2008 |
|
Jaume Garcia, Debora Gil, Sandra Pujades, & Francesc Carreras. (2008). A Variational Framework for Assessment of the Left Ventricle Motion. International Journal Mathematical Modelling of Natural Phenomena, 3(6), 76–100.
Abstract: Impairment of left ventricular contractility due to cardiovascular diseases is reflected in left ventricle (LV) motion patterns. An abnormal change of torsion or long axis shortening LV values can help with the diagnosis and follow-up of LV dysfunction. Tagged Magnetic Resonance (TMR) is a widely spread medical imaging modality that allows estimation of the myocardial tissue local deformation. In this work, we introduce a novel variational framework for extracting the left ventricle dynamics from TMR sequences. A bi-dimensional representation space of TMR images given by Gabor filter banks is defined. Tracking of the phases of the Gabor response is combined using a variational framework which regularizes the deformation field just at areas where the Gabor amplitude drops, while restoring the underlying motion otherwise. The clinical applicability of the proposed method is illustrated by extracting normality models of the ventricular torsion from 19 healthy subjects.
Keywords: Key words: Left Ventricle Dynamics, Ventricular Torsion, Tagged Magnetic Resonance, Motion Tracking, Variational Framework, Gabor Transform.
|
|
|
Jaume Garcia, Debora Gil, Sandra Pujades, & Francesc Carreras. (2008). Valoracion de la Funcion del Ventriculo Izquierdo mediante Modelos Regionales Hiperparametricos. Revista Española de Cardiologia, 61(3), 79.
Abstract: La mayoría de la enfermedades cardiovasculares afectan a las propiedades contráctiles de la banda ventricular helicoidal. Esto se refleja en una variación del comportamiento normal de la función ventricular. Parámetros locales tales como los strains, o la deformación experimentada por el tejido, son indicadores capaces de detectar anomalías funcionales en territorios específicos. A menudo, dichos parámetros son considerados de forma separada. En este trabajo presentamos un marco computacional (el Dominio Paramétrico Normalizado, DPN) que permite integrarlos en hiperparámetros funcionales y estudiar sus rangos de normalidad. Dichos rangos permiten valorar de forma objetiva la función regional de cualquier nuevo paciente. Para ello, consideramos secuencias de resonancia magnética etiquetada a nivel basal, medio y apical. Los hiperparámetros se obtienen a partir del movimiento intramural del VI estimado mediante el método Harmonic Phase Flow. El DPN se define a partir de en una parametrización del Ventrículo Izquierdo (VI) en sus coordenadas radiales y circunferencial basada en criterios anatómicos. El paso de los hiperparámetros al DPN hace posible la comparación entre distintos pacientes. Los rangos de normalidad se definen mediante análisis estadístico de valores de voluntarios sanos en 45 regiones del DPN a lo largo de 9 fases sistólicas. Se ha usado un conjunto de 19 (14 H; E: 30.7±7.5) voluntarios sanos para crear los patrones de normalidad y se han validado usando 2 controles sanos y 3 pacientes afectados de contractilidad global reducida. Para los controles los resultados regionales se han ajustado dentro de la normalidad, mientras que para los pacientes se han obtenido valores anormales en las zonas descritas, localizando y cuantificando así el diagnóstico empírico.
|
|
2006 |
|
Debora Gil, & Petia Radeva. (2006). Inhibition of false landmarks. PRL - Pattern Recognition Letters, 27(9), 1022–1030.
Abstract: Corners and junctions are landmarks characterized by the lack of differentiability in the unit tangent to the image level curve. Detectors based on differential operators are not, by their own definition, the best posed as they require a higher degree of differentiability to yield a reliable response. We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our inhibition orientation energy (IOE) landmark locator.
|
|
|
Debora Gil, Aura Hernandez-Sabate, Oriol Rodriguez, J. Mauri, & Petia Radeva. (2006). Statistical Strategy for Anisotropic Adventitia Modelling in IVUS. IEEE Transactions on Medical Imaging, 25(6), 768–778.
Abstract: Vessel plaque assessment by analysis of intravascular ultrasound sequences is a useful tool for cardiac disease diagnosis and intervention. Manual detection of luminal (inner) and mediaadventitia (external) vessel borders is the main activity of physicians in the process of lumen narrowing (plaque) quantification. Difficult definition of vessel border descriptors, as well as, shades, artifacts, and blurred signal response due to ultrasound physical properties trouble automated adventitia segmentation. In order to efficiently approach such a complex problem, we propose blending advanced anisotropic filtering operators and statistical classification techniques into a vessel border modelling strategy. Our systematic statistical analysis shows that the reported adventitia detection achieves an accuracy in the range of interobserver variability regardless of plaque nature, vessel geometry, and incomplete vessel borders. Index Terms–-Anisotropic processing, intravascular ultrasound (IVUS), vessel border segmentation, vessel structure classification.
Keywords: Corners; T-junctions; Wavelets
|
|
|
Debora Gil, Jose Maria-Carazo, & Roberto Marabini. (2006). On the nature of 2D crystal unbending. Journal of Structural Biology, 156(3), 546–555.
Abstract: Crystal unbending, the process that aims to recover a perfect crystal from experimental data, is one of the more important steps in electron crystallography image processing. The unbending process involves three steps: estimation of the unit cell displacements from their ideal positions, extension of the deformation field to the whole image and transformation of the image in order to recover an ideal crystal. In this work, we present a systematic analysis of the second step oriented to address two issues. First, whether the unit cells remain undistorted and only the distance between them should be changed (rigid case) or should be modified with the same deformation suffered by the whole crystal (elastic case). Second, the performance of different extension algorithms (interpolation versus approximation) is explored. Our experiments show that there is no difference between elastic and rigid cases or among the extension algorithms. This implies that the deformation fields are constant over large areas. Furthermore, our results indicate that the main source of error is the transformation of the crystal image.
Keywords: Electron microscopy
|
|