Francesco Ciompi, Oriol Pujol, Carlo Gatta, Marina Alberti, Simone Balocco, Xavier Carrillo, et al. (2012). HoliMab: A Holistic Approach for Media-Adventitia Border Detection in Intravascular Ultrasound. MIA - Medical Image Analysis, 16(6), 1085–1100.
Abstract: We present a fully automatic methodology for the detection of the Media-Adventitia border (MAb) in human coronary artery in Intravascular Ultrasound (IVUS) images. A robust border detection is achieved by means of a holistic interpretation of the detection problem where the target object, i.e. the media layer, is considered as part of the whole vessel in the image and all the relationships between tissues are learnt. A fairly general framework exploiting multi-class tissue characterization as well as contextual information on the morphology and the appearance of the tissues is presented. The methodology is (i) validated through an exhaustive comparison with both Inter-observer variability on two challenging databases and (ii) compared with state-of-the-art methods for the detection of the MAb in IVUS. The obtained averaged values for the mean radial distance and the percentage of area difference are 0.211 mm and 10.1%, respectively. The applicability of the proposed methodology to clinical practice is also discussed.
Keywords: Media–Adventitia border detection; Intravascular ultrasound; Multi-Scale Stacked Sequential Learning; Error-correcting output codes; Holistic segmentation
|
|
|
Debora Gil, & Petia Radeva. (2006). Inhibition of false landmarks. PRL - Pattern Recognition Letters, 27(9), 1022–1030.
Abstract: Corners and junctions are landmarks characterized by the lack of differentiability in the unit tangent to the image level curve. Detectors based on differential operators are not, by their own definition, the best posed as they require a higher degree of differentiability to yield a reliable response. We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our inhibition orientation energy (IOE) landmark locator.
|
|
|
Marina Alberti, Simone Balocco, Carlo Gatta, Francesco Ciompi, Oriol Pujol, Joana Silva, et al. (2012). Automatic Bifurcation Detection in Coronary IVUS Sequences. TBME - IEEE Transactions on Biomedical Engineering, 59(4), 1022–2031.
Abstract: In this paper, we present a fully automatic method which identifies every bifurcation in an intravascular ultrasound (IVUS) sequence, the corresponding frames, the angular orientation with respect to the IVUS acquisition, and the extension. This goal is reached using a two-level classification scheme: first, a classifier is applied to a set of textural features extracted from each image of a sequence. A comparison among three state-of-the-art discriminative classifiers (AdaBoost, random forest, and support vector machine) is performed to identify the most suitable method for the branching detection task. Second, the results are improved by exploiting contextual information using a multiscale stacked sequential learning scheme. The results are then successively refined using a-priori information about branching dimensions and geometry. The proposed approach provides a robust tool for the quick review of pullback sequences, facilitating the evaluation of the lesion at bifurcation sites. The proposed method reaches an F-Measure score of 86.35%, while the F-Measure scores for inter- and intraobserver variability are 71.63% and 76.18%, respectively. The obtained results are positive. Especially, considering the branching detection task is very challenging, due to high variability in bifurcation dimensions and appearance.
|
|
|
Alejandro Cartas, Juan Marin, Petia Radeva, & Mariella Dimiccoli. (2018). Batch-based activity recognition from egocentric photo-streams revisited. PAA - Pattern Analysis and Applications, 21(4), 953–965.
Abstract: Wearable cameras can gather large amounts of image data that provide rich visual information about the daily activities of the wearer. Motivated by the large number of health applications that could be enabled by the automatic recognition of daily activities, such as lifestyle characterization for habit improvement, context-aware personal assistance and tele-rehabilitation services, we propose a system to classify 21 daily activities from photo-streams acquired by a wearable photo-camera. Our approach combines the advantages of a late fusion ensemble strategy relying on convolutional neural networks at image level with the ability of recurrent neural networks to account for the temporal evolution of high-level features in photo-streams without relying on event boundaries. The proposed batch-based approach achieved an overall accuracy of 89.85%, outperforming state-of-the-art end-to-end methodologies. These results were achieved on a dataset consists of 44,902 egocentric pictures from three persons captured during 26 days in average.
Keywords: Egocentric vision; Lifelogging; Activity recognition; Deep learning; Recurrent neural networks
|
|
|
Fernando Vilariño, Ludmila I. Kuncheva, & Petia Radeva. (2006). ROC curves and video analysis optimization in intestinal capsule endoscopy. PRL - Pattern Recognition Letters, 27(8), 875–881.
Abstract: Wireless capsule endoscopy involves inspection of hours of video material by a highly qualified professional. Time episodes corresponding to intestinal contractions, which are of interest to the physician constitute about 1% of the video. The problem is to label automatically time episodes containing contractions so that only a fraction of the video needs inspection. As the classes of contraction and non-contraction images in the video are largely imbalanced, ROC curves are used to optimize the trade-off between false positive and false negative rates. Classifier ensemble methods and simple classifiers were examined. Our results reinforce the claims from recent literature that classifier ensemble methods specifically designed for imbalanced problems have substantial advantages over simple classifiers and standard classifier ensembles. By using ROC curves with the bagging ensemble method the inspection time can be drastically reduced at the expense of a small fraction of missed contractions.
Keywords: ROC curves; Classification; Classifiers ensemble; Detection of intestinal contractions; Imbalanced classes; Wireless capsule endoscopy
|
|