toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author Mireia Sole; Joan Blanco; Debora Gil; G. Fonseka; Richard Frodsham; Oliver Valero; Francesca Vidal; Zaida Sarrate edit  openurl
  Title Análisis 3d de la territorialidad cromosómica en células espermatogénicas: explorando la infertilidad desde un nuevo prisma Type Journal
  Year 2017 Publication Revista Asociación para el Estudio de la Biología de la Reproducción Abbreviated Journal ASEBIR  
  Volume 22 Issue 2 Pages 105  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN (up) Medium  
  Area Expedition Conference  
  Notes IAM; 600.096; 600.145 Approved no  
  Call Number Admin @ si @ SBG2017d Serial 3042  
Permanent link to this record
 

 
Author Debora Gil; Rosa Maria Ortiz; Carles Sanchez; Antoni Rosell edit   pdf
doi  openurl
  Title Objective endoscopic measurements of central airway stenosis. A pilot study Type Journal Article
  Year 2018 Publication Respiration Abbreviated Journal RES  
  Volume 95 Issue Pages 63–69  
  Keywords Bronchoscopy; Tracheal stenosis; Airway stenosis; Computer-assisted analysis  
  Abstract Endoscopic estimation of the degree of stenosis in central airway obstruction is subjective and highly variable. Objective: To determine the benefits of using SENSA (System for Endoscopic Stenosis Assessment), an image-based computational software, for obtaining objective stenosis index (SI) measurements among a group of expert bronchoscopists and general pulmonologists. Methods: A total of 7 expert bronchoscopists and 7 general pulmonologists were enrolled to validate SENSA usage. The SI obtained by the physicians and by SENSA were compared with a reference SI to set their precision in SI computation. We used SENSA to efficiently obtain this reference SI in 11 selected cases of benign stenosis. A Web platform with three user-friendly microtasks was designed to gather the data. The users had to visually estimate the SI from videos with and without contours of the normal and the obstructed area provided by SENSA. The users were able to modify the SENSA contours to define the reference SI using morphometric bronchoscopy. Results: Visual SI estimation accuracy was associated with neither bronchoscopic experience (p = 0.71) nor the contours of the normal and the obstructed area provided by the system (p = 0.13). The precision of the SI by SENSA was 97.7% (95% CI: 92.4-103.7), which is significantly better than the precision of the SI by visual estimation (p < 0.001), with an improvement by at least 15%. Conclusion: SENSA provides objective SI measurements with a precision of up to 99.5%, which can be calculated from any bronchoscope using an affordable scalable interface. Providing normal and obstructed contours on bronchoscopic videos does not improve physicians' visual estimation of the SI.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN (up) Medium  
  Area Expedition Conference  
  Notes IAM; 600.075; 600.096; 600.145 Approved no  
  Call Number Admin @ si @ GOS2018 Serial 3043  
Permanent link to this record
 

 
Author Marta Diez-Ferrer; Debora Gil; Elena Carreño; Susana Padrones; Samantha Aso; Vanesa Vicens; Cubero Noelia; Rosa Lopez Lisbona; Carles Sanchez; Agnes Borras; Antoni Rosell edit  url
openurl 
  Title Positive Airway Pressure-Enhanced CT to Improve Virtual Bronchoscopic Navigation Type Journal Article
  Year 2016 Publication Chest Journal Abbreviated Journal CHEST  
  Volume 150 Issue 4 Pages 1003A  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN (up) Medium  
  Area Expedition Conference  
  Notes IAM; 600.096; 600.075 Approved no  
  Call Number Admin @ si @ DGC2016 Serial 3099  
Permanent link to this record
 

 
Author Esmitt Ramirez; Carles Sanchez; Agnes Borras; Marta Diez-Ferrer; Antoni Rosell; Debora Gil edit   pdf
url  openurl
  Title BronchoX: bronchoscopy exploration software for biopsy intervention planning Type Journal
  Year 2018 Publication Healthcare Technology Letters Abbreviated Journal HTL  
  Volume 5 Issue 5 Pages 177–182  
  Keywords  
  Abstract Virtual bronchoscopy (VB) is a non-invasive exploration tool for intervention planning and navigation of possible pulmonary lesions (PLs). A VB software involves the location of a PL and the calculation of a route, starting from the trachea, to reach it. The selection of a VB software might be a complex process, and there is no consensus in the community of medical software developers in which is the best-suited system to use or framework to choose. The authors present Bronchoscopy Exploration (BronchoX), a VB software to plan biopsy interventions that generate physician-readable instructions to reach the PLs. The authors’ solution is open source, multiplatform, and extensible for future functionalities, designed by their multidisciplinary research and development group. BronchoX is a compound of different algorithms for segmentation, visualisation, and navigation of the respiratory tract. Performed results are a focus on the test the effectiveness of their proposal as an exploration software, also to measure its accuracy as a guiding system to reach PLs. Then, 40 different virtual planning paths were created to guide physicians until distal bronchioles. These results provide a functional software for BronchoX and demonstrate how following simple instructions is possible to reach distal lesions from the trachea.  
  Address  
  Corporate Author rank (SJR) Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN (up) Medium  
  Area Expedition Conference  
  Notes IAM; 600.096; 600.075; 601.323; 601.337; 600.145 Approved no  
  Call Number Admin @ si @ RSB2018a Serial 3132  
Permanent link to this record
 

 
Author Debora Gil; Ruth Aris; Agnes Borras; Esmitt Ramirez; Rafael Sebastian; Mariano Vazquez edit   pdf
doi  openurl
  Title Influence of fiber connectivity in simulations of cardiac biomechanics Type Journal Article
  Year 2019 Publication International Journal of Computer Assisted Radiology and Surgery Abbreviated Journal IJCAR  
  Volume 14 Issue 1 Pages 63–72  
  Keywords Cardiac electromechanical simulations; Diffusion tensor imaging; Fiber connectivity  
  Abstract PURPOSE:
Personalized computational simulations of the heart could open up new improved approaches to diagnosis and surgery assistance systems. While it is fully recognized that myocardial fiber orientation is central for the construction of realistic computational models of cardiac electromechanics, the role of its overall architecture and connectivity remains unclear. Morphological studies show that the distribution of cardiac muscular fibers at the basal ring connects epicardium and endocardium. However, computational models simplify their distribution and disregard the basal loop. This work explores the influence in computational simulations of fiber distribution at different short-axis cuts.

METHODS:
We have used a highly parallelized computational solver to test different fiber models of ventricular muscular connectivity. We have considered two rule-based mathematical models and an own-designed method preserving basal connectivity as observed in experimental data. Simulated cardiac functional scores (rotation, torsion and longitudinal shortening) were compared to experimental healthy ranges using generalized models (rotation) and Mahalanobis distances (shortening, torsion).

RESULTS:
The probability of rotation was significantly lower for ruled-based models [95% CI (0.13, 0.20)] in comparison with experimental data [95% CI (0.23, 0.31)]. The Mahalanobis distance for experimental data was in the edge of the region enclosing 99% of the healthy population.

CONCLUSIONS:
Cardiac electromechanical simulations of the heart with fibers extracted from experimental data produce functional scores closer to healthy ranges than rule-based models disregarding architecture connectivity.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN (up) Medium  
  Area Expedition Conference  
  Notes IAM; 600.096; 601.323; 600.139; 600.145 Approved no  
  Call Number Admin @ si @ GAB2019a Serial 3133  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: