Details
   web
Records
Author Carlo Gatta; Juan Diego Gomez; Francesco Ciompi; O. Rodriguez-Leor; Petia Radeva
Title Toward robust myocardial blush grade estimation in contrast angiography Type Conference Article
Year 2009 Publication 4th Iberian Conference on Pattern Recognition and Image Analysis Abbreviated Journal
Volume 5524 Issue Pages 249–256
Keywords
Abstract The assessment of Myocardial Blush Grade after primary angioplasty is a precious diagnostic tool to understand if the patient needs further medication or the use of specifics drugs. Unfortunately, the assessment of MBG is difficult for non highly specialized staff. Experimental data show that there is poor correlation between MBG assessment of low and high specialized staff, thus reducing its applicability. This paper proposes a method able to achieve an objective measure of MBG, or a set of parameters that correlates with the MBG. The method tracks the blush area starting from just one single frame tagged by the physician. As a consequence, the blush area is kept isolated from contaminating phenomena such as diaphragm and arteries movements. We also present a method to extract four parameters that are expected to correlate with the MBG. Preliminary results show that the method is capable of extracting interesting information regarding the behavior of the myocardial perfusion.
Address Póvoa de Varzim, Portugal
Corporate Author Thesis
Publisher Springer Berlin Heidelberg Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title LNCS
Series Volume Series Issue Edition
ISSN 0302-9743 ISBN 978-3-642-02171-8 Medium
Area Expedition Conference IbPRIA
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ GGC2009 Serial 1161
Permanent link to this record
 

 
Author Carlo Gatta; Petia Radeva
Title Bilateral Enhancers Type Conference Article
Year 2009 Publication 16th IEEE International Conference on Image Processing Abbreviated Journal
Volume Issue Pages 3161-3165
Keywords
Abstract Ten years ago the concept of bilateral filtering (BF) became popular in the image processing community. The core of the idea is to blend the effect of a spatial filter, as e.g. the Gaussian filter, with the effect of a filter that acts on image values. The two filters acts on orthogonal domains of a picture: the 2D lattice of the image support and the intensity (or color) domain. The BF approach is an intuitive way to blend these two filters giving rise to algorithms that perform difficult tasks requiring a relatively simple design. In this paper we extend the concept of BF, proposing the bilateral enhancers (BE). We show how to design proper functions to obtain an edge-preserving smoothing and a selective sharpening. Moreover, we show that the proposed algorithm can perform edge-preserving smoothing and selective sharpening simultaneously in a single filtering.
Address Cairo, Egypt
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1522-4880 ISBN 978-1-4244-5653-6 Medium
Area Expedition Conference ICIP
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ GaR2009b Serial 1243
Permanent link to this record
 

 
Author Oscar Camara; Estanislao Oubel; Gemma Piella; Simone Balocco; Mathieu De Craene; Alejandro F. Frangi
Title Multi-sequence Registration of Cine, Tagged and Delay-Enhancement MRI with Shift Correction and Steerable Pyramid-Based Detagging Type Conference Article
Year 2009 Publication 5th International Conference on Functional Imaging and Modeling of the Heart Abbreviated Journal
Volume 5528 Issue Pages 330–338
Keywords
Abstract In this work, we present a registration framework for cardiac cine MRI (cMRI), tagged (tMRI) and delay-enhancement MRI (deMRI), where the two main issues to find an accurate alignment between these images have been taking into account: the presence of tags in tMRI and respiration artifacts in all sequences. A steerable pyramid image decomposition has been used for detagging purposes since it is suitable to extract high-order oriented structures by directional adaptive filtering. Shift correction of cMRI is achieved by firstly maximizing the similarity between the Long Axis and Short Axis cMRI. Subsequently, these shift-corrected images are used as target images in a rigid registration procedure with their corresponding tMRI/deMRI in order to correct their shift. The proposed registration framework has been evaluated by 840 registration tests, considerably improving the alignment of the MR images (mean RMS error of 2.04mm vs. 5.44mm).
Address Nice, France
Corporate Author Thesis
Publisher Springer Berlin Heidelberg Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title LNCS
Series Volume Series Issue Edition
ISSN 0302-9743 ISBN 978-3-642-01931-9 Medium
Area Expedition Conference FIMH
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ COP2009 Serial 1255
Permanent link to this record
 

 
Author David Rotger; Petia Radeva; N. Bruining
Title Automatic Detection of Bioabsorbable Coronary Stents in IVUS Images using a Cascade of Classifiers Type Journal Article
Year 2010 Publication IEEE Transactions on Information Technology in Biomedicine Abbreviated Journal TITB
Volume 14 Issue 2 Pages 535 – 537
Keywords
Abstract Bioabsorbable drug-eluting coronary stents present a very promising improvement to the common metallic ones solving some of the most important problems of stent implantation: the late restenosis. These stents made of poly-L-lactic acid cause a very subtle acoustic shadow (compared to the metallic ones) making difficult the automatic detection and measurements in images. In this paper, we propose a novel approach based on a cascade of GentleBoost classifiers to detect the stent struts using structural features to code the information of the different subregions of the struts. A stochastic gradient descent method is applied to optimize the overall performance of the detector. Validation results of struts detection are very encouraging with an average F-measure of 81%.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ RRB2010 Serial 1287
Permanent link to this record
 

 
Author Simone Balocco; O. Basset; G. Courbebaisse; E. Boni; Alejandro F. Frangi; P. Tortoli; C. Cachard
Title Estimation Of Viscoelastic Properties Of Vessel Walls Using a Computational Model and Doppler Ultrasound Type Journal Article
Year 2010 Publication Physics in Medicine and Biology Abbreviated Journal PMB
Volume 55 Issue 12 Pages 3557–3575
Keywords
Abstract Human arteries affected by atherosclerosis are characterized by altered wall viscoelastic properties. The possibility of noninvasively assessing arterial viscoelasticity in vivo would significantly contribute to the early diagnosis and prevention of this disease. This paper presents a noniterative technique to estimate the viscoelastic parameters of a vascular wall Zener model. The approach requires the simultaneous measurement of flow variations and wall displacements, which can be provided by suitable ultrasound Doppler instruments. Viscoelastic parameters are estimated by fitting the theoretical constitutive equations to the experimental measurements using an ARMA parameter approach. The accuracy and sensitivity of the proposed method are tested using reference data generated by numerical simulations of arterial pulsation in which the physiological conditions and the viscoelastic parameters of the model can be suitably varied. The estimated values quantitatively agree with the reference values, showing that the only parameter affected by changing the physiological conditions is viscosity, whose relative error was about 27% even when a poor signal-to-noise ratio is simulated. Finally, the feasibility of the method is illustrated through three measurements made at different flow regimes on a cylindrical vessel phantom, yielding a parameter mean estimation error of 25%.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ BBC2010 Serial 1312
Permanent link to this record
 

 
Author Simone Balocco; O. Camara; E. Vivas; T. Sola; L. Guimaraens; H. A. van Andel; C. B. Majoie; J. M. Pozo; B. H. Bijnens; Alejandro F. Frangi
Title Feasibility of Estimating Regional Mechanical Properties of Cerebral Aneurysms In Vivo Type Journal Article
Year 2010 Publication Medical Physics Abbreviated Journal MEDPHYS
Volume 37 Issue 4 Pages 1689–1706
Keywords
Abstract PURPOSE:
In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior.
METHODS:
A data assimilation framework was developed to incorporate patient-specific geometries into a given biomechanical model, whereas wall motion estimates were obtained from applying registration techniques to a pair of simulated MR images and guided the mechanical parameter estimation. A simple incompressible linear and isotropic Hookean model coupled with computational fluid-dynamics was employed as a first approximation for computational purposes. Additionally, an automatic clustering technique was developed to reduce the number of parameters to assimilate at the optimization stage and it considerably accelerated the convergence of the simulations. Several in silico experiments were designed to assess the influence of aneurysm geometrical characteristics and the accuracy of wall motion estimates on the mechanical property estimates. Hence, the proposed methodology was applied to six real cerebral aneurysms and tested against a varying number of regions with different elasticity, different mesh discretization, imaging resolution, and registration configurations.
RESULTS:
Several in silico experiments were conducted to investigate the feasibility of the proposed workflow, results found suggesting that the estimation of the mechanical properties was mainly influenced by the image spatial resolution and the chosen registration configuration. According to the in silico experiments, the minimal spatial resolution needed to extract wall pulsation measurements with enough accuracy to guide the proposed data assimilation framework was of 0.1 mm.
CONCLUSIONS:
Current routine imaging modalities do not have such a high spatial resolution and therefore the proposed data assimilation framework cannot currently be used on in vivo data to reliably estimate regional properties in cerebral aneurysms. Besides, it was observed that the incorporation of fluid-structure interaction in a biomechanical model with linear and isotropic material properties did not have a substantial influence in the final results.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ BCV2010 Serial 1313
Permanent link to this record
 

 
Author Neus Salvatella; E Fernandez-Nofrerias; Francesco Ciompi; O. Rodriguez-Leor; H. Tizon; Xavier Carrillo; Josefina Mauri; Petia Radeva
Title Radial Artery Volume Changes After Administration Of Two Different Intra-arterial Drug Regimens. Assessment by Intravascular Ultrasound Type Journal Article
Year 2010 Publication Journal of the American College of Cardiology Abbreviated Journal JACC
Volume 56 Issue 13s1 Pages B119
Keywords
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ SFC2010b Serial 1364
Permanent link to this record
 

 
Author Jose Seabra; F. Javier Sanchez; Francesco Ciompi; Petia Radeva
Title Ultrasonographic Plaque Characterization using a Rayleigh Mixture Model Type Conference Article
Year 2010 Publication 7th IEEE International Symposium on Biomedical Imaging Abbreviated Journal
Volume Issue Pages 1–4
Keywords
Abstract From Nano to Macro
A correct modelling of tissue morphology is determinant for the identification of vulnerable plaques. This paper aims at describing the plaque composition by means of a Rayleigh Mixture Model applied to ultrasonic data. The effectiveness of using a mixture of distributions is established through synthetic and real ultrasonic data samples. Furthermore, the proposed mixture model is used in a plaque classification problem in Intravascular Ultrasound (IVUS) images of coronary plaques. A classifier tested on a set of 67 in-vitro plaques, yields an overall accuracy of 86% and sensitivity of 92%, 94% and 82%, for fibrotic, calcified and lipidic tissues, respectively. These results strongly suggest that different plaques types can be distinguished by means of the coefficients and Rayleigh parameters of the mixture distribution.
Address Rotterdam (Netherlands)
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1945-7928 ISBN 978-1-4244-4125-9 Medium
Area Expedition Conference ISBI
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ SSC2010 Serial 1366
Permanent link to this record
 

 
Author Neus Salvatella; E Fernandez-Nofrerias; Francesco Ciompi; O. Rodriguez-Leor; Xavier Carrillo; R. Hemetsberger; Petia Radeva; Josefina Mauri; A. Bayes
Title Canvis de volum a la arteria radial despres de la administracio de dos tractaments vasodilatadors. Avaluacio mitjançant ecografia intravascular Type Conference Article
Year 2010 Publication 22nd Congres Societat Catalana de Cardiologia, Abbreviated Journal
Volume Issue Pages 179
Keywords
Abstract
Address Barcelona (Spain)
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ SFC2010a Serial 1367
Permanent link to this record
 

 
Author O. Rodriguez-Leor; R. Hemetsberger; Francesco Ciompi; E Fernandez-Nofrerias; Angel Serrano; M. Bernet; Petia Radeva; F. Mauri; A. Bayes
Title Caracteritzacio automatica de la placa mitjançant analisis del espectre de radiofreqüencia en estudi de ecografia intracoronaria: resultat de la fusio de dades invivo i exvivo Type Conference Article
Year 2010 Publication 22nd Congres Societat Catalana de Cardiologia, Abbreviated Journal
Volume Issue Pages 131
Keywords
Abstract
Address Barcelona (Spain)
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ RHC2010 Serial 1368
Permanent link to this record
 

 
Author Carlo Gatta; Simone Balocco; Francesco Ciompi; R. Hemetsberger; O. Rodriguez-Leor; Petia Radeva
Title Real-time gating of IVUS sequences based on motion blur analysis: Method and quantitative validation Type Conference Article
Year 2010 Publication 13th international conference on Medical image computing and computer-assisted intervention Abbreviated Journal
Volume II Issue Pages 59-67
Keywords
Abstract Intravascular Ultrasound (IVUS) is an image-guiding technique for cardiovascular diagnostic, providing cross-sectional images of vessels. During the acquisition, the catheter is pulled back (pullback) at a constant speed in order to acquire spatially subsequent images of the artery. However, during this procedure, the heart twist produces a swinging fluctuation of the probe position along the vessel axis. In this paper we propose a real-time gating algorithm based on the analysis of motion blur variations during the IVUS sequence. Quantitative tests performed on an in-vitro ground truth data base shown that our method is superior to state of the art algorithms both in computational speed and accuracy.
Address
Corporate Author Thesis
Publisher Springer-Verlag Berlin Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference MICCAI
Notes (down) MILAB Approved no
Call Number BCNPCL @ bcnpcl @ GBC2010 Serial 1447
Permanent link to this record
 

 
Author Carlo Gatta; Simone Balocco; Victoria Martin Yuste; Ruben Leta; Petia Radeva
Title Non-rigid Multi-modal Registration of Coronary Arteries Using SIFTflow Type Conference Article
Year 2011 Publication 5th Iberian Conference on Pattern Recognition and Image Analysis Abbreviated Journal
Volume 6669 Issue Pages 159-166
Keywords
Abstract The fusion of clinically relevant information coming from different image modalities is an important topic in medical imaging. In particular, different cardiac imaging modalities provides complementary information for the physician: Computer Tomography Angiography (CTA) provides reliable pre-operative information on arteries geometry, even in the presence of chronic total occlusions, while X-Ray Angiography (XRA) allows intra-operative high resolution projections of a specific artery. The non-rigid registration of arteries between these two modalities is a difficult task. In this paper we propose the use of SIFTflow, in registering CTA and XRA images. At the best of our knowledge, this paper proposed SIFTflow as a XRay-CTA registration method for the first time in the literature. To highlight the arteries, so to guide the registration process, the well known Vesselness method has been employed. Results confirm that, to the aim of registration, the arteries must be highlighted and background objects removed as much as possible. Moreover, the comparison with the well known Free Form Deformation technique, suggests that SIFTflow has a great potential in the registration of multi-modal medical images.
Address Las Palmas de Gran Canaria. Spain
Corporate Author Thesis
Publisher Springer Berlin Heidelberg Place of Publication Berlin Editor Jordi Vitria; Joao Miguel Sanches; Mario Hernandez
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title LNCS
Series Volume Series Issue Edition
ISSN 0302-9743 ISBN 978-3-642-21256-7 Medium
Area Expedition Conference IbPRIA
Notes (down) MILAB Approved no
Call Number Admin @ si @ GBM2011 Serial 1752
Permanent link to this record
 

 
Author Carolina Malagelada; F.De Lorio; Fernando Azpiroz; Santiago Segui; Petia Radeva; Anna Accarino; J.Santos; Juan R. Malagelada
Title Intestinal Dysmotility in Patients with Functional Intestinal Disorders Demonstrated by Computer Vision Analysis of Capsule Endoscopy Images Type Conference Article
Year 2010 Publication 18th United European Gastroenterology Week Abbreviated Journal
Volume 56 Issue 3 Pages A19-20
Keywords
Abstract
Address Barcelona
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference UEGW
Notes (down) MILAB Approved no
Call Number Admin @ si @ MLA2010 Serial 1779
Permanent link to this record
 

 
Author Simone Balocco; Carlo Gatta; Xavier Carrillo; F. Mauri; Petia Radeva
Title Plaque Type, Plaque Burden and Wall Shear Stress Relation in Coronary Arteries Assessed by X-ray Angiography and Intravascular Ultrasound: a Qualitative Study Type Conference Article
Year 2011 Publication 14th International Symposium on Applied Sciences in Biomedical and Communication Technologies Abbreviated Journal
Volume Issue Pages
Keywords
Abstract In this paper, we present a complete framework that automatically provides fluid-dynamic and plaque analysis from IVUS and Angiographic sequences. Such framework is used to analyze, in three coronary arteries, the relation between wall shear stress with type and amount of plaque. Preliminary qualitative results show an inverse relation between the wall shear stress and the plaque burden, which is confirmed by the fact that the plaque growth is higher on the wall having concave curvature. Regarding the plaque type it was observed that regions having low shear stress are predominantly fibro-lipidic while the heavy calcifications are in general located in areas of the vessel having high WSS.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN 978-1-4503-0913-4 Medium
Area Expedition Conference ISABEL
Notes (down) MILAB Approved no
Call Number Admin @ si @ BGC2011b Serial 1799
Permanent link to this record
 

 
Author E. Serradell; Adriana Romero; R. Leta; Carlo Gatta; Francesc Moreno-Noguer
Title Simultaneous Correspondence and Non-Rigid 3D Reconstruction of the Coronary Tree from Single X-Ray Images Type Conference Article
Year 2011 Publication 13th IEEE International Conference on Computer Vision Abbreviated Journal
Volume Issue Pages 850-857
Keywords
Abstract
Address Barcelona
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference ICCV
Notes (down) MILAB Approved no
Call Number Admin @ si @ SRL2011 Serial 1803
Permanent link to this record