|
Andres Traumann, Gholamreza Anbarjafari, & Sergio Escalera. (2015). Accurate 3D Measurement Using Optical Depth Information. EL - Electronic Letters, 51(18), 1420–1422.
Abstract: A novel three-dimensional measurement technique is proposed. The methodology consists in mapping from the screen coordinates reported by the optical camera to the real world, and integrating distance gradients from the beginning to the end point, while also minimising the error through fitting pixel locations to a smooth curve. The results demonstrate accuracy of less than half a centimetre using Microsoft Kinect II.
|
|
|
Amir A.Amini, Yasheng Chen, Mohamed Elayyadi, & Petia Radeva. (2001). Tag Surface Reconstruction and Tracking of Myocardial Beads from SPAMM-MRI with Parametric B-Spline Surfaces. TMI - IEEE Transactions on Medical Imaging, 94–103.
Abstract: Magnetic resonance imaging (MRI) is unique in its ability to noninvasively and selectively alter tissue magnetization, and create tag planes intersecting image slices. The resulting grid of signal voids allows for tracking deformations of tissues in otherwise homogeneous-signal myocardial regions. In this paper, we propose a specific spatial modulation of magnetization (SPAMM) imaging protocol together with efficient techniques for measurement of three-dimensional (3-D) motion of material points of the human heart (referred to as myocardial beads) from images collected with the SPAMM method. The techniques make use of tagged images in orthogonal views by explicitly reconstructing 3-D B-spline surface representation of tag planes (tag planes in two orthogonal orientations intersecting the short-axis (SA) image slices and tag planes in an orientation orthogonal to the short-axis tag planes intersecting long-axis (LA) image slices). The developed methods allow for viewing deformations of 3-D tag surfaces, spatial correspondence of long-axis and short-axis image slice and tag positions, as well as nonrigid movement of myocardial beads as a function of time.
Keywords: B-spline surfaces, cardiac motion, myocardial beads, myocardial infarction, tagged MRI.
|
|
|
Oriol Rodriguez-Leon, Josefina Mauri, Eduard Fernandez-Nofrerias, Antonio Tovar, Vicente del Valle, Aura Hernandez-Sabate, et al. (2004). Utilizacion de la estructura de los campos vectoriales para la deteccion de la Adventicia en imagenes de Ecografia Intracoronaria. REC - Revista Española de Cardiología, 100.
|
|
|
Oriol Pujol, Sergio Escalera, & Petia Radeva. (2008). An Incremental Node Embedding Technique for Error Correcting Output Codes. PR - Pattern Recognition, 713–725.
|
|
|
Sergio Escalera, Oriol Pujol, & Petia Radeva. (2010). Traffic sign recognition system with β -correction. MVA - Machine Vision and Applications, 21(2), 99–111.
Abstract: Traffic sign classification represents a classical application of multi-object recognition processing in uncontrolled adverse environments. Lack of visibility, illumination changes, and partial occlusions are just a few problems. In this paper, we introduce a novel system for multi-class classification of traffic signs based on error correcting output codes (ECOC). ECOC is based on an ensemble of binary classifiers that are trained on bi-partition of classes. We classify a wide set of traffic signs types using robust error correcting codings. Moreover, we introduce the novel β-correction decoding strategy that outperforms the state-of-the-art decoding techniques, classifying a high number of classes with great success.
|
|