 mm.
|
Marina Alberti, Simone Balocco, Xavier Carrillo, J. Mauri, & Petia Radeva. (2013). Automatic non-rigid temporal alignment of IVUS sequences: method and quantitative validation. UMB - Ultrasound in Medicine and Biology, 39(9), 1698–712.
Abstract: Clinical studies on atherosclerosis regression/progression performed by intravascular ultrasound analysis would benefit from accurate alignment of sequences of the same patient before and after clinical interventions and at follow-up. In this article, a methodology for automatic alignment of intravascular ultrasound sequences based on the dynamic time warping technique is proposed. The non-rigid alignment is adapted to the specific task by applying it to multidimensional signals describing the morphologic content of the vessel. Moreover, dynamic time warping is embedded into a framework comprising a strategy to address partial overlapping between acquisitions and a term that regularizes non-physiologic temporal compression/expansion of the sequences. Extensive validation is performed on both synthetic and in vivo data. The proposed method reaches alignment errors of approximately 0.43 mm for pairs of sequences acquired during the same intervention phase and 0.77 mm for pairs of sequences acquired at successive intervention stages.
Keywords: Intravascular ultrasound; Dynamic time warping; Non-rigid alignment; Sequence matching; Partial overlapping strategy
|
Adriana Romero, Simeon Petkov, Carlo Gatta, M.Sabate, & Petia Radeva. (2012). Efficient automatic segmentation of vessels. In 16th Conference on Medical Image Understanding and Analysis.
|
Pedro Martins, Carlo Gatta, & Paulo Carvalho. (2012). Feature-driven Maximally Stable Extremal Regions. In 7th International Conference on Computer Vision Theory and Applications (pp. 490–497).
|
Pedro Martins, Paulo Carvalho, & Carlo Gatta. (2012). Context Aware Keypoint Extraction for Robust Image Representation. In 23rd British Machine Vision Conference (100.pp. 1–100.12).
|