2007 |
|
Jaume Amores, N. Sebe, & Petia Radeva. (2007). Context-Based Object-Class Recognition and Retrieval by Generalized Correlograms. IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 29(10):1818–1833, (ISI 3,81).
|
|
|
Jordi Vitria, M. Bressan, & Petia Radeva. (2007). Bayesian classification of cork stoppers using class-conditional independent component analysis. IEEE Transactions on Systems, Man and Cybernetics (Part C), 37(1): 32–38 (ISI 0,482).
|
|
|
Sergio Escalera, Oriol Pujol, & Petia Radeva. (2007). Boosted Landmarks of Contextual Descriptors and Forest-ECOC: a Novel Framework to Detect and Classify Objects in Cluttered Scenes.
|
|
2006 |
|
Debora Gil, & Petia Radeva. (2006). Inhibition of false landmarks. PRL - Pattern Recognition Letters, 27(9), 1022–1030.
Abstract: Corners and junctions are landmarks characterized by the lack of differentiability in the unit tangent to the image level curve. Detectors based on differential operators are not, by their own definition, the best posed as they require a higher degree of differentiability to yield a reliable response. We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our inhibition orientation energy (IOE) landmark locator.
|
|
|
Debora Gil, Aura Hernandez-Sabate, Oriol Rodriguez, J. Mauri, & Petia Radeva. (2006). Statistical Strategy for Anisotropic Adventitia Modelling in IVUS. IEEE Transactions on Medical Imaging, 25(6), 768–778.
Abstract: Vessel plaque assessment by analysis of intravascular ultrasound sequences is a useful tool for cardiac disease diagnosis and intervention. Manual detection of luminal (inner) and mediaadventitia (external) vessel borders is the main activity of physicians in the process of lumen narrowing (plaque) quantification. Difficult definition of vessel border descriptors, as well as, shades, artifacts, and blurred signal response due to ultrasound physical properties trouble automated adventitia segmentation. In order to efficiently approach such a complex problem, we propose blending advanced anisotropic filtering operators and statistical classification techniques into a vessel border modelling strategy. Our systematic statistical analysis shows that the reported adventitia detection achieves an accuracy in the range of interobserver variability regardless of plaque nature, vessel geometry, and incomplete vessel borders. Index Terms–-Anisotropic processing, intravascular ultrasound (IVUS), vessel border segmentation, vessel structure classification.
Keywords: Corners; T-junctions; Wavelets
|
|