|
Records |
Links |
|
Author |
Sergio Escalera; Alicia Fornes; Oriol Pujol; Josep Llados; Petia Radeva |
|
|
Title |
Circular Blurred Shape Model for Multiclass Symbol Recognition |
Type |
Journal Article |
|
Year |
2011 |
Publication |
IEEE Transactions on Systems, Man and Cybernetics (Part B) (IEEE) |
Abbreviated Journal |
TSMCB |
|
|
Volume |
41 |
Issue |
2 |
Pages |
497-506 |
|
|
Keywords |
|
|
|
Abstract |
In this paper, we propose a circular blurred shape model descriptor to deal with the problem of symbol detection and classification as a particular case of object recognition. The feature extraction is performed by capturing the spatial arrangement of significant object characteristics in a correlogram structure. The shape information from objects is shared among correlogram regions, where a prior blurring degree defines the level of distortion allowed in the symbol, making the descriptor tolerant to irregular deformations. Moreover, the descriptor is rotation invariant by definition. We validate the effectiveness of the proposed descriptor in both the multiclass symbol recognition and symbol detection domains. In order to perform the symbol detection, the descriptors are learned using a cascade of classifiers. In the case of multiclass categorization, the new feature space is learned using a set of binary classifiers which are embedded in an error-correcting output code design. The results over four symbol data sets show the significant improvements of the proposed descriptor compared to the state-of-the-art descriptors. In particular, the results are even more significant in those cases where the symbols suffer from elastic deformations. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1083-4419 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB; DAG;HuPBA |
Approved |
no |
|
|
Call Number |
Admin @ si @ EFP2011 |
Serial |
1784 |
|
Permanent link to this record |
|
|
|
|
Author |
G. Zahnd; Simone Balocco; A. Serusclat; P. Moulin; M. Orkisz; D. Vray |
|
|
Title |
Progressive attenuation of the longitudinal kinetics in the common carotid artery: preliminary in vivo assessment Ultrasound in Medicine and Biology |
Type |
Journal Article |
|
Year |
2015 |
Publication |
Ultrasound in Medicine and Biology |
Abbreviated Journal |
UMB |
|
|
Volume |
41 |
Issue |
1 |
Pages |
339-345 |
|
|
Keywords |
Arterial stiffness; Atherosclerosis; Common carotid artery; Longitudinal kinetics; Motion tracking; Ultrasound imaging |
|
|
Abstract |
Longitudinal kinetics (LOKI) of the arterial wall consists of the shearing motion of the intima-media complex over the adventitia layer in the direction parallel to the blood flow during the cardiac cycle. The aim of this study was to investigate the local variability of LOKI amplitude along the length of the vessel. By use of a previously validated motion-estimation framework, 35 in vivo longitudinal B-mode ultrasound cine loops of healthy common carotid arteries were analyzed. Results indicated that LOKI amplitude is progressively attenuated along the length of the artery, as it is larger in regions located on the proximal side of the image (i.e., toward the heart) and smaller in regions located on the distal side of the image (i.e., toward the head), with an average attenuation coefficient of -2.5 ± 2.0%/mm. Reported for the first time in this study, this phenomenon is likely to be of great importance in improving understanding of atherosclerosis mechanisms, and has the potential to be a novel index of arterial stiffness. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB |
Approved |
no |
|
|
Call Number |
Admin @ si @ ZBS2014 |
Serial |
2556 |
|
Permanent link to this record |
|
|
|
|
Author |
Tadashi Araki; Sumit K. Banchhor; Narendra D. Londhe; Nobutaka Ikeda; Petia Radeva; Devarshi Shukla; Luca Saba; Antonella Balestrieri; Andrew Nicolaides; Shoaib Shafique; John R. Laird; Jasjit S. Suri |
|
|
Title |
Reliable and Accurate Calcium Volume Measurement in Coronary Artery Using Intravascular Ultrasound Videos |
Type |
Journal Article |
|
Year |
2016 |
Publication |
Journal of Medical Systems |
Abbreviated Journal |
JMS |
|
|
Volume |
40 |
Issue |
3 |
Pages |
51:1-51:20 |
|
|
Keywords |
Interventional cardiology; Atherosclerosis; Coronary arteries; IVUS; calcium volume; Soft computing; Performance Reliability; Accuracy |
|
|
Abstract |
Quantitative assessment of calcified atherosclerotic volume within the coronary artery wall is vital for cardiac interventional procedures. The goal of this study is to automatically measure the calcium volume, given the borders of coronary vessel wall for all the frames of the intravascular ultrasound (IVUS) video. Three soft computing fuzzy classification techniques were adapted namely Fuzzy c-Means (FCM), K-means, and Hidden Markov Random Field (HMRF) for automated segmentation of calcium regions and volume computation. These methods were benchmarked against previously developed threshold-based method. IVUS image data sets (around 30,600 IVUS frames) from 15 patients were collected using 40 MHz IVUS catheter (Atlantis® SR Pro, Boston Scientific®, pullback speed of 0.5 mm/s). Calcium mean volume for FCM, K-means, HMRF and threshold-based method were 37.84 ± 17.38 mm3, 27.79 ± 10.94 mm3, 46.44 ± 19.13 mm3 and 35.92 ± 16.44 mm3 respectively. Cross-correlation, Jaccard Index and Dice Similarity were highest between FCM and threshold-based method: 0.99, 0.92 ± 0.02 and 0.95 + 0.02 respectively. Student’s t-test, z-test and Wilcoxon-test are also performed to demonstrate consistency, reliability and accuracy of the results. Given the vessel wall region, the system reliably and automatically measures the calcium volume in IVUS videos. Further, we validated our system against a trained expert using scoring: K-means showed the best performance with an accuracy of 92.80 %. Out procedure and protocol is along the line with method previously published clinically. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB; |
Approved |
no |
|
|
Call Number |
Admin @ si @ ABL2016 |
Serial |
2729 |
|
Permanent link to this record |
|
|
|
|
Author |
Marina Alberti; Simone Balocco; Xavier Carrillo; J. Mauri; Petia Radeva |
|
|
Title |
Automatic non-rigid temporal alignment of IVUS sequences: method and quantitative validation |
Type |
Journal Article |
|
Year |
2013 |
Publication |
Ultrasound in Medicine and Biology |
Abbreviated Journal |
UMB |
|
|
Volume |
39 |
Issue |
9 |
Pages |
1698-712 |
|
|
Keywords |
Intravascular ultrasound; Dynamic time warping; Non-rigid alignment; Sequence matching; Partial overlapping strategy |
|
|
Abstract |
Clinical studies on atherosclerosis regression/progression performed by intravascular ultrasound analysis would benefit from accurate alignment of sequences of the same patient before and after clinical interventions and at follow-up. In this article, a methodology for automatic alignment of intravascular ultrasound sequences based on the dynamic time warping technique is proposed. The non-rigid alignment is adapted to the specific task by applying it to multidimensional signals describing the morphologic content of the vessel. Moreover, dynamic time warping is embedded into a framework comprising a strategy to address partial overlapping between acquisitions and a term that regularizes non-physiologic temporal compression/expansion of the sequences. Extensive validation is performed on both synthetic and in vivo data. The proposed method reaches alignment errors of approximately 0.43 mm for pairs of sequences acquired during the same intervention phase and 0.77 mm for pairs of sequences acquired at successive intervention stages. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB |
Approved |
no |
|
|
Call Number |
Admin @ si @ ABC2013 |
Serial |
2313 |
|
Permanent link to this record |
|
|
|
|
Author |
Simone Balocco; Carlo Gatta; Marina Alberti; Xavier Carrillo; Juan Rigla; Petia Radeva |
|
|
Title |
Relation between plaque type, plaque thickness, blood shear stress and plaque stress in coronary arteries assessed by X-ray Angiography and Intravascular Ultrasound |
Type |
Journal Article |
|
Year |
2012 |
Publication |
Medical Physics |
Abbreviated Journal |
MEDPHYS |
|
|
Volume |
39 |
Issue |
12 |
Pages |
7430-7445 |
|
|
Keywords |
|
|
|
Abstract |
PMID 23231293
PURPOSE:
Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries.
METHODS:
First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound (IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations.
RESULTS:
The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall.
CONCLUSIONS:
Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB |
Approved |
no |
|
|
Call Number |
Admin @ si @BGA2012 |
Serial |
2170 |
|
Permanent link to this record |