E. Provenzi, Carlo Gatta, M. Fierro, & A. Rizzi. (2008). A Spatially Variant White-Patch and Gray-World Method for Color Image Enhancement Driven by Local Constant. TPAMI - IEEE Transactions on Pattern Analysis and Machine Intelligence, 1757–1770.
|
|
|
Carolina Malagelada, Fosca De Iorio, Fernando Azpiroz, Anna Accarino, Santiago Segui, Petia Radeva, et al. (2008). New Insight Into Intestinal Motor Function via Noninvasive Endoluminal Image Analysis. Gastroenterology, 1155–1162.
|
|
|
C. Butakoff, Simone Balocco, F.M. Sukno, C. Hoogendoorn, C. Tobon-Gomez, G. Avegliano, et al. (2016). Left-ventricular Epi- and Endocardium Extraction from 3D Ultrasound Images Using an Automatically Constructed 3D ASM. CMBBE - Computer Methods in Biomechanics and Biomedical Engineering: Imaging and Visualization, 4(5), 265–280.
Abstract: In this paper, we propose an automatic method for constructing an active shape model (ASM) to segment the complete cardiac left ventricle in 3D ultrasound (3DUS) images, which avoids costly manual landmarking. The automatic construction of the ASM has already been addressed in the literature; however, the direct application of these methods to 3DUS is hampered by a high level of noise and artefacts. Therefore, we propose to construct the ASM by fusing the multidetector computed tomography data, to learn the shape, with the artificially generated 3DUS, in order to learn the neighbourhood of the boundaries. Our artificial images were generated by two approaches: a faster one that does not take into account the geometry of the transducer, and a more comprehensive one, implemented in Field II toolbox. The segmentation accuracy of our ASM was evaluated on 20 patients with left-ventricular asynchrony, demonstrating plausibility of the approach.
Keywords: ASM; cardiac segmentation; statistical model; shape model; 3D ultrasound; cardiac segmentation
|
|
|
David Rotger, Petia Radeva, & N. Bruining. (2010). Automatic Detection of Bioabsorbable Coronary Stents in IVUS Images using a Cascade of Classifiers. TITB - IEEE Transactions on Information Technology in Biomedicine, 14(2), 535 – 537.
Abstract: Bioabsorbable drug-eluting coronary stents present a very promising improvement to the common metallic ones solving some of the most important problems of stent implantation: the late restenosis. These stents made of poly-L-lactic acid cause a very subtle acoustic shadow (compared to the metallic ones) making difficult the automatic detection and measurements in images. In this paper, we propose a novel approach based on a cascade of GentleBoost classifiers to detect the stent struts using structural features to code the information of the different subregions of the struts. A stochastic gradient descent method is applied to optimize the overall performance of the detector. Validation results of struts detection are very encouraging with an average F-measure of 81%.
|
|
|
Simone Balocco, O. Basset, G. Courbebaisse, E. Boni, Alejandro F. Frangi, P. Tortoli, et al. (2010). Estimation Of Viscoelastic Properties Of Vessel Walls Using a Computational Model and Doppler Ultrasound. PMB - Physics in Medicine and Biology, 55(12), 3557–3575.
Abstract: Human arteries affected by atherosclerosis are characterized by altered wall viscoelastic properties. The possibility of noninvasively assessing arterial viscoelasticity in vivo would significantly contribute to the early diagnosis and prevention of this disease. This paper presents a noniterative technique to estimate the viscoelastic parameters of a vascular wall Zener model. The approach requires the simultaneous measurement of flow variations and wall displacements, which can be provided by suitable ultrasound Doppler instruments. Viscoelastic parameters are estimated by fitting the theoretical constitutive equations to the experimental measurements using an ARMA parameter approach. The accuracy and sensitivity of the proposed method are tested using reference data generated by numerical simulations of arterial pulsation in which the physiological conditions and the viscoelastic parameters of the model can be suitably varied. The estimated values quantitatively agree with the reference values, showing that the only parameter affected by changing the physiological conditions is viscosity, whose relative error was about 27% even when a poor signal-to-noise ratio is simulated. Finally, the feasibility of the method is illustrated through three measurements made at different flow regimes on a cylindrical vessel phantom, yielding a parameter mean estimation error of 25%.
|
|